ToggleKITOZER 30m² Class C EMI Shielded Server Room System Design & Configuration
Model: KTR-SH-C30 Series | Application: Secure server room / EMC testing / sensitive equipment chamber | Updated: 2026
Product Overview
The KITOZER KTR-SH-C30 is a pre-engineered 30m² Class C EMI shielded server room solution developed by Guangzhou Lai’an Intelligent System Development Co., Ltd. for sensitive IT equipment, electronic equipment testing and financial data backup rooms. Built around a six-face welded steel Faraday cage, the integrated package includes line filters, a shielded door, precision air conditioning, clean-agent fire suppression and a dynamic environment monitoring (DEM) system.
The room is designed at 6.9 m × 4.3 m × 4.3 m, providing roughly 29.67 m² of usable floor area and space for eight 42U racks, two N+1 precision air-conditioning units and one new mains distribution panel. The shell is fully CO₂-welded from Q235B cold-rolled steel (3 mm floor, 2 mm walls and ceiling) and finished with epoxy zinc-rich primer for a design service life of at least 50 years.
Measured shielding performance meets both GJBz20219-94 Class C and BMB3-1999 Class C criteria: ≥70 dB at 14 kHz magnetic field, ≥100 dB at 50 MHz–1 GHz plane wave, and ≥100 dB at 1–10 GHz microwave. Independent third-party shielding-effectiveness testing is supported at handover.
Key Features
Six-face welded shell. The floor frame, wall panels and ceiling are continuously welded with no seams left open, giving 100% electrical continuity across the cage.
Every penetration filtered or waveguide-treated. A 380 V / 100 A mains filter, RJ45 and RS485 signal filters, fiber-optic waveguide tubes, water-service waveguide tubes and hexagonal honeycomb vent panels ensure no line-in or line-out path leaks RF energy.
Manual shielded door. A 900 × 2000 mm single-leaf door with 80 mm thick leaf and beryllium-copper/silicone composite fingerstock delivers ≥100 dB shielding across the whole band and ≥100,000 open-close cycles.
Closed-loop temperature and humidity. Two 12.5 kW air-cooled precision units run N+1 with ±0.5 °C / ±3% RH control, supported by a 300 m³/h enthalpy-recovery fresh-air unit that maintains ≥5 Pa positive pressure and filters PM2.5.
Clean-agent fire suppression. A 90 L HFC-227ea cylinder charged with 90 kg agent gives an 8.5% design concentration and ≤10 s discharge, paired with photoelectric smoke and rate-of-rise heat detectors.
Technical Specifications
| Item | Value | Note |
|---|---|---|
| Net room size | 6.9 m × 4.3 m × 4.3 m | ≈29.67 m² floor |
| Shielding class | GJBz20219-94 C / BMB3-1999 C | Dual standard |
| Shielding at 14 kHz (mag.) | ≥70 dB | Low frequency |
| Shielding 50 MHz–1 GHz | ≥100 dB | Plane wave |
| Shielding 1–10 GHz | ≥100 dB | Microwave |
| Steel thickness | 3 mm floor / 2 mm walls & ceiling | SPCC fully welded |
| Precision air conditioning | 12.5 kW × 2 (N+1) | ±0.5 °C / ±3% RH |
| Fire suppression | HFC-227ea 90 L / 90 kg | Discharge ≤10 s |
| Rack capacity | 42U × 8 | 600 × 1000 × 2000 mm |
| Grounding resistance | ≤1 Ω | Separated logic & protective |
| Seismic rating | Grade 7 | Load spreaders ≥1000 kg/m² |
| Ambient set-point | 22 ± 2 °C / 50 ± 5% RH | Positive pressure ≥5 Pa |
Configuration & Reference Price
| Subsystem | Scope | Reference price (incl. tax & freight) |
|---|---|---|
| Shielded shell | Frame + steel plates + welding + anti-rust, 157 m² | ¥320,000 – ¥380,000 |
| Shielded door & filters | 1 manual door, mains/signal/fiber waveguides | ¥85,000 – ¥110,000 |
| Power & lighting | Mains panel, LED panels, PDU, service sockets | ¥28,000 – ¥38,000 |
| Interior finish | Aluminum ceiling, rock-wool wall panels, anti-static floor | ¥45,000 – ¥60,000 |
