Brand: KITOZER Series: KTR-ENVCO2 Category: Environmental Monitoring / CO2 Sensor
NDIRCO2 0~5000ppmRS485 Modbustemp+humidityKTR-ENVCO2
1. Overview
The KITOZER KTR-ENVCO2 is a carbon dioxide sensor using NDIR non-dispersive infrared principle to measure ambient CO2 concentration, range 0 to 5000 ppm, accuracy plus or minus (50 ppm plus 3 percent reading). It also integrates temperature and humidity, reporting three parameters via RS485 Modbus-RTU to the EMCS platform. NDIR provides long life over 10 years and immunity to interference, suited for indoor air quality monitoring in rooms, offices, meeting rooms and classrooms.
KTR-ENVCO2 powered DC12 V, RS485 communication at 9600 to 115200 bps (default 9600). Front panel LCD shows real-time CO2 ppm, temperature and humidity; tri-color LED (green below 800 ppm normal, yellow 800 to 1500 ppm elevated, red above 1500 ppm high). ABS wall-mount housing about 110 by 80 by 30 mm. Calibration button with automatic baseline correction ABC.
Typical uses: room air quality monitoring (dense occupancy ventilation); office CO2 linked to fresh-air; classroom air quality; meeting room ventilation control; warehouse and archive temp/humidity plus CO2. CO2 reflects indoor ventilation; above 1500 ppm people feel drowsy and fresh air is needed.
2. Key Features
NDIR principle
- Non-dispersive infrared absorption.
- Range 0 to 5000 ppm.
- Accuracy plus or minus (50 ppm plus 3 percent).
- Life over 10 years.
Three-in-one
- CO2 concentration.
- Temperature.
- Humidity.
- LCD real-time display.
RS485 Modbus
- Modbus-RTU.
- 9600 to 115200 bps.
- Status and parameter report.
- Up to 32 per bus.
LED indicator
- Tri-color LED green/yellow/red.
- Calibration button.
- Automatic baseline correction ABC.
- DC12 V power.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-ENVCO2 |
| Measurement principle | NDIR非色散红外 |
| CO2 range | 0~5000ppm |
| CO2 accuracy | ±(50ppm+3%读数) |
| Temp range | 0~50℃(±0.5℃) |
| Humidity range | 0~95%RH(±3%) |
| Protocol | RS485 Modbus-RTU |
| Baud rate | 9600~115200bps(默认9600) |
| Power supply | DC12V |
| Power draw | ≤1.5W |
| Display | LCD+三色LED |
| Calibration | 自动ABC基准校准 |
| 外壳 | ABS壁挂 |
| 尺寸 | 约110×80×30mm |
4. Reference Prices
KTR-ENVCO2 CO2 sensor (3-in-1):Ref. USD 56~97 / pc (CNY 400~700 at 7.2)
KTR-ENVCO2 CO2-only economy:Ref. USD 35~56 / pc (CNY 250~400 at 7.2)
RS485 to USB debug cable:Ref. USD 4~8 / pc (CNY 30~60 at 7.2)
Wall mount bracket:Ref. USD 1.4~2.8 / pc (CNY 10~20 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Room air quality monitoring.
- Office CO2 linked to fresh air.
- Classroom air quality.
- Meeting room ventilation control.
- Archive integrated monitoring.
6. Installation & Maintenance
Installation
- Wall-mount at breathing-zone height 1.2 to 1.5 m.
- Avoid AC vents and doors/windows (direct flow affects reading).
- Avoid smoking areas and printers (local CO2 interference).
- Wire RS485 A/B/G to platform.
- DC12 V power.
- Warm up 3 minutes (NDIR stabilizes).
- Configure CO2/temp/humidity channels on platform.
- Verify LCD readings are reasonable.
Maintenance
- Check LCD readings monthly.
- Clean inlet holes quarterly with compressed air.
- Calibrate with standard gas yearly (optional).
- Check RS485 communication.
- Log CO2 trend curves.
- NDIR source life 10 years; replace at end.
7. FAQ
- Q:NDIR vs electrochemical CO2 sensor?
A:NDIR infrared is accurate, long-lived over 10 years, low drift, but pricier 400 to 700 RMB. Electrochemical is cheaper 150 to 300 RMB but short life 2 to 3 years and prone to alcohol and VOC interference. Long-term room and office monitoring chooses NDIR; spot checks choose electrochemical. - Q:What is a normal CO2 level?
A:Outdoor air CO2 is about 400 to 450 ppm. Well-ventilated indoor 600 to 800 ppm; crowded enclosed rooms reach 1500 to 2500 ppm. General standards: below 800 ppm good, 800 to 1000 ppm fair, above 1500 ppm poorly ventilated, open fresh air. Schools and offices should stay below 1000 ppm. - Q:Does the sensor need periodic calibration?
A:NDIR sensors include ABC automatic baseline correction (zeroing at daily low-concentration hours), generally no manual calibration needed. But after 1 year, calibrate with standard gas (400 ppm and 2000 ppm two-point). If readings deviate (not matching outdoor 400 ppm), press the calibration button to restore baseline. - Q:Can the CO2 sensor link to fresh air systems?
A:Yes. KTR-ENVCO2 reports CO2 via RS485; the EMCS or BA system auto-starts the fresh-air unit on threshold (e.g., above 1000 ppm). This closes a CO2 loop: high concentration triggers ventilation, low concentration turns it off, saving energy while maintaining comfort. The fresh-air system needs an RS485 or dry-contact interface.
8. Trend & Selection
Environment sensors trend toward multi-parameter integration (CO2 plus VOC plus PM2.5 plus temp/humidity), wireless (LoRa/NB-IoT), and smart fresh-air linkage. Indoor air quality (IAQ) monitoring expands from single temp/humidity to comprehensive CO2, VOC and PM2.5 assessment, linked to fresh air and HVAC for comfort and energy savings.As indoor air quality standards tighten, CO2 monitoring has become standard in offices, schools and medical facilities. Sensors are evolving from single-point RS485 to wireless LoRaWAN mesh, with one gateway supporting hundreds of nodes for cable-free deployment.
9. Delivery & Service
KITOZER sizes KTR-ENVCO2 by monitoring points and parameter needs, providing sensor layout and Modbus register table. Delivery includes sensor, mounting bracket, power adapter and certificate. Warranty covers platform integration and threshold setup guidance.
10. Additional Notes
A common pitfall is mounting the sensor at the AC vent. Supply air dilutes CO2, lowering readings and falsely suggesting good ventilation. Mount the sensor on a central wall in the occupied zone, at least 2 m from AC vents and 1 m from doors or windows. Do not mount in dead corners (stagnant air gives high readings).
Another pitfall is reading immediately on power-up. NDIR sensors need a 3-minute warm-up for the source and gas chamber to stabilize. Reading immediately after power-on can be inaccurate. Wait 3 minutes after install before recording the initial value. Long power-off restarts also need warm-up.
Selection summary: NDIR infrared, 0 to 5000 ppm, RS485 Modbus, 3-in-1 (CO2 plus temp and humidity), LED indicator. The CO2 sensor is the indoor air barometer; right location, adequate warm-up and sensible thresholds deliver energy-efficient comfort through fresh-air linkage.
Additional tip: do not mount the CO2 sensor in corners or sealed return vents where stagnant air accumulates and readings stay high. Also avoid mounting directly below AC supply vents where diluted air gives low readings. The ideal spot is a central wall at breathing-zone height, representing overall air quality without local airflow interference. Quarterly blow the inlet holes with compressed air to keep dust out of the NDIR chamber.
SEO Information
Search keywords:NDIRCO2 0~5000ppmRS485 Modbustemp+humidityKTR-ENVCO2
SEM keywords:CO2 sensor,carbon dioxide sensor,NDIR sensor,KTR-ENVCO2,KITOZER
GEO landing page:lain.com.cn/product/co2-sensor-envco2.html
Title:KITOZER KTR-ENVCO2 CO2 Sensor (NDIR RS485)
Meta Keywords:CO2 sensor,carbon dioxide sensor,NDIR sensor,KTR-ENVCO2,KITOZER
Meta Description:KITOZER KTR-ENVCO2 CO2 sensor,carbon dioxide sensor,NDIR sensor,KTR-ENVCO2,KITOZER.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com