Table of Contents
ToggleKITOZER-CDC-40A: 40ft Air-cooled Modular Container Data Center (80 kW IT Load) — Factory Price
A single 40ft high-cube container, factory pre-integrated and pre-commissioned with power distribution, in-row cooling, cold-aisle containment, fire suppression, BMS and structured cabling. On site, just connect mains power and a fiber link — it carries 10×42U racks for a total of 80 kW IT load. Air-cooled direct-expansion design: no cooling water, no secondary water loop — built for edge campuses, mining / oilfield sites, temporary rooms and rapid capacity expansion.
2–4 weeks from delivery to live load
Container, base, insulation, sealing, racks, busbar, PDUs, outdoor condensers, FM200 and BMS — all factory-installed. No on-site room build, no overhead tray rework, no long cable pulls.

01 · Why Air-Cooled, Not Liquid
At the 80 kW IT tier, an air-cooled DX room is lighter than a liquid-cooled shelter in three ways: first, the site only needs a power feed — no cooling tower, CDU, secondary water loop or make-up water system; second, in-row CRAH blows cold air straight to the rack intake, and with cold-aisle containment PUE lands at 1.4–1.5; third, the whole container can be crane-shifted to the next site without re-plumbing water.
02 · Enclosure & Envelope: IP55 Drop-in Outdoor
The container is Q235 weathering steel, external 12192×2438×2896 mm (40HQ high cube), C5-M corrosion class, 50 mm Class-A rock-wool on walls and roof, 20 mm XPS underfloor plus 600×600 mm steel raised-access floor at 300 mm height (≥1000 kg/m²). EPDM gaskets on doors, bottom waterproof curb and rain-flap seams bring the whole unit to IP55. Two 600×800 mm tempered-glass emergency escape windows, one on each side.

03 · Power: 100 kVA Modular UPS + 32-cell Battery Backup
- Mains feeds the 160 A input distribution cabinet with Class-II surge protection and a smart power meter;
- 100 kVA / 90 kW three-phase modular UPS, N+1 power-module redundancy, ≥96% efficiency, parallel-expandable;
- 32×12 V 100 Ah VRLA batteries in series give ≥15 minutes at 80 kW, housed in a double-deck battery cabinet;
- The 125 A UPS output cabinet splits to 10 circuits of 3P 32 A to the racks, each branch with voltage/current sensing;
- 32 A overhead plug-in busbar feeds A/B dual-path smart PDUs (12×C13 + 4×C19), two per rack.
04 · Air Cooling: 2×45 kW In-row CRAH, N+1
Two 45 kW air-cooled DX in-row precision air conditioners (R410A, EC variable-speed fans, sensible ratio ≥0.9) run N+1 — 90 kW total cooling against 80 kW IT plus ancillary heat. Two matching outdoor condensers sit on the roof and support low-temperature start-up. Cold-aisle containment uses transparent tempered-glass doors and a roof hatch that opens on fire-alarm signal, combined with rack blanking panels and bottom gaskets to suppress hot/cold air mixing.

05 · Fire, BMS & Security
Two 70 L cabinet FM200 units (42 kg agent each) deliver total-flooding suppression. An addressable fire alarm panel supervises 8 smoke detectors, 4 heat detectors, 2 manual call points, 2 sounder/strobes, 2 gas-release indicators and 1 mechanical pressure-relief vent. The 10-inch touch BMS controller (KITOZER-ENV-DH10) unifies branch power, temperature/humidity, leak, access control and CCTV, pushing alarms via sounder / SMS / email / Web / APP.

06 · Full Bill of Materials — KITOZER Quotation (USD)
49 line items in total. KITOZER factory quote, USD (ex-works; shipping and installation excluded; final per contract).
