KITOZER KTR-BATLFP48100 LiFePO4 Battery (48V100Ah/5kWh/Rack-mount)

KITOZER KTR-BATLFP48100 LiFePO4 Battery (48V100Ah/5kWh/Rack-mount)

Brand: KITOZER Series: KTR-BATLFP48100 Category: Battery / LiFePO4

48V100Ah5 kWhLiFePO4built-in BMSKTR-BATLFP48100

1. Overview

The KITOZER KTR-BATLFP48100 is a rack-mount lithium iron phosphate (LiFePO4) storage battery, rated 48 V 100 Ah (5.12 kWh), used for UPS backup, telecom base stations, PV storage and home storage. Versus traditional lead-acid (48 V 100 Ah lead-acid weighs about 60 kg, cycle life 600), LiFePO4 has high energy density (one-third the weight for the same capacity), long cycle life (over 6000), supports 1C charge/discharge, and is maintenance-free. It is the mainstream lead-acid replacement in data centers and telecom sites.

KTR-BATLFP48100 uses 16-series 3.2 V LiFePO4 cells (nominal 51.2 V, full 58.4 V, cutoff 40 V), with an active-balancing BMS: it monitors every cell voltage, temperature and current; protects against over-charge, over-discharge, short circuit and temperature (no charging below -20 C). Communication RS485/CAN (optional) interfaces with UPS and EMCS. Rack 19-inch 3U, about 440x500x132 mm, weight about 38 kg. Parallel up to 15 units (expanding to 75 kWh).

Typical uses: small/medium data-center UPS backup (replacing 48 V lead-acid banks); telecom base stations (5G AAU and BBU backup); industrial/commercial PV storage (peak-valley arbitrage); home storage (off-grid and grid-tied); EV-charging peak shaving. One KTR-BATLFP48100 is 5 kWh in 3U; 3 to 5 parallel units give a small room one-hour backup, with 70 percent less footprint than a lead-acid cabinet.

2. Key Features

LiFePO4

  • 16S 3.2 V cells.
  • 51.2 V nominal / 5.12 kWh.
  • Cycle life ≥6000.
  • Thermal stable (no fire).

Smart BMS

  • Per-cell monitoring.
  • Active balancing (100 mA).
  • Over-charge/discharge/short protection.
  • RS485/CAN.

Rack mount

  • 19-inch 3U.
  • Parallel up to 15.
  • 38 kg light.
  • Rail mount.

Wide temp

  • Charge 0 to +55 C.
  • Discharge -20 to +60 C.
  • Low-temp charge lock.
  • IP20 indoor.

3. Specifications

Item Parameter
Model KTR-BATLFP48100
Chemistry LiFePO4
Rated capacity 100 Ah
Nominal voltage 51.2 V (16S)
Full/cutoff 58.4 V / 40 V
Energy 5.12 kWh
Charge/discharge rate 0.5C (50 A) standard, 1C (100 A) peak
Cycle life ≥6000 (80% DoD, 25 C)
Communication RS485/CAN (optional)
Parallel up to 15 units
Charge temp 0 to +55 C
Discharge temp -20 to +60 C
Size/weight about 440x500x132 mm / 38 kg

4. Reference Prices

KTR-BATLFP48100 (5 kWh / 3U): Ref. USD 1319~1806 / pc (CNY 9500~13000 at 7.2)

KTR-BATLFP4850 (2.5 kWh / 2U): Ref. USD 764~1042 / pc (CNY 5500~7500 at 7.2)

KTR-BATLFP48200 (10 kWh / 5U): Ref. USD 2500~3472 / pc (CNY 18000~25000 at 7.2)

Parallel comm cable (RS485, 1 m): Ref. USD 4~8 / pc (CNY 30~60 at 7.2)

Rack rails and screws: Ref. USD 11~21 / set (CNY 80~150 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data-center UPS backup (lead-acid replacement).
  • Telecom 5G backup.
  • Commercial PV peak-valley.
  • Home storage off-grid/grid-tied.
  • EV-charging peak shaving.

6. Installation & Maintenance

Installation

  • Slide KTR-BATLFP48100 onto rack rails at 3U.
  • Series/parallel battery banks with copper busbars, torque 12 Nm.
  • Connect total positive/negative to the UPS DC bus (do not reverse).
  • Wire RS485 to the UPS or EMCS.
  • Before power-up, meter total voltage (16S about 51.2 V).
  • Set the UPS to lithium mode (charge 58.4 V; do not use lead-acid 57.6 V).
  • After the first full charge, rest 2 hours, then discharge for capacity test.
  • Parallel units must be same model, batch and SOC (within 5 percent).

