KITOZER Wall-Mounted Precision Air Conditioner 5 kW Constant T&H, Server Room & Outdoor Cabinet Price

KITOZER Wall-Mounted Precision Air Conditioner KITOZER-PAC-WALL-5kW: Constant T&H for Server Rooms, Outdoor Cabinets & Base Stations

Wall-mounted, zero floor space; small capacity 5–12 kW range; DC inverter, sensible ratio ≥0.9; temperature ±1°C, humidity ±5%RH.

Wall-Mounted5-12 kWConstant T&H
Sensible ≥0.9DC Inverter220V Single-PhaseSmall Room / Outdoor Cabinet / Base Station

1. Overview

The KITOZER-PAC-WALL series is a wall-mounted precision air conditioner developed by KITOZER for small server rooms, outdoor telecom cabinets, communication base stations and embedded rack rooms. The indoor unit mounts directly on the wall, saving the valuable floor space of a small room. It is well suited to a 4–5 m² room with one standard rack, edge sites, and constant-temperature/humidity needs inside outdoor cabinets. The series covers 5–12 kW, with the 5 kW (2 hp) model as the typical configuration.

Unlike a comfort room air conditioner, the KITOZER precision unit is tuned for sensible heat removal: a sensible ratio ≥0.9 avoids over-dehumidification and condensation; temperature control is ±1°C (adjustable 18–28°C). Optional humidification and electric-heating modules deliver ±5%RH constant temperature and humidity. The indoor unit integrates an evaporator, DC inverter fan, electronic expansion valve and G4 pre-filter; the outdoor unit uses an inverter compressor pre-charged with R410A.

2. Why a Wall-Mounted Precision AC

Zero Floor Space

The indoor unit hangs on the wall, leaving the floor free. A tidy layout even in a 4–5 m² room, with clear access in front of the rack.

Sensible-Heat Priority

Sensible ratio ≥0.9; 1500 m³/h airflow matches the “capacity × 250–300” room-airflow rule, removing equipment sensible heat fast without over-dehumidifying.

Wall-Mounted Control

KITOZER-ENV-DH10 wired LCD thermostat for mode, temp/humidity setpoints, fault codes and timer, all operated on the wall.

220V Single-Phase

Runs on ordinary room power; no three-phase supply needed, so legacy sites and outdoor cabinets can be retrofitted directly.

Constant T & H

Optional electrode humidifier (1 kg/h) and PTC heater (2 kW); humidity adjustable 40–60% RH at ±5%RH.

Unattended Ready

Optional power-fail auto-restart and RS485/SNMP environment module restore operation on power return and link to the room EMS.

3. Key Technical Data

Rated Cooling Capacity 5.0 kW (2 hp) at 24°C/50% RH; series range 5–12 kW
Sensible Capacity / SHR ≥4.5 kW / ≥0.9
Airflow 1500 m³/h
Power Supply 220V / 50Hz single-phase
Temp Accuracy / Range ±1°C, adjustable 18–28°C
Humidity Accuracy / Range ±5%RH (constant T&H version), adjustable 40–60% RH
Major Components DC inverter fan, electronic expansion valve, G4 pre-filter, inverter compressor, R410A refrigerant
Control KITOZER-ENV-DH10 wired LCD thermostat + NTC return-air sensor
Mounting Indoor on wall (4# angle-steel bracket, ≥80 kg); outdoor on wall or floor (5# angle-steel bracket, ≥100 kg)

4. KITOZER Quotation (5 kW Typical Configuration)

Standard KITOZER configuration quotation, including main units, refrigerant piping, electrical & control, air system and installation accessories — 28 items in total. Final brand, model and quantities are subject to the confirmed contract.

