1. Overview
The KITOZER KTR-SPD-RJ45 is a network signal surge protective device (also called a network arrester or Ethernet surge protector) installed in series between an outdoor network cable and the camera/switch port, protecting equipment from lightning-induced surges. A lightning rod only stops direct strikes; when lightning hits nearby, electromagnetic induction surges thousands of volts onto network and power cables, and that voltage flows into the equipment, killing the PHY chip. KTR-SPD-RJ45 uses a gas discharge tube (GDT) and TVS diode: during normal communication the cable passes straight through; on a surge the unit clamps voltage to a safe level (about 8 to 10 V) and diverts surge energy to ground.
KTR-SPD-RJ45 has two RJ45 ports (IN from the cable, OUT to the device), a built-in 100 M Ethernet transformer (no packet loss, no speed loss), 5 kA surge rating (8/20 microsecond waveform), and sub-nanosecond response. It clips onto a 35 mm DIN rail or can be wall-mounted. The ground lug connects to the rack ground bar (grounding resistance <=4 ohms).
Typical uses: outdoor camera ports (the camera is outside, the cable enters the room; a surge on the cable would kill both camera and switch, so add KTR-SPD-RJ45 on the indoor end); switch room incoming lines; wireless AP ports; door controller ports. Any outdoor-cable-to-indoor-equipment link should have a signal SPD on the indoor end. Power SPD (KTR-SPD-2P-40kA from the 845 line) protects the supply; signal SPD (KTR-SPD-RJ45) protects the network cable; together they form complete protection.
2. Key Features
RJ45 in-line
- IN / OUT RJ45 ports.
- 100 M transformer, no packet loss.
- Plug and play, no setup.
- PoE version available.
5 kA surge
- 5 kA (8/20 microsecond).
- Response <1 ns.
- Clamp 8 to 10 V.
- GDT + TVS two-stage.
DIN rail
- 35 mm DIN rail clip.
- Wall-mount option.
- Compact 90x60x25 mm.
- M4 ground lug.
Status LED
- Green = normal.
- Red = failed, replace.
- Built-in fault indicator.
- No opening for inspection.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-SPD-RJ45 |
| Type | Network signal SPD (RJ45) |
| Ports | RJ45 IN / OUT |
| Network | 10/100 M Ethernet (use KTR-SPD-RJ45-G for GigE) |
| Max rate | 100 Mbps |
| Surge (8/20 us) | 5 kA |
| Response | <1 ns |
| Clamp voltage | 8 to 10 V |
| Insertion loss | <=0.5 dB |
| Components | GDT + TVS |
| Ground | M4 screw, >=2.5 mm2 wire |
| Mounting | DIN rail / wall |
| Temp | -40 to +70 C |
| Housing | Flame-retardant plastic 90x60x25 mm |
| Indicator | LED (green normal / red fail) |
4. Reference Prices
KTR-SPD-RJ45 (100 M, 5 kA): Ref. USD 8~15 / pc (CNY 60~110 at 7.2)
KTR-SPD-RJ45-G GigE (1000 M): Ref. USD 13~21 / pc (CNY 90~150 at 7.2)
KTR-SPD-RJ45-POE PoE version: Ref. USD 14~25 / pc (CNY 100~180 at 7.2)
KTR-SPD-2P-40kA power SPD (2P, 40kA): Ref. USD 25~39 / pc (CNY 180~280 at 7.2)
Ground wire (2.5 mm2, per meter): Ref. USD 0.7~1.4 / m (CNY 5~10 at 7.2)
DIN rail (35 mm, 1 m): Ref. USD 2~3.5 / pc (CNY 15~25 at 7.2)
Reference only; 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Outdoor camera cable runs.
- Switch room incoming lines.
- Wireless AP ports.
- Door controller ports.
- IP intercom ports.
- Outdoor base station drops.
6. Installation & Maintenance
Installation
- Clip the SPD on the DIN rail near the protected equipment.
- Run the outdoor cable to IN.
- Run the indoor cable to OUT.
- Bond the ground lug to the rack ground bar with 2.5 mm2 wire.
- Keep the ground wire short (<=0.5 m); do not coil it (coiling adds inductance).
- Power on; green LED should light.
- Test continuity with a cable tester; all 8 wires should pass.
- Parallel multiple SPDs to a common ground.
Maintenance
- Quarterly: check LED (green ok; red replace).
- Before storm season: inspect ground wire tightness.
- Yearly: measure ground resistance (<=4 ohms).
- After a lightning event: check LED immediately; replace if red.
- SPDs are consumables; after a surge event, replace even if green (components age).
- Do not stack gear on the SPD.
7. FAQ
- Q:Do I need both power and network SPD?
A:Yes. Surges travel on both power and network cables. A power-only SPD leaves the network cable path open; the surge kills the PHY chip. Complete protection: main incoming power has a stage-1 power SPD (80 kA), equipment has stage-2 (40 kA), and every outdoor network drop has a network SPD (KTR-SPD-RJ45). All three are needed. - Q:Which SPD for PoE cameras?
A:The standard KTR-SPD-RJ45 (60 to 110 RMB) blocks PoE power. PoE cameras require KTR-SPD-RJ45-POE (100 to 180 RMB), which passes both data and PoE. Non-PoE gear (ordinary switches) can use the standard version. - Q:Which SPD for Gigabit?
A:The standard KTR-SPD-RJ45 (100 M) passes only 4 wires (1/2/3/6); GigE needs all 8. Use KTR-SPD-RJ45-G (90 to 150 RMB) with a GigE transformer. Putting a 100 M SPD on a GigE link drops the speed to 100 M. - Q:Does a poor ground make the SPD useless?
A:Yes. The SPD diverts surge energy to ground; if ground resistance exceeds 10 ohms, energy cannot escape, clamp voltage spikes, and the equipment still dies. Grounding must be <=4 ohms, with short thick wire (>=2.5 mm2). A bad ground means no protection at all.
8. Trend & Selection
Signal SPDs move from single RJ45 to multi-port units (8-port in one box) for rack patch panels. Speeds move from 100 M to GigE / 2.5G / 10G. SPDs add remote fault reporting over the network. PoE drives PoE-rated SPDs to become mainstream. Power and signal SPDs merge into combined units.
9. Delivery & Service
KITOZER sizes KTR-SPD-RJ45 by network speed and PoE requirement, supplying grounding guidance. Delivery includes SPD, DIN clip, manual and certificate. Warranty covers installation guidance and failed-unit replacement.
10. Additional Notes
A common pitfall is reversing IN and OUT. IN takes the outdoor cable; OUT goes to the indoor device. Reversed, the surge hits the device before the SPD, rendering the unit useless. Follow the labels on the housing.
Another pitfall is coiled ground wires. Installers coil 3 meters of ground wire to the bar; the added inductance slows surge discharge and raises clamp voltage. Keep the ground wire short and straight, <=0.5 m, >=2.5 mm2.
Selection summary: RJ45; 100 M; 5 kA; IN outside / OUT device; ground <=4 ohms. Signal SPDs are the guardian of outdoor gear; the keys are correct orientation, short thick ground, and LED checks after storms.
Additional tip: stage the protection. Main incoming has stage 1 (80 kA) coarse protection; equipment has stage 2 (40 kA / 5 kA) fine protection. A single 5 kA at the equipment will sacrifice itself during a big strike, but may not save the gear. Stage 1 absorbs most energy; stage 5 does the final clamp.