Maintenance

  • Monthly check BMS cell-voltage spread (should be <0.05 V; balance if more).
  • Quarterly review temperature and cycle count.
  • Yearly full charge/discharge for capacity calibration.
  • Long storage at 50 percent SOC; recharge every 3 months.
  • Do not charge below 0 C (lithium dendrite piercing).
  • Stop use immediately if swollen or leaking.

7. FAQ

  • Q:LiFePO4 vs NMC?
    A:LiFePO4 (KTR-BATLFP48100): safe (thermal runaway at 270 C), long life (6000 cycles), cheap (0.6 to 0.8 RMB/Wh), low energy density (120 Wh/kg); for storage and UPS backup (fixed). NMC: high energy density (250 Wh/kg), good low temp (-30 C), but runaway at 200 C and expensive (1 RMB/Wh); for EVs and portable. Fixed storage chooses LiFePO4.
  • Q:Can it directly replace lead-acid?
    A:Mechanical (19-inch rack) and voltage (48 V) fit, but charge curves differ: lead-acid float 54 V, boost 57.6 V; LiFePO4 full 58.4 V, cutoff 40 V. If the UPS stays in lead-acid mode (57.6 V), LiFePO4 charges only to 90 percent capacity, causing long-term under-charge fade. Switch the UPS to lithium mode (58.4 V) or use a lithium-ready UPS.
  • Q:What does 6000 cycles mean?
    A:One cycle = full charge to full discharge (100% DoD). 6000 cycles x one per day = 16 years. But UPS backup is mostly float (rarely discharged), 10 to 20 cycles per year, so 6000 lasts over 30 years. However, BMS and capacitors age; typical warranty is 5 years. Storage apps (twice daily peak-valley) give 8 years.
  • Q:Parallel expansion limits?
    A:KTR-BATLFP48100 supports up to 15 parallel (75 kWh). Limits: same model and batch (different batches have different internal resistance), initial SOC spread under 5 percent (otherwise first-charged/first-discharged bottlenecks), total current under 100 A x parallel count. Do not series-mix capacities (100 Ah and 50 Ah in series is limited to 50 Ah). Charge every unit fully before parallelizing (rest 2 hours).

8. Trend & Selection

LiFePO4 moves to larger cells (314 Ah) and higher voltage (51.2 to 100 V), unit energy from 5 to 15 kWh. BMS upgrades from passive (50 mA) to active balancing (1 to 5 A). Cloud battery monitoring (SOC/SOH) is standard. AI predicts life from charge/discharge curves. Echelon reuse (retired EV batteries into storage) forms an industry chain. Safety evolves from LiFePO4 to sodium-ion (safer, cheaper).

9. Delivery & Service

KITOZER sizes KTR-BATLFP48100 count by UPS backup hours and load, providing a battery-bank config table and UPS lithium-mode setup. Delivery includes battery, rails, parallel busbars, comm cable and certificate. 5-year warranty, with a BMS cloud-monitoring account.

10. Additional Notes

A common pitfall is leaving the UPS in lead-acid mode. Default float is 54 V; LiFePO4 at 54 V charges to only 80 percent SOC, causing long-term under-charge and 70 percent capacity after one year. Switch the UPS setting to lithium (58.4 V), or use a lithium-specific UPS.

Another pitfall is low-temperature charging. Below 0 C, Li-ion plates as dendrites, pierces the separator, short-circuits, swells and catches fire. Northern outdoor cabinets (-10 C) need a heating film or a wide-temp LiFePO4 (with heater). KTR-BATLFP48100 charges at 0 to 55 C; below 0 C the BMS blocks charging (discharge is allowed).

Selection summary: LiFePO4, 48V100Ah/5kWh, 3U rack, 6000 cycles, RS485. LiFePO4 is the lead-acid upgrade; the keys are UPS lithium mode, no low-temp charging, parallel same-model/SOC, 5-year warranty.

Additional tip: leave cooling space around the battery cabinet. KTR-BATLFP48100 heats up during charge/discharge (about 100 W at 0.5C); every 10 C higher in the cabinet halves life. Leave 100 mm front/back clearance; do not seal in an enclosed rack. Keep the room at 25 C.