No. Model Item Specification Qty Unit Unit Price (USD) Amount (USD)
1. Main Units
1 KITOZER-PAC-WALL-5kW Wall-Mounted Precision AC Indoor Unit Cooling capacity 5 kW (2 hp); airflow 1500 m³/h; sensible ratio >=0.9; 220V/50Hz single-phase; wall-mounted; built-in evaporator, DC inverter fan, electronic expansion valve, G4 pre-filter; temperature control +/-1C (adjustable 18-28C) 1 unit $5,208 $5,208
2 KITOZER-PAC-ODU Air-Cooled Outdoor Unit Matched to the 5 kW indoor unit; inverter compressor; factory pre-charged with R410A; condenser, axial fan, high/low-pressure and discharge-temperature protection 1 unit $1,750 $1,750
3 KITOZER-ENV-DH10 Wired LCD Thermostat / Environment Controller Wired LCD thermostat for cooling/dehumidifying/fan mode, temp & humidity setpoints, fault code display, timer; wall-mounted inside the room entrance 1 pc $139 $139
4 KITOZER-ENV-NTC01 Room Temperature Sensor NTC thermistor, accuracy +/-0.5C, mounted on the indoor return-air side 1 pc $42 $42
2. Refrigerant Piping
5 KITOZER-PAC-PIPE-G12 Gas Refrigerant Pipe φ12.7 mm copper tube, de-oiled & degreased; default 10 m 10 m $14 $140
6 KITOZER-PAC-PIPE-L06 Liquid Refrigerant Pipe φ6.35 mm copper tube, de-oiled & degreased; default 10 m 10 m $14 $140
7 KITOZER-PAC-INS-T15 Refrigerant Pipe Insulation B1 flame-retardant elastomeric insulation, 15 mm thick, matched to pipe OD 20 m $0 $0
8 KITOZER-PAC-FLARE Copper Flare Joints Matched to gas/liquid pipe sizes; includes nuts and caps; one set indoor + one outdoor 2 set $14 $28
9 KITOZER-PAC-CLAMP Refrigerant Pipe Clamps Galvanized clamps matched to pipe OD; spacing about 1.2 m 18 pc $0 $0
10 KITOZER-PAC-DRAIN20 Condensate Drain Pipe φ20 mm PVC-U pipe, routed to the nearest drain 10 m $0 $0
11 KITOZER-PAC-DRAININS Drain-Pipe Insulation 10 mm elastomeric insulation to prevent surface condensation 10 m $0 $0
12 KITOZER-REF-R410A R410A Refrigerant Factory charge; pre-filled in outdoor unit; topped up if line set is longer than standard 1 batch $111 $111
3. Electrical & Control
13 KITOZER-PAC-CABLE-P Dedicated Power Cable ZR-BVV 3×2.5mm2 copper flame-retardant cable; from distribution box to outdoor unit then on to indoor unit 15 m $0 $0
14 KITOZER-PAC-CABLE-S Communication Cable 2×1.0mm2 shielded control cable for bidirectional indoor-outdoor communication 15 m $0 $0
15 KITOZER-PAC-MCB20 Leakage Circuit Breaker 2P 20A, 30 mA trip current; dedicated circuit in the room distribution box 1 pc $14 $14
16 KITOZER-PAC-CONDUIT PVC Conduit φ20 mm flame-retardant conduit; recessed or surface-mounted on the wall 15 m $0 $0
17 KITOZER-PAC-PE Grounding Wire 1×2.5mm2 yellow-green copper wire; equipment chassis bonded to the room ground bar 10 m $0 $0
18 KITOZER-PAC-TERM Terminal Block 5-pole 10A DIN-rail terminal block for indoor-outdoor wiring junction 1 set $0 $0
4. Air System
19 KITOZER-PAC-LOUV-S Double Adjustable Supply Air Grille Aluminum 600×150 mm, horizontal supply air, adjustable vanes 1 pc $56 $56
20 KITOZER-PAC-LOUV-R Return Air Grille with Filter Aluminum single-layer 500×200 mm, for bottom-return configuration 1 pc $42 $42
21 KITOZER-PAC-DEFLECT Air Deflector Adjustable aluminum deflector to avoid cold air blowing directly at the rack front 1 set $28 $28
22 KITOZER-PAC-FLT-G4 G4 Pre-Filter Washable polyester fiber, built into the indoor return air inlet 1 pc $28 $28
5. Installation Accessories
23 KITOZER-PAC-BRKT-W Indoor Wall-Mount Bracket 4# angle-steel welded, galvanized, load capacity >=80 kg, with expansion bolts 1 set $208 $208
24 KITOZER-PAC-BRKT-O Outdoor Unit Mounting Bracket 5# angle-steel welded, galvanized, load capacity >=100 kg, with anti-vibration pads 1 set $208 $208
25 KITOZER-PAC-BOLT Expansion Bolts M10x100 mm galvanized; to fix indoor and outdoor brackets 8 set $0 $0
26 KITOZER-PAC-PAD Rubber Anti-Vibration Pads 10 mm thick, 100×100 mm; under outdoor unit base for vibration/noise reduction 4 pc $0 $0
27 KITOZER-PAC-SEAL Neutral Silicone Sealant Waterproof & anti-mold; to seal wall penetrations 1 tube $14 $14
28 KITOZER-PAC-TIE Flame-Retardant Nylon Ties 4×200 mm; to bundle pipes and cables 1 pack $0 $0
Total — KITOZER Quotation Total (excl. tax) 28 items — — — $8,156

