Technical Design Proposal for a 30㎡×3m Class B Electromagnetic Shielding Room

Design Organization: Guangzhou Lain Intelligent System Development Co., Ltd.

Brand: KITOZER (开拓者)

Compilation Date: August 2026

—

Table of Contents

Chapter Content
——— ———
Chapter 1 Company Profile
Chapter 2 Project Overview
Chapter 3 User Requirements Analysis
Chapter 4 Design Description
Chapter 5 Detailed System Design & Product Technical Parameters
Chapter 6 Project Quotation & Configuration List
Chapter 7 Core Solution Advantages
Chapter 8 Technical Q&A (QA)
Chapter 9 Construction Schedule Plan
Chapter 10 Construction Organization Plan
Chapter 11 After-Sales Service System
Chapter 12 Operation & Maintenance Training Plan
Chapter 13 Typical Engineering Projects
Chapter 14 SEO Optimization System & Website Backend Configuration
Chapter 15 Contact Information

—

Chapter 1: Company Profile

1.1 Corporate Development Overview

Guangzhou Lain Intelligent System Development Co., Ltd. was established in 2002 and has been deeply engaged in the field of computer room construction and intelligent protection for over two decades. The company is a professional one-stop computer room solutions provider integrating R&D, production, sales, engineering implementation, and after-sales service into one comprehensive ecosystem.

Since its founding, the company has consistently focused on breakthrough innovations in electromagnetic shielding technology, modular computer room solutions, and intelligent environment monitoring systems. Through relentless technical advancement, the company has grown into a competitive source manufacturer (工厂源头生产企业) with core strengths in the domestic computer room construction sector.

Through more than twenty years of industry accumulation and technical expertise, the company has established a large-scale manufacturing base equipped with advanced CNC sheet metal processing equipment, automated painting production lines, and a dedicated shielding performance testing laboratory. The facility possesses an annual production capacity of hundreds of sets of various shielding rooms, integrated cabinets, and micro-module products. Our service network covers all provinces and municipalities across China, delivering thousands of computer room construction and renovation projects for government, military, scientific research, financial, and enterprise clients. Our stable product performance and reliable engineering quality have earned widespread market recognition.

1.2 Core Business Systems

The company’s core business revolves around the full lifecycle of computer room construction, forming four major product and service lines:

  • Turnkey Computer Room Engineering Services (机房工程总承包): Providing one-stop computer room construction services from solution design, manufacturing, on-site installation, to commissioning and acceptance — covering new construction and renovation projects for electromagnetic shielding rooms, IDC data centers, modular computer rooms, containerized computer rooms, and more.
  • Core Equipment R&D and Manufacturing: Producing proprietary KITOZER brand products, including various electromagnetic shielding cabinets, shielded desks, console workstations, integrated data cabinets, micro-module cold-aisle containment cabinets, outdoor weatherproof cabinets, etc. Custom non-standard solutions are fully supported.
  • Computer Room Environment Monitoring Systems: Offering comprehensive monitoring solutions covering temperature/humidity, water leakage, access control, video surveillance, fire protection, UPS, power distribution, and other critical parameters — enabling intelligent, unattended operation.
  • Technical Consulting & Maintenance Services: Providing shielding effectiveness testing, computer room performance evaluation, system upgrade solutions, and scheduled maintenance inspections to ensure long-term stable operation.

1.3 Brand & Qualifications

The company’s core brand, KITOZER, focuses on computer room equipment and shielding products, positioned as a provider of “efficient, green, innovative, and safe” computer room solutions. All products have passed multiple authoritative tests and comply with national and industry standards.

The company places high importance on technological R&D and intellectual property, holding multiple utility model patents and software copyrights. We have been certified as a High-Tech Enterprise (高新技术企业) and have established a comprehensive quality management system. All products and engineering projects strictly adhere to ISO9001 quality management standards. With exceptional product quality and professional service capabilities, the company has built a strong reputation and earned long-term cooperation and recognition from numerous clients worldwide.

