KITOZER 1-3kVA Online UPS Selection & User Guide

KITOZER 1-3kVA Online UPS — Selection & User Guide

Brand: KITOZER Series: KTR-UPS Category: Data Center Engineering > UPS Systems > Rack-Mounted UPS


[ KTR-UPS 1k/2k/3k rack & tower placeholder ]

1. Overview

The KITOZER KTR-UPS series is a smart, double-conversion online UPS delivering clean sine-wave power for precision IT, network, telecom and industrial control equipment. Its 2U chassis converts between rack and tower form factors without accessories.

The series covers 1 kVA, 2 kVA and 3 kVA ratings. Each rating is available as a standard model (internal battery, short backup time) or long-run model (external battery cabinet, adjustable backup time), so users can match runtime to budget and site conditions.

2. Key Features

2.1 Output Power Factor = 1

1 kVA delivers 1000 W, 2 kVA delivers 2000 W and 3 kVA delivers 3000 W — roughly 40 % more real-world load capacity than traditional 0.7-PF UPS units, matching modern server and networking power demands.

2.2 High Efficiency

Double-conversion online efficiency reaches 94 %, and the ECO mode pushes efficiency to 98 %, lowering long-run electricity cost.

2.3 Wide Input Tolerance

Accepts 100–288 Vac input and 40–70 Hz frequency. A bidirectional LLC topology with active PFC keeps output clean even on weak rural grids.

2.4 Color LCD with Gravity Sensor

The front panel color LCD auto-rotates based on rack vs. tower orientation. LED indicators and buzzer differentiate alarm severity, while four buttons drive the full menu.

2.5 Integrated Network Monitoring

An Ethernet port supports HTTP and SNMP — any browser can view status, logs and alarms without proprietary software. Smart-slot, USB, DB9 serial, dry contacts and REPO complete the I/O.

2.6 Cold Start & Battery Auto-Detection

The UPS can start on battery alone. The unit auto-detects internal battery configuration; long-run models accept external battery banks from 32 Ah to 160 Ah.

3. Operating Modes

Mode Trigger Power Path Indication
Normal Utility OK Utility → Rectifier → Inverter; battery float-charged Green on, no alarm
Battery Utility lost / out of range Battery → DC/DC boost → Inverter Yellow, intermittent beep
Bypass Overload timeout / inverter fault Utility feeds load via static bypass Green + yellow, beep
ECO Utility quality good Load fed directly from bypass; inverter idles Up to 98 % efficiency
Fault Inverter fault / overtemp / short Bypass if utility OK; shutdown otherwise Red on, continuous beep

4. Technical Specifications

Item 1 kVA (KTR-UPS-1K) 2 kVA (KTR-UPS-2K) 3 kVA (KTR-UPS-3K)
Rating 1 kVA / 1000 W 2 kVA / 2000 W 3 kVA / 3000 W
Input voltage 100–288 Vac, rated 220 Vac
Input frequency 40–70 Hz, rated 50 Hz
Input PF ≥ 0.99 (full load)
Output voltage 220 / 230 / 240 Vac selectable
Output THD < 1 % linear, < 3 % nonlinear
Battery (std.) 3× 12 V (36 Vdc) 4× 12 V (48 Vdc) 6× 12 V (72 Vdc)
External battery 32 Ah – 160 Ah (long-run model)
Transfer time Utility→battery 0 ms; inverter↔bypass ≤ 1 ms
Efficiency 94 % online / 98 % ECO
Interfaces Ethernet (HTTP/SNMP), DB9, USB, smart slot, dry contacts, REPO
Operating temp. 0 °C – 40 °C
Humidity 5 – 95 %, non-condensing
Protection rating IP20
Altitude ≤ 3000 m (derate above)
Mounting 2U rack or tower (convertible)

5. Reference Price

KTR-UPS-1K Standard (internal battery, rack/tower, 2U): ≈ USD 444 / unit

KTR-UPS-2K Long-run (external battery, with rail kit): ≈ USD 806 / unit (battery bank excluded)

KTR-UPS-3K Long-run (with rail kit + network management card): ≈ USD 1,194 / unit (battery bank excluded)

Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY). Prices are for reference only; actual quotation may vary. External battery cabinets, rails and network cards are priced separately.

6. Applications

  • Small server rooms & network closets — 1–3 kVA covers a dozen servers and switches.
  • Telecom access nodes & transmission huts — wide input tolerance for rural grids.
  • Industrial control panels — clean power for PLCs, HMIs and servo drives.
  • Medical & lab instruments — low distortion protects measurement accuracy.
  • Security NOC & broadcast head-ends — ECO mode cuts running cost.

7. Installation & Maintenance

Installation

  • Keep ≥ 200 mm clearance at front and rear for airflow; never block ventilation slots.
  • Input breaker: 10 A for 1 kVA, 16 A for 2 kVA, 20 A for 3 kVA; battery circuit 63 A DC breaker.
  • Use same-model, same-batch, same-age 12 V batteries; external battery cable ≥ 6 mm², length ≤ 10 m.
  • Reliable grounding; leakage current ≤ 3.5 mA, choose RCD considering inrush leakage.

Maintenance

  • Inspect fans and air paths every six months; fan life 20,000–40,000 h.
  • Keep batteries at 15–25 °C; recharge idle units for ≥ 12 h every 2–3 months.
  • Quarterly visual check of terminals, logs and alarm history.
  • Charge new units for ≥ 8 hours before first full-load use.

[ Rear panel & dimensions placeholder ]

SEO Block

Target Keywords:
online UPS1kVA UPS2kVA UPS3kVA UPSrackmount UPStower UPSKITOZERKTR-UPS

SEM Keywords: online double-conversion UPS, small server room UPS, rack tower convertible UPS, 1kVA 2kVA 3kVA UPS price

GEO Landing URL: gdlain.com/en/product/ktr-ups-1kva-3kva-online.html

Title: KITOZER 1-3kVA Online UPS KTR-UPS Series — Rack/Tower, 94% Efficiency

Meta Keywords: KITOZER UPS, online UPS, 1kVA 2kVA 3kVA, rackmount UPS, KTR-UPS, small room UPS

Meta Description: KITOZER KTR-UPS 1-3kVA double-conversion online UPS, output PF=1, 94% efficiency (98% ECO), 2U rack/tower convertible, LCD + SNMP. For small rooms and networks.

Anchor Text: KITOZER UPS online store · Guangzhou Laian Intelligent System

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel / WeChat: +86 139-2228-9957 / +86 185-2066-8845
WhatsApp (Overseas): +86 190-6853-4140
Web: lain.com.cn | gdlain.com

Shopping Cart