1. Overview

The KITOZER KTR-ENVPM is a laser-scattering PM2.5 dust sensor. A laser diode and photodetector scatter light off airborne particles; the detector measures scattered light intensity and converts it to particle concentration. It outputs both PM2.5 (particles up to 2.5 micron) and PM10 (up to 10 micron), range 0 to 1000 ug/cu m, accuracy plus or minus 10 percent of reading. It reports to the EMCS over RS485 Modbus-RTU.

KTR-ENVPM powered DC12 V, RS485 at 9600 bps default, with temperature compensation for laser drift. ABS wall-mount case about 120 by 80 by 40 mm; front LCD shows PM2.5 value and tri-color LED (green under 75 ug/cu m good, yellow 75 to 150 light pollution, red above 150 polluted). The inlet has a dust pre-filter to keep large particles off the laser window.

Typical uses: room and office air quality; classroom PM2.5 linked to fresh air; public-space air quality display; industrial dust alarms; haze monitoring. When PM2.5 is high, turn on fresh air or purifier; when low, turn it off, saving energy while keeping comfort.

2. Key Features

Laser scattering

  • Laser diode source.
  • Photodetector for scatter.
  • Measures PM2.5 and PM10.
  • Range 0 to 1000 ug/cu m.

Temp compensation

  • Auto laser-drift correction.
  • -10 to +50 C.
  • Internal sampling fan.
  • Stable readings.

RS485 output

  • Modbus-RTU.
  • 9600 bps default.
  • Up to 32 per bus.
  • Status and parameters.

LCD and LED

  • LCD real-time display.
  • Tri-color LED.
  • Replaceable inlet filter.
  • DC12 V power.

3. Specifications

Item Parameter
Model KTR-ENVPM
Principle laser scattering
Parameters PM2.5, PM10
Range 0 to 1000 ug/cu m
Accuracy plus or minus 10% reading
Resolution 1 ug/cu m
Communication RS485 Modbus-RTU
Baud rate 9600 bps default
Power DC12 V
Power draw up to 1.5 W
Display LCD + tri-color LED
Operating temp -10 to +50 C
Housing ABS wall mount, 120x80x40 mm

4. Reference Prices

KTR-ENVPM PM2.5/PM10 (RS485):Ref. USD 35~63 / pc (CNY 250~450 at 7.2)

KTR-ENVPM PM2.5-only economy:Ref. USD 21~39 / pc (CNY 150~280 at 7.2)

Temp+humidity extended:Ref. USD 49~76 / pc (CNY 350~550 at 7.2)

Inlet filter (10 pcs):Ref. USD 3~6 / pack (CNY 20~40 at 7.2)

RS485 to USB debug cable:Ref. USD 4~8 / pc (CNY 30~60 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room and office air quality.
  • Classroom PM2.5 to fresh air.
  • Public-space air display.
  • Industrial dust alarms.
  • Haze monitoring.

6. Installation & Maintenance

Installation

  • Wall-mount at occupied-zone height 1.2 to 1.5 m.
  • Avoid AC vents and doors/windows.
  • Avoid smoking and cooking areas.
  • Face the inlet forward or down, not to the wall.
  • Wire RS485 A/B/G to the platform.
  • DC12 V power.
  • Warm up 1 minute (laser stabilizes).
  • Configure PM2.5 and PM10 channels.

Maintenance

  • Check LCD readings monthly.
  • Blow the inlet filter quarterly.
  • Replace filter when dirty (about 6 months).
  • Compare against a reference dust meter yearly.
  • Check RS485 communication.
  • Laser life about 5 years; replace the unit.