5. Optional Add-On Modules

No. Model Item Specification Qty Unit Unit Price (USD) Amount (USD)
1 KITOZER-PAC-HUM1 Electrode Humidification Module Humidification capacity 1 kg/h; for constant-temperature/humidity models 1 set $1,167 $1,167
2 KITOZER-PAC-HTR2 PTC Electric Heating Module 2 kW; supplementary heating for cold winter regions 1 set $625 $625
3 KITOZER-ENV-SNMP Environment Monitoring Module RS485/SNMP protocol; integrates into the room EMS 1 set $1,333 $1,333
4 KITOZER-PAC-AUTO Power-Fail Auto-Restart Module Auto-restores operation on power return; standard for unattended rooms 1 set $333 $333
5 KITOZER-PAC-FLT-G4-S Spare G4 Pre-Filter G4 pre-filter; spare for routine maintenance 2 pc $28 $56
Subtotal — Optional add-ons (selected as needed, not in main total) 5 items — — — $3,514

6. System Composition & Working Principle

The system has five parts: main units (wall-mounted indoor unit, air-cooled outdoor unit, LCD thermostat, NTC sensor); refrigerant piping (gas pipe φ12.7, liquid pipe φ6.35, elastomeric insulation, flare joints, condensate drain); electrical & control (dedicated power cable, shielded signal cable, leakage breaker, conduit, grounding, terminal block); air system (supply grille, return grille, deflector, G4 filter); and installation accessories (wall brackets, expansion bolts, anti-vibration pads, sealant, cable ties).

In operation, the NTC sensor on the indoor return-air side reads room temperature and compares it with the KITOZER-ENV-DH10 setpoint; the control board drives the inverter compressor and DC fan. Refrigerant absorbs sensible heat at the indoor evaporator and rejects it at the outdoor condenser. The supply grille delivers cool air horizontally, with an adjustable deflector avoiding cold air straight onto the rack front, forming an orderly airflow pattern that eliminates local hot spots.

7. Installation & Commissioning Notes

Indoor Unit Wall-mounted on a 4# angle-steel bracket with expansion bolts, level to ensure condensate drains freely
Outdoor Unit Wall or floor mounted on a 5# angle-steel bracket with anti-vibration pads; keep service and airflow clearance
Refrigerant Piping Copper tubes along wall/tray, B1 elastomeric insulation, wall penetrations sealed with neutral silicone
Electrical 220V dedicated circuit via a 2P 20A leakage breaker from the room distribution box; shielded signal cable between units; reliable chassis grounding
Commissioning Evacuate, charge refrigerant per standard; then power, communication, cooling, temp-accuracy and continuous stability tests

8. FAQ

What size room is a wall-mounted precision AC suitable for?
The typical 5 kW model suits a 4–5 m² room with about one standard rack (2–3 kW IT load), outdoor telecom cabinets and base stations. Sizing follows “environment load + equipment load × 1.2 safety factor”; the 5–12 kW range scales with rack power.
How is it different from a residential air conditioner?
A residential unit is tuned for comfort and dehumidification with a low sensible ratio, easily over-drying and causing condensation. The KITOZER precision unit has SHR ≥0.9, ±1°C control, 24/7 continuous-run design, G4 filtration, electronic expansion valve and inverter control matched to room sensible heat.
Does it need three-phase power?
No. The 5–12 kW wall-mounted series runs on 220V/50Hz single-phase, so ordinary room power suffices; it suits legacy sites and outdoor-cabinet retrofits without three-phase supply.
Can it do constant temperature and humidity?
Yes. The base model controls temperature to ±1°C; adding an electrode humidifier (1 kg/h) and PTC heater (2 kW) controls humidity within 40–60% RH at ±5%RH.
How do I connect it to a room environment monitoring system?
Add the environment monitoring module (RS485/SNMP) to upload temperature, humidity, running status and fault codes to the room EMS; a power-fail auto-restart module restores operation on power return for unattended sites.
Does the quotation include installation and freight?
The price is the equipment-material price (excl. tax), including a standard 10 m line set and common accessories. Installation, freight and taxes are quoted separately based on site distance and construction scope, by mutual agreement.