1.4 Core Competitive Advantages

(1) Source Manufacturing — Controlled Quality

As a direct manufacturer (源头生产厂家), we operate our own production base with professional processing equipment. All core products are manufactured in-house with full quality control from raw material procurement to finished product delivery, ensuring stable and reliable performance. By eliminating intermediate supply chain layers, we deliver more cost-effective solutions to our clients.

(2) Customized Design — Perfectly Matched Solutions

Our engineering team tailors dedicated computer room solutions based on the client’s actual site conditions, shielding level requirements, equipment configuration, and budget. We provide three different design proposals free of charge for client selection, ensuring optimal alignment with individual needs.

(3) Professional Team — Extensive Experience

We maintain a professional technical team comprising electromagnetic shielding engineers, mechanical & electrical engineers, decoration engineers, and project managers. All core members possess 10+ years of industry experience and are highly proficient in the design and construction of various computer room types.

(4) Premium After-Sales — Comprehensive Support

A 7×24-hour professional online service system ensures rapid response to all client inquiries and after-sales needs. Each project is assigned a dedicated service manager responsible for the entire process — from initial consultation and construction management to ongoing operation and maintenance support.

—

Chapter 2: Project Overview

2.1 Project Background

With the rapid advancement of information technology, electronic information equipment has become widely used across all sectors, bringing electromagnetic information leakage and electromagnetic interference (EMI) issues into sharper focus. For applications involving classified information processing and precision electronic equipment operation, conventional computer rooms cannot meet electromagnetic protection requirements, exposing risks such as information leakage and equipment malfunction due to electromagnetic interference. Therefore, constructing a professional electromagnetic shielding room has become a critical security measure.

This project is designed to address the client’s actual operational needs by constructing a Class B compliant electromagnetic shielding room. The facility features a six-sided shielding enclosure with integrated filtering and grounding systems, creating a fully enclosed electromagnetic protection space. This structure serves two essential purposes: preventing the leakage of electromagnetic signals from internal classified equipment, and blocking external electromagnetic interference from affecting internal devices — ultimately safeguarding information security and equipment stability.

2.2 Basic Project Overview

This project involves the construction of a new electromagnetic shielding room with a net interior area of approximately 30㎡ and a net interior height of 3.0m. The room is designed in a conventional rectangular configuration (reference dimensions: 6m L × 5m W × 3m H). The construction scope includes the complete spectrum of systems: shielding enclosure structure, shielded doors and windows, ventilation waveguides, power filtering, signal filtering, grounding and equipotential bonding, interior finishing, fire protection, and security access control. Upon completion, the room will meet Class B electromagnetic shielding effectiveness requirements while providing a compliant operational environment for computer room applications.

2.3 Core Project Objectives

  • Electromagnetic Protection Objective: Achieve overall shielding effectiveness meeting Class B classified protection standards, with compliant shielding effectiveness indicators across the full frequency range of 14 kHz to 40 GHz, effectively suppressing electromagnetic leakage and external electromagnetic interference.
  • Environmental Adaptation Objective: Ensure the internal environment meets electronic equipment operational requirements, with illumination, temperature/humidity, cleanliness, and anti-static indicators conforming to national computer room design codes, providing a stable and reliable operating space.
  • Functional Completeness Objective: Integrate complete power distribution, signal transmission, fire protection, and access control systems to satisfy all daily operational requirements, with all through-wall cabling rigorously shielded to maintain overall shielding integrity.
  • Safety and Reliability Objective: Ensure overall structural safety and stability, with fire protection, grounding, and electrical safety indicators conforming to national codes. The system shall operate reliably with a long service life and easy maintenance.
  • Regulatory Compliance Objective: Execute all construction work in accordance with applicable process standards, pass third-party shielding effectiveness testing upon completion, and deliver complete engineering documentation with operation and maintenance manuals.