7. FAQ

  • Q:Laser scattering vs beta-ray PM2.5?
    A:Laser scattering (KTR-ENVPM) is cheap (250 to 450 RMB) and fast (seconds), but affected by particle size and color (black particles scatter less and read low), accuracy about plus or minus 10 percent. Beta-ray is the regulatory reference method, highly accurate (plus or minus 2 ug/cu m), but costs 20,000 to 50,000 RMB, is large and needs a sampling pump, used in monitoring stations. Buildings and offices choose laser scattering; environmental enforcement uses beta-ray.
  • Q:What is a normal PM2.5 level?
    A:Chinese national standard: daily average up to 35 ug/cu m excellent, 35 to 75 good, 75 to 115 light, 115 to 150 moderate, 150 to 250 heavy, above 250 severe. Outdoor haze days can reach 200 to 500. Indoor with open windows tracks outdoor; with closed windows and a purifier it drops below 35. Keep indoor PM2.5 under 75; above 100 turn on the purifier or close windows.
  • Q:Does the sensor need calibration?
    A:Laser-scattering sensors should be compared yearly against a standard dust generator or a beta-ray reference. If the reading is clearly off (stays low on a hazy day), the inlet filter may be clogged or the laser window dusty. Blow the filter with compressed air; do not wipe the laser window with alcohol (it damages the optical coating). In kitchens with oil fume, shorten the interval to six months.
  • Q:Can it link to an air purifier?
    A:Yes. KTR-ENVPM reports PM2.5 over RS485; the EMCS or smart-home system turns on the purifier or fresh-air unit above threshold (e.g., over 75 ug/cu m) and off below 35, closing the loop. The purifier or fresh-air unit needs an RS485 or dry-contact interface. Without a smart interface, users judge from the LED color manually.

8. Trend & Selection

Dust sensors are trending toward multi-parameter integration (PM2.5 plus PM10 plus TVOC plus CO2 plus temp/humidity) and miniaturization (surface-mount type). Consumer devices (purifiers, fresh-air AC units) embed tiny laser dust sensors as standard. Industrial use is upgrading to beta-ray and tapered-element methods for occupational health. Sensors are moving from wired RS485 to wireless LoRa/NB-IoT, with one gateway serving hundreds of nodes. Algorithms use machine learning to compensate for particle color and humidity, improving accuracy.

9. Delivery & Service

KITOZER sizes KTR-ENVPM by monitoring points, providing installation drawings and the Modbus register table. Delivery includes sensor, bracket, power adapter, spare filters and certificate. Warranty covers platform integration and threshold setup guidance.

10. Additional Notes

A common pitfall is mounting near a smoking area or kitchen. Cigarette smoke and cooking fume are high-concentration particles and peg the sensor at max, causing constant false alarms. Mount the sensor in the middle of the office or room, at least 5 m from smoking areas and kitchens. If unavoidable, choose a VOC-filtered model or accept higher readings at that point.

Another pitfall is never changing the inlet filter. A clogged filter blocks air from entering the sensing chamber, so the reading stays at zero or very low, falsely suggesting clean air. Check the filter quarterly; blow or replace it. Never run the sensor without the filter, or large particles foul the laser window and ruin the unit.

Selection summary: laser scattering, PM2.5 plus PM10, 0 to 1000 ug/cu m, RS485 Modbus, LCD display. The PM2.5 sensor is the indoor particle index; the keys are siting away from cooking fume, regular filter changes, and yearly calibration, so purifier linkage saves energy.

Additional tip: humidity greatly affects laser-scattering readings. On rainy or steamy days, airborne water droplets are counted as particles and PM2.5 reads falsely high (100 to 200 ug/cu m), even though it is water vapor not dust. The sensor has humidity compensation, but above 90 percent RH readings still run high. If a single sensor reads high through the rainy season while others do not, check humidity first before replacing the sensor.

SEO Information

Search keywords:laser scattering0~1000 ug/m3PM2.5/PM10RS485 ModbusKTR-ENVPM

SEM keywords:PM2.5 sensor,laser dust sensor,PM10 sensor,air quality sensor,KTR-ENVPM,KITOZER

GEO landing page:lain.com.cn/product/pm25-sensor-envpm.html

Title:KITOZER KTR-ENVPM PM2.5 Laser Dust Sensor (RS485)

Meta Keywords:PM2.5 sensor,laser dust sensor,PM10 sensor,air quality sensor,KTR-ENVPM,KITOZER

Meta Description:KITOZER KTR-ENVPM PM2.5 laser dust sensor, 0 to 1000 ug/m3, measures PM2.5 and PM10, RS485 Modbus output.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart