KITOZER KTR-SPD34 Network Signal Surge Protector (RJ45 Gigabit)

KITOZER KTR-SPD34 Network Signal Surge Protector (RJ45 Gigabit)

Brand: KITOZER Series: KTR-SPD34 Category: Data Center Engineering / Lightning & Grounding

RJ45gigabit networksignal surgePoE compatibleKTR-SPD34

1. Overview

The KITOZER KTR-SPD34 is an RJ45 network signal surge protector (SPD), installed in series between a switch and cameras, APs or servers to divert transient over-voltage induced by lightning, switching or static on data lines. SPD34 supports gigabit (1000 Mbps), is PoE (802.3af/at) compatible, with 10 kA discharge (8/20 μs) and ≤800 V voltage protection level, effectively shielding downstream network ports.

Inside, the SPD34 uses a GDT + TVS + PTC multi-stage circuit: common-mode surge hits the GDT first for bulk current, differential-mode surge is clamped fast by TVS, and a PTC fuse disconnects on downstream short. RJ45 follows T568B: 1/2 and 3/6 carry data, 4/5 and 7/8 carry PoE; every pair is surge-protected without affecting data or power.

The SPD34 housing is die-cast aluminum, 35 mm DIN rail mount, with RJ45 ports on both ends and a ground lead (6 mm² yellow-green) to the room grounding bar. Response ≤1 ns, insertion loss ≤0.5 dB, 1 GHz bandwidth, supporting gigabit and even 2.5G/5G. For outdoor cameras, APs and intercoms fed over long UTP runs, the cable itself is a lightning entry point; the SPD34 is the last line defense at the line end, working with power SPD and equipotential grounding to form the room protection system.

2. Key Features

Gigabit PoE compatible

  • 1000 Mbps.
  • 802.3af/at PoE.
  • 1 GHz bandwidth.
  • IL ≤0.5 dB.

Multi-stage circuit

  • GDT gas tube.
  • TVS fast clamp.
  • PTC resettable fuse.
  • Response ≤1 ns.

10 kA discharge

  • 8/20 μs 10 kA.
  • Vp ≤800 V.
  • Per-pair protection.
  • Common/differential mode.

DIN rail mount

  • Die-cast Al housing.
  • 35 mm DIN.
  • RJ45 both ends.
  • 6 mm² ground terminal.

3. Specifications

Item Parameter
Model KTR-SPD34
Interface RJ45 (in/out)
Speed 1000 Mbps (2.5G compatible)
Bandwidth 1 GHz
Discharge 10 kA (8/20 μs)
Vp ≤800 V
Response ≤1 ns
PoE 802.3af/at
Insertion loss ≤0.5 dB
Ground lead 6 mm² yellow-green
Mounting 35 mm DIN rail
Operating temp -40~85℃

4. Reference Prices

KTR-SPD34 RJ45 network SPD (gigabit): Reference USD 11~25 / pc (ref. CNY 80~180 at ~7.2)

KTR-SPD34 24-port patch panel integrated SPD: Reference USD 83~167 / unit (ref. CNY 600~1200 at ~7.2)

KTR-SPD34 ground cable (opt.): Reference USD 1.4~4.2 / pc (ref. CNY 10~30 at ~7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Switch/camera line protection.
  • Outdoor AP / wireless bridge.
  • Intercom / access UTP.
  • Room server port protection.
  • Long PoE runs.

6. Installation & Maintenance

Installation

  • Wire SPD in series before protected device.
  • IN from outdoor line.
  • OUT to indoor device.
  • Clip to 35 mm DIN rail.
  • Ground to room bar.
  • T568B wiring.

Maintenance

  • Test before storm season annually.
  • Check status after strike.
  • Tighten ground lead.
  • Replace SPD when degraded.
  • Do not bypass SPD.
  • Keep ground resistance ≤4 Ω.

7. FAQ

  • Q:Where to install SPD — switch or camera end?
    A:Install near the protected device. For outdoor cameras, place SPD at the camera end or room incoming end. Keep the SPD-to-device cable as short as possible.
  • Q:Does SPD slow down the network?
    A:Gigabit SPD at 1 GHz bandwidth and ≤0.5 dB IL has no impact. Cheap SPDs may use crossed wiring causing speed negotiation drops; KTR-SPD34 uses straight-through wiring.
  • Q:Can PoE pass through SPD?
    A:KTR-SPD34 is 802.3af/at compatible, pins 4/5 and 7/8 straight through. Note PoE power capacity (usually ≤60 W); for PoE++ (90 W) use a dedicated model.
  • Q:How often to replace SPD?
    A:SPD is consumable; each strike degrades it. If the status window turns red, replace. Without a window, replace every 3~5 years or after a strike test.

8. Trend & Selection

Signal SPD is moving toward integration (patch-panel integrated), smart monitoring (remote degradation reporting) and higher speed (10G/25G). Select by line type (UTP/fiber/video/control), speed, PoE power and discharge rating. Room protection needs three-stage coordination: main distribution SPD → floor SPD → device-end SPD, with equipotential grounding.

9. Delivery & Service

KITOZER sizes KTR-SPD34 SPD quantity by line count and speed, providing surge wiring and equipotential bonding diagrams. Delivery includes SPD body, DIN clip, ground lead and certificates. Warranty covers strike testing and degradation assessment.

10. Additional Notes

A common pitfall is installing only power SPD and ignoring signal SPD. Lightning induction enters mainly through data lines (UTP, video, control); power SPD cannot protect network ports. Outdoor lines need signal SPD.

Another pitfall is long or coiled SPD ground leads. Keep the SPD ground lead short and straight (≤0.5 m); lead inductance raises residual voltage and weakens protection. Bond directly to the nearest equipotential bar.

Selection summary: RJ45 gigabit; 10 kA discharge; PoE compatible; DIN rail; response ≤1 ns. The signal SPD is the last line of defense at the line end — right location, proper grounding, periodic testing keep room network devices safe through storm season.