—

Chapter 3: User Requirements Analysis

3.1 Core Electromagnetic Shielding Requirements

  • The computer room shall achieve full-space electromagnetic shielding, with all six surfaces (walls, floor, and ceiling) providing continuous shielding performance with zero electromagnetic leakage points;
  • Shielding effectiveness shall meet Class B standards, satisfying the protection requirements for classified information equipment;
  • All pipelines entering or exiting the shielding room (power, signal, HVAC, fire protection, etc.) shall be processed with corresponding shielding and filtering measures without compromising overall shielding effectiveness;
  • Movable components such as shielded doors and observation windows shall provide shielding performance equivalent to the enclosure, maintaining stable shielding effectiveness after repeated opening and closing cycles.

3.2 Environmental Performance Requirements

  • Uniform internal illumination with an average illuminance of no less than 300 lux, meeting daily operations and equipment handling requirements;
  • Anti-static flooring with system resistance conforming to anti-static computer room codes, preventing static discharge damage to electronic equipment;
  • Wall and ceiling finishing materials shall possess fire-resistant, dust-proof, and moisture-proof properties in compliance with computer room cleanliness and fire safety standards;
  • Standard ventilation and air conditioning access provisions to maintain temperature and humidity within the optimal range for equipment operation.

3.3 Power Distribution & Signal Transmission Requirements

  • Three-phase 380V power supply input, with separate lighting circuits, equipment circuits, and maintenance/standby circuits inside the room for safe and reliable power distribution;
  • Gigabit network connectivity with physical separation between internal and external networks, ensuring transmission speed and information security;
  • Reserved interface provisions for telephone, CCTV video, USB peripherals, and other signal types to meet daily office and security requirements;
  • Power outlets evenly distributed across walls for equipment power supply and temporary power needs — all power distribution circuits shall be filtered.

3.4 Security Protection System Requirements

  • Equipped with a gas fire suppression system and smoke/heat detection devices for rapid fire response, utilizing residue-free extinguishing agents that will not damage electronic equipment;
  • Access control system at the room entrance for personnel entry/exit authorization management and entry log recording;
  • Complete equipotential grounding system with reliable grounding of both the shielding enclosure and internal equipment, with grounding resistance meeting code requirements for electrical safety and shielding performance;
  • Emergency lighting system that automatically activates upon power failure, ensuring safe personnel evacuation and emergency operation.

3.5 Construction & Delivery Requirements

  • Construction shall minimize structural damage to the existing building, with proper on-site protection of finished work and maintained site cleanliness;
  • Strict compliance with national construction codes and process standards for all workmanship, ensuring the quality of welding, sealing, installation, and other processes;
  • Reasonable construction schedule that prioritizes quality while accelerating progress to meet the project deadline;
  • Complete delivery of engineering documentation, product manuals, test reports, and operations manuals, together with operator training.

—

Chapter 4: Design Description

4.1 Applicable Standards & Codes

This proposal strictly complies with all relevant national laws, regulations, design codes, and industry standards, including but not limited to:

Standard Description
———- ————-
GB/T 50719-2011 Technical Code for Electromagnetic Shielding Room Engineering
BMB3-1999 Electromagnetic Leakage Emission Protection Requirements for Classified Information Equipment Usage Sites
BMB23-2019 Test Methods for Shielding Effectiveness of Electromagnetic Shielding Rooms
GB 50174-2017 Code for Design of Electronic Information System Computer Rooms
GB 50016-2014 (2018 Edition) Code for Fire Protection Design of Buildings
GB 50057-2010 Code for Design Protection of Structures Against Lightning
GB 50054-2011 Code for Design of Low-Voltage Electrical Installations
GB 50944-2013 Technical Code for Anti-Static Engineering
GB 50370-2005 Code for Design of Gas Fire Suppression Systems
GB 50311-2016 Code for Engineering Design of Generic Cabling Systems
JGJ/T 304-2013 Acceptance Code for Quality of Interior Decoration Engineering

4.2 Overall Design Principles

(1) Safety & Reliability First

Shielding performance and structural safety are prioritized above all else. All materials and equipment are selected from compliant, certified products with construction processes strictly following code requirements — ensuring long-term stable shielding effectiveness, secure structures, and full compliance of electrical and fire safety indicators.

