KITOZER KTR-FTB24 24-port SC Fiber Termination Box (Wall/Rack)

KITOZER KTR-FTB24 24-port SC Fiber Termination Box (Wall/Rack)

Brand: KITOZER Series: KTR-FTB24 Category: Fiber Cabling / Fiber Termination Box

24-port SCwall/rack24-fiber splicecold-rolled steelKTR-FTB24

1. Overview

The KITOZER KTR-FTB24 is a 24-port SC fiber termination box (patch box) for end-of-cable splicing, pigtail fixation and adapterLead Out. Cold-rolled steel (1.2 mm), electrostatic powder coating, wall-mount or 19-inch rack dual-use. Internal flip splice tray, adapter strip, pigtail posts, cable lock. For FTTH building distribution, room ODF end and campus fiber cross-connect.

KTR-FTB24 full-config 24 fibers (12 SC duplex adapters), splices 24 pigtails to the cable, patchcords connect via adapters. Splice tray capacity 24 fibers (expandable to 48 with stacking). Cable enters from bottom, locked (tensile ≥50 N); pigtails coiled in tray (bend radius ≥40 mm). Adapter panel is removable for splicing.

Typical uses: building telecom room fiber distribution (one FTB24 per floor); room ODF end (backbone cable spliced to box, patchcord to switch); residential FTTH split box; campus fiber cross-connect point.

2. Key Features

24-port SC

  • 12 SC duplex adapters.
  • 24 fibers full.
  • Expandable 48.
  • UPC/APC option.

Dual mount

  • Wall-mount.
  • 19-inch rack.
  • Mounting ears.
  • Cold-rolled steel.

Splice tray

  • Flip splice tray.
  • Splice sleeve storage.
  • Pigtail coil ≥40 mm.
  • Removable panel.

Cable lock

  • Bottom cable entry.
  • Tensile ≥50 N.
  • Pigtail posts.
  • Ground terminal.

3. Specifications

Item Parameter
Model KTR-FTB24
Ports 24 (12 SC duplex)
Adapter type SC single/multi mode optional
Splice capacity 24 fibers (expandable 48)
Housing Cold-rolled steel 1.2 mm
Finish Powder coat (black)
Mounting Wall / 19-inch rack
Cable entry Bottom (2~4 ports)
Tensile ≥50 N (cable lock)
Dimensions ~482×1U (rack) / 450×150×100 mm (wall)
Operating temp -10~60℃

4. Reference Prices

KTR-FTB24 24-port SC box (empty):Ref. USD 14~28 / unit (CNY 100~200 @7.2)

KTR-FTB24 full-config (24 SC adapters + pigtails):Ref. USD 28~49 / unit (CNY 200~350 @7.2)

KTR-FTB24 48-port version:Ref. USD 35~62 / unit (CNY 250~450 @7.2)

Splice sleeves (100 pcs):Ref. USD 3~6 / pack (CNY 20~40 @7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Building telecom room distribution.
  • Room ODF end.
  • Residential FTTH split.
  • Campus fiber cross-connect.
  • Industrial fiber link.

6. Installation & Maintenance

Installation

  • Fix box (wall/rack).
  • Cable enters bottom entry.
  • Strip outer jacket, expose 24 fibers.
  • Lock cable (tensile).
  • Splice each fiber to pigtail.
  • Place sleeve in tray.
  • Coil pigtail (bend ≥40 mm).
  • Insert pigtail connector into adapter.
  • Close panel, label.

Maintenance

  • Inspect adapter end-face periodically.
  • Clean fiber connectors.
  • Check cable lock.
  • Update labels.
  • Optical power test link.
  • OTDR locate splice fault.

7. FAQ

  • Q:Termination box vs ODF?
    A:A termination box (FTB) is small (24~48 ports) for end splicing and patching; an ODF (fiber distribution frame) is large (96~288 ports) for central backbone distribution in the room. FTB is miniaturized ODF, located in building telecom rooms or room edge; ODF is in the main distribution area.
  • Q:How many fibers for 24 ports?
    A:24 SC duplex ports (12 adapters) correspond to 24 fibers: one 24-fiber cable in, each fiber spliced to a pigtail, pigtail connector into adapter. With duplex patchcords (Tx/Rx), 12 duplex adapters = 12 duplex links (24 fibers). Choose cable count (12/24/48) accordingly.
  • Q:How to fix splice points in the box?
    A:Splice points (fiber-to-pigtail joints) are protected by heat-shrink sleeves (with steel pin). Sleeves go into the splice tray slots — notSuspended. Pigtail slack ≥1 m coiled in tray, bend radius ≥40 mm. Splices must not be under tension (cable lock bears the pull), otherwise loss increases or fiber breaks.
  • Q:UPC vs APC adapters?
    A:Data comm (Ethernet, storage) uses UPC (beige); CATV/PON/broadcast uses APC (green, higher return loss). UPC and APC must not be mated (end-face damage). If both UPC and APC on the same box panel, zone them and label clearly to prevent wrong insertion.

8. Trend & Selection

Fiber termination boxes are trending high-density (MTP/MPO backbone + LC branch), modular (pluggable cassettes) and smart (fiber ID and optical power monitoring). High-density data centers use MPO backbone boxes; building cabling still mainly uses SC/LC termination boxes.

9. Delivery & Service

KITOZER sizes KTR-FTB24 by cable count and port type, providing splicing drawings and label templates. Delivery includes box, adapters (optional), pigtails (optional), splice tray, certificate. Warranty covers splicing guidance and OTDR test support.

10. Additional Notes

A common pitfall is not locking the cable. After the cable enters the box, the outer jacket and strength member must be locked (clamp) to bear tension. If the cable only passes through the entry without locking, external pull transfers directly to splice points, breaking fibers. After locking, the strength member (metal or aramid) must also be fixed to the ground post.

Another pitfall is pigtail coil radius too small. Coiling pigtails in the tray at a radius <40 mm causes macro-bending loss, dropping link power. The tray has dedicated spiral grooves — coil along the groove, do not fold or over-tie.

Selection summary: 24-port SC; wall/rack; 24-fiber splice; cold-rolled steel; removable adapters. The termination box is the cable’s terminal station — cable lock, splice protection, pigtail coil, clear labels, keeps fiber links reliable.