KITOZER
KITOZER

KITOZER Containerized Semi-Solid-State Energy Storage System Configuration

KITOZER Containerized Semi-Solid-State Energy Storage System Configuration

Model: KTR-ES Series (S / M / L) | 51.2 V DC | 30 / 40 / 50 kWh | IP65

Product Overview

The KITOZER KTR-ES containerized semi-solid-state energy storage system is an outdoor all-in-one ESS developed by Guangzhou Lai’an Intelligent System Development Co., Ltd. It uses semi-solid-state LFP cells (≥220 Wh/kg, ≥6000 cycles) in three energy tiers — 30 kWh, 40 kWh and 50 kWh — paired with a 30/40/50 kW bi-directional PCS that supports both grid-tied and off-grid operation.

The IP65 cabinet is built with a 3 mm BP500 ballistic-grade outer plate, a 5 mm aramid fiber buffer layer and a 2 mm cold-rolled inner plate, designed to GA141-2010 grade B protection. It suits outdoor PV plants, C&I storage, telecom backup, campus microgrids and remote high-security outdoor sites. The base has forklift slots and lifting lugs; the front is a double door, the right side a ventilation louver, and the left side an embedded service panel.

Product Lineup

Model Cabinet L×W×H (mm) Battery PCS Notes
KTR-ES-S30 1700×1600×1700 51.2V/150Ah × 4 modules ≈ 30 kWh 30 kW Front double door, right louver, plain left side
KTR-ES-M40 1800×1600×1800 51.2V/150Ah × 5 modules ≈ 40 kWh 40 kW Left embedded service panel (grille + round port)
KTR-ES-L50 2100×1600×2000 51.2V/150Ah × 6 modules ≈ 50 kWh 50 kW Left panel, 2×3 module layout

System Architecture

  1. Enclosure: Q235B rectangular tube frame, ballistic outer plate, aramid buffer, cold-rolled inner panel, double door, ventilation louver, channel-steel base, EPDM seals, outdoor polyester powder coat;
  2. Battery: 51.2V/150Ah semi-solid LFP modules on 6061-T6 aluminum brackets, T2 tin-plated copper busbars;
  3. BMS: Master + slave, 16–254 cells, CAN/RS485, accurate SOC/SOH estimation;
  4. PCS: 30/40/50 kW bi-directional, AC220V/380V compatible, ≥96% efficiency, grid-tied/off-grid;
  5. Thermal: IP65 circulation fans, PTC heater, NTC sensors, galvanized ductwork, module-to-module spread ≤±3 °C;
  6. Fire safety: S-type aerosol unit (3/4/5 kg), photoelectric smoke, rate-of-rise heat detector, CO detector, independent fire controller;
  7. Electrical auxiliaries: 24 VDC auxiliary supply, UK terminal blocks, armored power cables, copper ground busbar, IP65 glands;
  8. Monitoring: 7″ industrial touchscreen, data logger, 4G global module, Ethernet, IP65 suction antenna;
  9. Factory test: Visual, hipot, charge/discharge, IP65 seal, integrated test — per-unit report;
  10. Packaging: Steel-frame wooden crate with freight insurance.

Specifications

Item Value
Cell chemistry Semi-solid-state LFP
Energy density ≥220 Wh/kg
Cycle life ≥6000 cycles (80% DOD)
Rated voltage 51.2 V DC
Peak discharge 50C (10 s); recommended continuous 5C
Unit capacity 30 / 40 / 50 kWh
PCS rating 30 / 40 / 50 kW
PCS efficiency ≥96%
AC output AC 220V / 380V, 50 Hz, grid-tied / off-grid
BMS protection OVP/UVP/OCP/OTP/SCP, CAN/RS485
Ingress protection IP65
External protection GA141-2010 grade B ballistic (grade A / ceramic composite optional)
Fire system S-type aerosol + smoke/heat + CO detection
Communications 4G global / Ethernet, 5G optional
Operating temperature -20 °C to +55 °C (PTC heating for low temp)

