KITOZER Modular Cold Aisle Containment System for Data Centers





KITOZER Modular Cold Aisle Containment System for Data Centers



KITOZER Modular Cold Aisle Containment System for Data Centers

Model: KTR-CA Series | Standard aisle width 1200 mm | New build & retrofit ready

Overview

The KITOZER KTR-CA modular cold aisle containment system is a standardized airflow-management product developed by Guangzhou Lai’an Intelligent System Development Co., Ltd. to solve hot-cold air mixing, local hot spots and high PUE in data centers. The cold aisle between two rows of racks is fully enclosed on top and at both ends, forcing CRAH-supplied cold air to travel vertically up the aisle and into server intakes instead of mixing with hot exhaust at rack top.

All components are factory pre-fabricated and bolted on site. Columns, beams, top rails, side panels, skylights and doors are modular and fit 600 mm or 800 mm wide standard 19-inch racks. Single-row and double-row layouts are both supported. The system is pre-wired for fire linkage: on a fire alarm signal, every flip skylight opens within 3 seconds so gaseous fire suppression can flood the room quickly.

Structure & Components

  • Containment frame: anodized 6063-T5 aluminum columns, cross beams and top rails; verticality ≤1 mm/m.
  • Aisle doors: sliding, hinged or automatic sensor doors (optional), with limit stops, locks and anti-pinch safety; manual release on power loss.
  • Skylights: fixed, flip or fire-linked; opening angle ≥90°; fire release within 3 s.
  • Airflow management: blanking panels, rack side panels and under-floor baffles eliminate short-circuit paths.
  • Lighting: LED strips ≥300 lux with motion sensors; emergency battery ≥30 min.
  • Fire linkage: smoke/heat detectors ≤6 m spacing, sounder-strobe, damper release actuators; dedicated power supply.
  • Monitoring: temperature/humidity and differential-pressure sensors, access control and optional CCTV; RS485 upload.
  • Control cabinet: local touchscreen, remote SNMP/Modbus interface; grounding ≤4 Ω.

Key Features

30%+ cooling efficiency gain. Once the cold aisle is sealed, the same IT load requires fewer CRAH units or higher supply temperature, typically reducing PUE by 0.1–0.2.

Reliable fire linkage. Electromagnetic release or electric actuators open all flip skylights within 3 s of a fire alarm; three consecutive tests must pass before handover.

Retrofit-friendly. Bolted construction avoids welding and does not drill through the raised floor. A 20 m aisle can be assembled by 2–3 workers in 1–2 days.

Smart interlock. Differential-pressure sensors alarm when cold-aisle positive pressure drops below 5 Pa; lights switch off on exit; access control unlocks on fire alarm.

Technical Specifications

Item Value
Standard aisle width 1200 mm (1100 / 1300 mm optional)
Rack width compatibility 600 / 800 mm 19-inch
Frame material 6063-T5 anodized aluminum
Skylight glass 5 mm tempered, black-frit edge
Door glass 8 mm tempered in aluminum frame
Gasket EPDM foam, compression set ≤10%
Cold-aisle positive pressure 5–10 Pa
Vertical temperature spread ≤2 °C
Cooling efficiency improvement ≥30% vs. open aisle
Emergency lighting duration ≥30 min
Fire-linkage response All skylights open ≤3 s
Grounding resistance ≤4 Ω

Configuration & Reference Price

Reference scope for a 20 m long, 10-rack cold-aisle project:

Item Qty Reference price (incl. tax & freight)
Frame (columns/beams/top rails/side panels) 20 m ¥36,000 – ¥45,000
Flip skylights (with release actuators) ≈14 m² ¥18,000 – ¥24,000
Sliding doors at both ends 2 leaves ¥9,000 – ¥12,000
LED strips + emergency lights + sensors 1 set ¥4,500 – ¥6,000
Fire-linkage panel + detectors + sounder 1 set ¥7,500 – ¥10,000
T/H & pressure sensors + control cabinet 1 set ¥8,000 – ¥11,000
Blanking panels, side panels, floor baffles 1 batch ¥3,500 – ¥5,000
Total per aisle ¥86,500 – ¥113,000

In USD, approximately US$12,000 – US$15,700. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY). Prices are for reference only; actual quotation may vary by aisle length, door type, optional CCTV/access control and site conditions.

Deployment & Commissioning Notes

Before installation, verify floor flatness ≤2 mm/m, floor load ≥600 kg/m² and that the raised floor is complete. The build sequence is: setting-out → rack alignment & interlocking → column base fixing → beams & top rails → side panels & gaskets → doors → skylights & release actuators → wiring of lighting/fire/monitoring → integrated commissioning.

Four acceptance checks matter most: insulation resistance ≥0.5 MΩ, grounding ≤4 Ω, three consecutive fire-linkage tests with all skylights opening within 3 s, and stable 5–10 Pa cold-aisle positive pressure with vertical spread ≤2 °C.

Maintenance Schedule

Daily checks cover alarm status on the touchscreen, door closure and T/H values. Weekly checks cover fasteners, skylight hinges and door rolling noise, plus cleaning of aisle debris. Monthly checks cover electrical terminations, a manual fire-release test and calibration of T/H and differential-pressure sensors. Quarterly work covers lubrication of hinges and door rollers, gasket inspection, emergency-light discharge time and grounding resistance. An annual full service includes a complete fire-linkage test, sensor recalibration and a software upgrade on the control cabinet. Most consumables — gaskets, LED strips, filters — are standard parts stocked by KITOZER service partners.

KITOZER supports single-row and double-row layouts, custom aisle widths, and integration with third-party BMS / DCIM platforms via Modbus TCP or SNMP. Field retrofit teams can complete a typical 20 m aisle in 1–2 working days without interrupting adjacent IT load.

KITOZER KTR-CA modular cold aisle containment in data center
[Render location: aisle overview / flip skylight open / sliding door closed / touchscreen pressure UI]

Keywords: cold aisle containment, hot aisle containment, data center airflow management, fire-rated drop-down ceiling, flip skylight, modular cold aisle, PUE reduction, KITOZER KTR-CA

Meta Title: KITOZER Modular Cold Aisle Containment System for Data Centers

Meta Description: KITOZER KTR-CA modular cold aisle containment with fixed/flip/fire-linked skylights, sliding doors, LED lighting and differential-pressure monitoring. 30% cooling efficiency gain, 3 s fire release.

Meta Keywords: cold aisle containment, hot aisle containment, data center airflow, fire-rated skylight, modular containment, KITOZER

Contact: Guangzhou Lai’an Intelligent System Development Co., Ltd. | Tel/WhatsApp: +86 18520668845 | Web: gdlain.com | Address: Zhongrun Industrial Park, Shilou, Panyu, Guangzhou, China


Shopping Cart