(2) Advanced Technology

Mature and proven electromagnetic shielding technologies and computer room construction processes are employed, considering both current needs and future expansion requirements. The system is designed with scalability and adaptability to support subsequent equipment upgrades and functional expansion.

(3) Economic Efficiency

While meeting all performance requirements, the solution optimizes design and material selection to control construction costs — avoiding unnecessary over-specification while reducing lifecycle operational costs to achieve optimal value.

(4) Standardization

Overall design and construction follow national and industry standards, with standardized product interfaces, construction processes, and acceptance procedures. This ensures quality consistency and testability, facilitating future maintenance and renovation.

(5) Human-Centered Design

Full consideration is given to daily use and maintenance convenience, with rational placement of doors, windows, power outlets, switches, and access panels. Interior finishes are clean and aesthetically pleasing, creating a comfortable working environment.

4.3 Shielding Level Selection Description

In China, electromagnetic shielding rooms are classified into three grades — A, B, and C — each corresponding to different shielding effectiveness requirements and application scenarios:

Grade Typical Applications Shielding Requirements Cost Level
——- ——————— ———————- ————
C General confidentiality scenarios Lower shielding effectiveness Lower
B Classified information equipment (confidential level); most widely used in government, scientific research, and corporate R&D Moderate shielding effectiveness Moderate
A Top-secret and high-security scenarios Extremely high shielding effectiveness High

Based on the project’s actual usage requirements and the configuration standards of conventional classified computer rooms, this proposal selects Class B electromagnetic shielding, which fully satisfies the electromagnetic protection needs of most classified office, R&D, and data processing scenarios — offering an optimal balance of performance and cost with excellent practical value.

4.4 Overall System Architecture Design

This shielding room adopts a welded six-sided fully enclosed shielding enclosure as the primary structural system. Cold-rolled steel plates serve as the shielding panels, hot-dip galvanized square steel tubes form the support framework, and continuous full-penetration welding creates an electrically continuous shielding cavity. On this foundation, eight major systems work in coordination to form a complete shielding facility:

System Composition & Function
——– ———————-
Shielding Enclosure System Six-sided shielding steel plates (floor, walls, ceiling) with support framework — the core carrier of shielding performance
Shielded Door & Window System Personnel passage shielded door and shielded observation window meeting access and visual monitoring needs
Ventilation Waveguide System Honeycomb ventilation waveguide windows and various pipeline waveguides addressing ventilation, HVAC, and cable penetration shielding requirements
Power Filtering System Multi-level power filters treating incoming/outgoing power lines to prevent electromagnetic signal leakage along power cables
Signal Filtering System Various signal filters and fiber optic waveguides ensuring normal signal transmission while blocking electromagnetic leakage
Grounding & Equipotential System Grounding busbars and down conductors achieving equipotential bonding between shielding enclosure and internal equipment — guaranteeing shielding effectiveness and electrical safety
Interior Decoration System Anti-static flooring, painted steel panel walls, aluminum ceiling tiles optimizing the internal environment for operational requirements
Fire Protection & Security System Gas suppression, fire detection, and access control ensuring safe operation of the computer room

All systems operate in coordination to ensure both the continuity and reliability of overall electromagnetic shielding performance and the fulfillment of all functional requirements.

—

Chapter 5: Detailed System Design & Product Technical Parameters

5.1 Shielding Enclosure Main System

5.1.1 System Design Description

The shielding enclosure is the core structure of the entire shielding room. This proposal adopts a welded steel shielding enclosure composed of shielding steel plates and support framework. During construction, a hot-dip galvanized square steel framework is first erected within the building structure, followed by full-penetration welding of 2mm cold-rolled steel plates onto the framework. All plate seams are continuously welded, with beryllium copper conductive gaskets and conductive sealing compound providing supplementary sealing — ensuring complete electrical continuity with zero electromagnetic leakage points.