| System | Item | Model | Spec (brief) | Qty | Unit | Unit US$ | Amount US$ |
|---|---|---|---|---|---|---|---|
| 01 · Enclosure | 40ft High-Cube Container Body | KITOZER-CDC-40A | 外尺寸12192×2438×2896mm;Q235耐候钢,防腐C5-M;50mm岩棉保温防火A级;双开防盗密封门,IP55 | 1 | unit | 35,417 | 35,417 |
| 01 · Enclosure | Base Steel Plinth | KITOZER-CDC-DJ125 | 12500×2500mm镀锌槽钢焊接,调平支脚,承重≥20吨 | 1 | set | 5,208 | 5,208 |
| 01 · Enclosure | Booth Raised Access Floor | KITOZER-FJD600 | 600×600mm,高300mm,承重≥1000kg/㎡,符合GB/T 36340 | 1 | set | 7,500 | 7,500 |
| 01 · Enclosure | Thermal Insulation Package | KITOZER-BW-50 | 墙/顶50mm岩棉,地面20mm挤塑板,导热≤0.040W/(m·K) | 1 | set | 3,542 | 3,542 |
| 01 · Enclosure | IP55 Weather Sealing | KITOZER-FS-IP55 | 门框三元乙丙胶条+底部防水围堰+门缝防雨,整体IP55 | 1 | set | 2,833 | 2,833 |
| 01 · Enclosure | Emergency Escape Window | KITOZER-TC6080 | 600×800mm钢化玻璃,带安全锤,消防逃生规范 | 2 | pc | 500 | 1,000 |
| 02 · Power | Modular UPS System | KITOZER-UPS-100K | 三进三出100kVA/90kW;N+1功率模块冗余;效率≥96%;直流母线384V | 1 | unit | 24,167 | 24,167 |
| 02 · Power | VRLA Battery (12V 100Ah) | KITOZER-LFP-12100 | 12V 100Ah阀控密封;32节串联成组;80kW后备≥15分钟 | 32 | cell | 396 | 12,672 |
| 02 · Power | Battery Cabinet (32-slot) | KITOZER-DCG32 | 容纳32节12V100Ah电池,双列四层,含连接缆 | 1 | unit | 1,000 | 1,000 |
| 02 · Power | Mains Input Distribution Cabinet | KITOZER-PDG160 | 进线160A 3P塑壳;UPS/空调/辅助/消防分路;II级浪涌+智能电量仪 | 1 | unit | 6,583 | 6,583 |
| 02 · Power | UPS Output Distribution Cabinet | KITOZER-PDG125 | 进线125A 3P;10路3P 32A机柜支路;每支路电压电流监测 | 1 | unit | 5,208 | 5,208 |
| 02 · Power | Overhead Busbar Duct | KITOZER-MX32 | 3P+N+PE,32A;含始端箱、终端箱、插接单元 | 10 | pc | 750 | 7,500 |
| 02 · Power | Rack-mount Smart PDU | KITOZER-PDU32 | 32A输入,12×C13+4×C19;电流/电压/功率显示,支持级联 | 20 | unit | 500 | 10,000 |
| 02 · Power | Earthing Busbar | KITOZER-JD40 | 40×4mm紫铜排通长布置,配接地端子与连接缆 | 1 | set | 3,542 | 3,542 |
| 02 · Power | Power Cables & Auxiliaries | KITOZER-CAB-BULK | YJV电力电缆+控制电缆+镀锌桥架+线鼻+扎带+标识全系统辅材 | 1 | lot | 10,417 | 10,417 |
| 03 · Cooling | In-row Precision CRAH (Indoor) | KITOZER-PAC-45 | 45kW/台风冷直膨;显热比≥0.9;EC无极风机;R410A;600×1200×2000mm | 2 | unit | 31,250 | 62,500 |
| 03 · Cooling | Air-cooled Outdoor Condenser | KITOZER-PAC-45OT | 配45kW室内机;调速轴流风机;防腐外壳;支持低温启动 | 2 | unit | 7,500 | 15,000 |
| 03 · Cooling | Refrigerant Piping Set | KITOZER-REF-PIPE | 紫铜管+橡塑保温;分歧管、管卡、密封件按路径配置 | 2 | set | 2,292 | 4,584 |
| 03 · Cooling | Cold Aisle Containment | KITOZER-LTD | 机柜冷侧封闭;钢化玻璃通道门;顶部天窗消防联动自动开启 | 1 | set | 12,417 | 12,417 |
| 03 · Cooling | Airflow Optimization Kit | KITOZER-QLY | 机柜盲板+导流密封条+底部密封件,降低PUE | 1 | set | 2,708 | 2,708 |
| 04 · Racks | Server Rack (42U) | KITOZER-NET-42U | 42U标准;600×1200×2000mm;前后网孔门通风率≥70%;承重≥1500kg | 10 | unit | 1,583 | 15,830 |
| 04 · Racks | Rack Cable Management Kit | KITOZER-LX10 | 每柜竖理线架2+1U水平理线器4+层板2+扎带标签 | 10 | set | 271 | 2,710 |
| 05 · Fire Suppression | Cabinet FM200 Suppression Unit | KITOZER-FIRE-70L | 70L容积,充装42kg七氟丙烷;2.5MPa;带压力表 | 2 | unit | 3,417 | 6,834 |
| 05 · Fire Suppression | Fire Alarm Control Panel | KITOZER-FIRE-FAC | 联动型;烟感/温感/手报/声光接入;联动灭火与切非 | 1 | unit | 2,708 | 2,708 |
| 05 · Fire Suppression | Photoelectric Smoke Detector | KITOZER-FIRE-SD | 编码型;灵敏度符合GB 4715 | 8 | pc | 117 | 936 |
| 05 · Fire Suppression | Rate-of-Rise Heat Detector | KITOZER-FIRE-HD | 编码型;符合GB 4716 | 4 | pc | 133 | 532 |