| Clean-agent fire system | Cylinder, agent, detectors, control panel | ¥55,000 – ¥75,000 |
| Precision air conditioning | 12.5 kW air-cooled × 2, piping & vibration isolators | ¥90,000 – ¥120,000 |
| Racks & grounding | 42U × 8, copper busbars, load spreaders | ¥60,000 – ¥80,000 |
| DEM system | Controller + touchscreen + sensors + access control + CCTV | ¥55,000 – ¥75,000 |
| Cabling | CAT6, single-mode fiber, ODF, patch panels | ¥20,000 – ¥30,000 |
| Fresh air & structural reinforcement | Enthalpy-recovery unit, spreaders, relief damper, exhaust fan | ¥35,000 – ¥50,000 |
| Room total (reference) | ¥793,000 – ¥1,018,000 | |
In USD, this is approximately US$110,000 – US$141,000. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY). Prices are for reference only; actual quotation may vary depending on site conditions, door type, AC brand, local fire-code acceptance and shipping distance.
Applications
- High-security server rooms and secure equipment rooms for government and large enterprises;
- Near-field test chambers for electronic-warfare, radar and radio equipment;
- Core data backup and encrypted compute nodes for finance and energy operators;
- EMC pre-compliance rooms and EMI isolation chambers for SEM/TEM and MRI instruments;
- Command-and-communication and digital-archive rooms for public-security and tax agencies.
Installation & Maintenance Notes
Typical schedule. About 60 days on site: 12 days for shell welding and seam inspection, 25 days for M&E installation, 10 days for commissioning and third-party testing.
- Test the insulation mat and steel frame (≥10¹² Ω) before any welding starts;
- Install every filter and waveguide before closing the panels — do not drill through finished shielding;
- Re-measure door-seam shielding after installation; set fingerstock compression at 30%–40%;
- Run the HFC-227ea discharge test before IT equipment is moved in;
- Repeat shielding-effectiveness testing annually; inspect gaskets, grounding and filter temperature quarterly.
Acceptance & Warranty
Handover follows GB/T 12190-2021 shielding-effectiveness measurement. A third-party lab measures shielding performance at the low-frequency (14 kHz magnetic), plane-wave (50 MHz–1 GHz) and microwave (1–10 GHz) bands; all three must meet the declared ≥70 / ≥100 / ≥100 dB thresholds. As-built drawings, weld inspection records, filter certificates, fire-system test reports and the test lab report are handed over together with the O&M manual. The standard warranty is two years on the whole room and three years on the core equipment (shell, AC, DEM); annual re-testing of shielding performance is recommended and included in the first-year service package. Spare fingerstock, gaskets and filter cartridges are recommended as on-site consumables.
[Product render location: KTR-SH-C30 room exterior / shielded door close-up / welded seam / DEM touchscreen UI]
Keywords: EMI shielded room, Class C shielded server room, Faraday cage chamber, RF shielding room, EMC shielded enclosure, shielded door, EMI filter wall plate, KITOZER shielded room, Guangzhou Lai’an
Meta Title: KITOZER 30m² Class C EMI Shielded Server Room System Design & Configuration
Meta Description: KITOZER KTR-SH-C30 30m² Class C EMI shielded server room with welded Faraday cage, filtered penetrations, shielded door, precision AC, HFC-227ea fire suppression and DEM. Reference configuration & price.
Meta Keywords: EMI shielded room, shielded server room, Faraday cage, RF shielding, EMC chamber, KITOZER KTR-SH-C30, Class C shielding
Contact: Guangzhou Lai’an Intelligent System Development Co., Ltd. | Tel/WhatsApp: +86 18520668845 | Web: gdlain.com | Address: Zhongrun Industrial Park, Shilou, Panyu, Guangzhou, China