The enclosure covers the floor, four walls, and ceiling, forming a six-sided fully enclosed shielding space. An installation gap is reserved between the enclosure and the original building structure to prevent structural deformation from affecting shielding performance. The overall structure possesses sufficient strength and rigidity to bear its own weight and subsequent finishing and equipment installation loads — free from deformation or cracking over extended service life.

5.1.2 Shielding Main Steel Plate Technical Parameters

Parameter Specification
———– —————
Product Name Cold-Rolled Shielding Steel Plate for Electromagnetic Shielding Rooms
Material Grade Q235B High-Quality Carbon Structural Steel, Cold-Rolled
Nominal Thickness 2.0mm
Thickness Tolerance ±0.12mm
Standard Plate Size 1250mm (W) × 2500mm (L), custom cutting available per site conditions
Material Density 7.85 g/cm³
Tensile Strength 375 MPa ~ 500 MPa
Yield Strength ≥235 MPa
Elongation After Fracture ≥26%
Surface Roughness Ra ≤ 12.5 μm
Flatness Tolerance ≤5mm/m
Surface Conductivity Surface resistivity ≤ 0.1 Ω/square
Base Material Shielding Effectiveness ≥100dB (test range 10kHz ~ 40GHz)
Weldability Compatible with CO₂ gas-shielded welding and manual arc welding; weld tensile strength ≥90% of base material strength
Surface Treatment Factory-applied epoxy zinc-rich anti-rust primer, dry film thickness ≥40μm; after on-site welding, weld areas ground, derusted, and re-coated with anti-rust paint
Anti-Rust Service Life ≥15 years in indoor dry environment
Fire Performance Non-combustible, Class A per GB 8624-2012
Weight per Plate ≈49kg/sheet (1250×2500×2mm)
Installation Method Welded to support framework; continuous full-penetration welding between plates, weld height ≥3mm, no porosity, no cold welding, no discontinuities
Reference Standards GB/T 708-2019 (Dimension, Shape, Weight, and Tolerances of Cold-Rolled Steel Plates and Strips); GB/T 3274-2017 (Hot-Rolled Steel Plates and Strips of Carbon Structural Steels and Low-Alloy Structural Steels)
Environmental Adaptability Operating temperature -20℃ ~ +60℃; storage temperature -40℃ ~ +80℃; relative humidity ≤95% (non-condensing)
Application Scope Main shielding structure for Class B and Class C electromagnetic shielding rooms, shielded conference rooms, shielded test rooms

5.1.3 Shielding Support Framework Technical Parameters

Parameter Specification
———– —————
Product Name Hot-Dip Galvanized Square Steel Framework for Shielding Enclosure Support
Material Q235B Carbon Structural Steel, hot-dip galvanized surface treatment
Model/Specification 50mm × 50mm × 3mm (wall thickness)
Section Dimension Tolerance ±0.5mm
Wall Thickness Tolerance ±0.2mm
Galvanized Coating Thickness ≥85μm, compliant with hot-dip galvanizing anti-corrosion standards
Tensile Strength ≥375MPa
Yield Strength ≥235MPa
Bending Load Capacity Concentrated load capacity ≥5kN at 1m single-span
Anti-Corrosion Life ≥20 years in indoor environment
Layout Configuration Wall vertical channels at 600mm spacing; horizontal reinforcement channels at 1200mm spacing; ceiling main channels at 1000mm spacing, secondary channels at 600mm spacing; floor channels at 600mm spacing with added reinforcement
Connection Method Welded connections between channels; overall framework secured to building structure via expansion anchors with anti-rust treatment at connection points
Reference Standard GB/T 6728-2017 (Cold-Formed Steel Hollow Sections); GB/T 13912-2002 (Metallic Coatings — Hot-Dip Galvanized Coatings on Fabricated Iron and Steel Articles — Specification and Test Methods)
Function Support skeleton for shielding steel plates, ensuring structural strength and flatness, bearing loads from enclosure and finishing layers