| 05 · Fire Suppression | Manual Call Point | KITOZER-FIRE-MCP | 编码型;带电话插孔;门口易操作位置 | 2 | pc | 75 | 150 |
| 05 · Fire Suppression | Sounder & Visual Alarm | KITOZER-FIRE-SA | 编码型;火警声+闪光 | 2 | pc | 108 | 216 |
| 05 · Fire Suppression | Gas Release Indicator | KITOZER-FIRE-IND | 门外侧;灭火释放时点亮警示 | 2 | pc | 62 | 124 |
| 05 · Fire Suppression | Mechanical Pressure Relief Vent | KITOZER-FIRE-REL | 有效面积0.12㎡;墙体上部;超压自动泄压 | 1 | pc | 750 | 750 |
| 06 · BMS | BMS Controller (10″ Touch) | KITOZER-ENV-DH10 | 嵌入式工控机+10寸触控;市电/UPS/电池/空调/温湿度/门禁/消防/漏水全接入 | 1 | unit | 3,250 | 3,250 |
| 06 · BMS | Branch Power Meter Module | KITOZER-ENV-DL10 | 单路电压/电流/功率/电能;配电柜输出支路安装 | 10 | pc | 158 | 1,580 |
| 06 · BMS | Temperature & Humidity Sensor | KITOZER-ENV-TH6 | ±0.5℃,±3%RH;RS485 | 6 | pc | 117 | 702 |
| 06 · BMS | Point-identification Leak Detection | KITOZER-ENV-LS01 | 10m检测绳+控制器;定位精度±1m | 1 | set | 1,167 | 1,167 |
| 06 · BMS | Access Control System | KITOZER-ENV-AC01 | 双门控制器;指纹+密码+刷卡;2读卡器+2出门按钮 | 1 | set | 1,875 | 1,875 |
| 06 · BMS | CCTV Kit (4-ch NVR) | KITOZER-ENV-CCTV01 | 4路200万像素红外网络摄像机;4路NVR+1T硬盘 | 1 | set | 1,583 | 1,583 |
| 06 · BMS | Remote Alarm Module | KITOZER-ENV-AL01 | 声光/短信/邮件告警;Web/APP远程查看 | 1 | set | 1,458 | 1,458 |
| 06 · BMS | Surveillance Switch (8-port) | KITOZER-ENV-SW08 | 8口千兆非网管以太网交换机 | 1 | unit | 158 | 158 |
| 07 · Cabling | Cat6 24-port UTP Patch Panel | KITOZER-CAT6-PP24 | CAT6 UTP;镀金触点;1U机架式 | 20 | pc | 158 | 3,160 |
| 07 · Cabling | Cat6 UTP Patch Cord (2m) | KITOZER-CAT6-PC2M | 2米;CAT6 UTP;福禄克测试 | 200 | pc | 8 | 1,600 |
| 07 · Cabling | 12-port LC SMF Patch Panel | KITOZER-LC-PP12 | 9/125μm单模;含耦合器尾纤;1U | 10 | pc | 133 | 1,330 |
| 07 · Cabling | LC-LC SMF Patch Cord (3m) | KITOZER-LC-LC3M | 3米;9/125μm单模;低插损 | 50 | pc | 15 | 750 |
| 07 · Cabling | 1U Horizontal Cable Manager | KITOZER-LXJ1U | 金属;19英寸标准 | 20 | pc | 27 | 540 |
| 07 · Cabling | Overhead Cable Tray | KITOZER-QJ01 | 镀锌槽式;强弱电分离;含支架连接件 | 1 | set | 3,542 | 3,542 |
| 08 · Lighting | LED Panel Light (40W) | KITOZER-LED40 | 600×600mm;40W白光;照度≥300lx | 6 | lamp | 75 | 450 |
| 08 · Lighting | Emergency Light | KITOZER-YJ02 | 自带锂电池;断电自亮;持续≥90分钟 | 2 | lamp | 117 | 234 |
| 08 · Lighting | Maintenance Power Outlet | KITOZER-CZ10 | 10A五孔;带保护门;箱体两侧分布 | 8 | pc | 35 | 280 |
| 08 · Lighting | Weather Louver | KITOZER-BY04 | 防虫网+防尘棉;箱体前后端 | 4 | pc | 188 | 752 |
| 08 · Lighting | Signage Kit | KITOZER-BS01 | 设备标识+安全警示+流向标识+机房管理制度牌 | 1 | set | 1,042 | 1,042 |
| Total | KITOZER Quotation Total (49 items) | — | — | — | — | — | 290,041 |
07 · Delivery & Service
- Factory pre-commissioning includes power-on, comms, fire-linkage and full-load thermal tests, with reports shipped with the container;
- Site scope: one 380 V 3P5W mains feed (≥200 kVA), one fiber / Ethernet drop, one hardened level pad (≥13×3 m);
- Standard lead time: 30–45 days ex-works after PO and payment; on-site to live load within 3 days;
- Warranty: 12 months whole unit, 24 months on batteries; 24/7 remote alarm, on-site within 48 h in major Chinese cities.
Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140
Web: lain.com.cn | gdlain.com
Add: Zhongrun Industrial Park Chaotian Zone, No.5 Huashan Road, Shilou, Panyu, Guangzhou, China