Reference Configuration & Price

Model Capacity PCS Reference price per unit (incl. tax & freight)
KTR-ES-S30 30 kWh 30 kW ¥256,000 (≈US$35,600)
KTR-ES-M40 40 kWh 40 kW ¥330,000 (≈US$45,800)
KTR-ES-L50 50 kWh 50 kW ¥404,000 (≈US$56,100)

Prices include IP65 enclosure, GA141-2010 grade B ballistic protection, full system and freight; on-site installation and commissioning are not included. Upgrading to grade A ballistic / ceramic composite, raising continuous discharge to 10C/20C or adding liquid cooling will add 15%–50% per unit. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY). Prices are for reference only; actual quotation may vary.

Applications

  • C&I peak-shaving and demand charge management;
  • Outdoor PV/wind farm配套 storage;
  • 5G base station and edge-site backup / off-grid power;
  • Data center, hospital and industrial backup power;
  • Remote high-security outdoor sites, border outposts, oil-field data nodes;
  • Residential and small C&I PV+storage systems.

Installation & O&M Notes

Delivery: Custom orders typically take 45–60 days: 15 days for ballistic material procurement, 20 days for cabinet fabrication, 10 days for integration, 5 days for testing.

Foundation: C20 concrete slab, load ≥1500 kg/m², ≥800 mm clearance on all sides; grounding resistance ≤4 Ω.

Commissioning flow: hipot → charge/discharge test → grid-tied/off-grid switchover → BMS-PCS communication → fire linkage test → 4G uplink verification.

Warranty: 1-year whole-unit warranty, 3-year battery warranty, lifetime technical support.

Safety Architecture

The KTR-ES uses three layers of protection. At the cell level, the BMS monitors every voltage and NTC temperature, cutting contactors on over-voltage, under-voltage, over-current, over-temperature or short circuit. At the system level, DC and AC main breakers plus Class-II surge arresters (20 kA AC / 40–60 kA DC) protect the power path. At the enclosure level, an S-type aerosol unit, photoelectric smoke detector, rate-of-rise heat detector and a CO sensor (0–1000 ppm) provide early-warning and clean-agent suppression, backed by an independent fire controller that keeps running for ≥24 h on battery after a mains loss. The CO sensor is specifically tuned to the early thermal-decomposition gases that precede thermal runaway in LFP cells.

Semi-Solid-State Cell Advantages

Semi-solid-state LFP chemistry reduces liquid electrolyte content compared with conventional LFP by using solid or quasi-solid electrolyte composites. Energy density rises to ≥220 Wh/kg (typical liquid LFP is 160–180 Wh/kg), cycle life reaches ≥6000 cycles at 80% DOD, and thermal stability under nail penetration or crush is materially better than NMC. The 51.2 V platform matches mainstream PCS input ranges and can be paralleled to MWh-scale outdoor stations.

KITOZER KTR-ES containerized semi-solid-state energy storage system
[Render location: KTR-ES-L50 exterior / battery module layout / PCS touchscreen / multi-unit outdoor ESS farm]

Keywords: containerized energy storage, semi-solid-state battery, outdoor battery cabinet, 51.2V ESS, IP65 energy storage, PCS inverter, C&I storage, KITOZER KTR-ES

Meta Title: KITOZER Containerized Semi-Solid-State Energy Storage System Configuration

Meta Description: KITOZER KTR-ES containerized semi-solid-state ESS in 30/40/50 kWh, 51.2V LFP cells, IP65, 30/40/50 kW grid-tied/off-grid PCS. Reference configuration & price.

Meta Keywords: containerized ESS, semi-solid-state battery, outdoor battery cabinet, 51.2V storage, IP65, KITOZER

Contact: Guangzhou Lai’an Intelligent System Development Co., Ltd. | Tel/WhatsApp: +86 18520668845 | Web: gdlain.com | Address: Zhongrun Industrial Park, Shilou, Panyu, Guangzhou, China

Shopping Cart