5.1.4 Beryllium Copper Conductive Gasket Technical Parameters

Parameter Specification
———– —————
Product Name Beryllium Copper Conductive Gasket for Shielding Joints
Material Beryllium Bronze Alloy (QBe2)
Dimensions 10mm (width) × 2mm (thickness), custom lengths available
Beryllium Content 1.8% ~ 2.0%
Electrical Conductivity ≥22% IACS
Hardness HV 350 ~ 400 (after age hardening treatment)
Elastic Limit ≥700MPa
Contact Resistance ≤5mΩ/contact point
Shielding Effectiveness Contribution ≥30dB improvement at joints, ensuring continuity at gaps
Insertion/Withdrawal Cycles No significant increase in contact resistance after ≥10,000 cycles
Corrosion Resistance Excellent atmospheric corrosion resistance; no oxidation over extended indoor service
Operating Temperature Range -40℃ ~ +150℃
Installation Method Conductive adhesive bonding + rivet fastening; continuously applied along steel plate seams, shielded door frames, etc., ensuring full-surface contact
Reference Standard GB/T 31348-2014 (Beryllium Bronze Alloy)
Function Bridges shielding structure joints; ensures electrical continuity at gaps through elastic contact — a critical sealing element for overall shielding effectiveness

5.1.5 Two-Component Conductive Sealing Compound Technical Parameters

Parameter Specification
———– —————
Product Name Silver-Copper Filled Shielding-Grade Conductive Sealing Compound
Type Two-component, room-temperature curing
Filler Material Silver-copper alloy conductive filler
Volume Resistivity ≤0.01 Ω·cm
Shielding Effectiveness ≥60dB (10kHz ~ 10GHz band)
Curing Time 24 hours to full cure at room temperature; 2 hours initial set
Adhesive Strength Shear strength to steel ≥8MPa
Operating Temperature Range -55℃ ~ +120℃
Hardness (Shore D) 60 ~ 70
Elongation ≥150%
Aging Resistance ≥10 years service life in natural environment with no significant conductivity degradation
Environmental Compliance RoHS compliant; no hazardous volatile substances
Application Method Mix in specified ratio and apply to weld seams, holes, corners, and gaps; forms a continuous conductive seal after curing
Function Seals small gaps and openings in the shielding enclosure; provides both electrical continuity for shielding integrity and sealing for moisture protection

5.1.6 Welding & Anti-Rust Auxiliary Materials Technical Parameters

Material Key Specifications
———- ——————-
CO₂ Gas-Shielded Welding Wire Model: ER50-6; Diameter: 1.0mm; Tensile strength: ≥500MPa; Yield strength: ≥420MPa; Elongation: ≥22%; Features: good weld formation, low spatter, excellent weld mechanical properties, suitable for low-carbon steel
Epoxy Zinc-Rich Anti-Rust Primer Zinc content: ≥80% (dry film); Adhesion: Class 1; Salt spray resistance: ≥500 hours; Drying time: tack-free ≤30min, hard dry ≤24h; Function: long-term anti-rust protection for steel plates and welds
Auto Body Putty (Filler) Type: unsaturated polyester resin; Adhesion: strong bonding to steel; Sandability: excellent, easy to sand smooth after curing; Function: fills weld irregularities for a flat enclosure surface, ready for finishing work

5.2 Shielded Door & Window System

5.2.1 System Design Description

Shielded doors and windows are the movable components of a shielding room and represent the most vulnerable points in shielding integrity. Professional electromagnetic shielded door and window products are therefore essential. This proposal includes 1 set of manual swing-type shielded door serving as the main personnel entrance and 1 shielded observation window for internal/external viewing. Both feature full-perimeter beryllium copper gasket sealing structures, ensuring shielding effectiveness consistent with the enclosure while providing smooth operation and excellent durability.