ToggleKITOZER Custom Low-Voltage Power Distribution Cabinet — XL Series
Brand: KITOZER Series: KTR-PDC (XL-21 custom power cabinet) Category: Data Center Engineering > Power Distribution > Mains Distribution Cabinet
[ KTR-PDC-XL21 cabinet exterior & internal layout placeholder ]
1. Overview
The KITOZER KTR-PDC-XL21 is a custom low-voltage distribution cabinet built on the classic XL-21 power cabinet platform. It is engineered to match the actual site load capacity, number of outgoing feeders, installation space and monitoring requirements. The cabinet body is fabricated from 1.2–1.5 mm cold-rolled steel, CNC-bent and welded, then phosphated and electrostatically powder-coated for mechanical strength and corrosion resistance.
Inside, the cabinet integrates a main incoming MCCB, multiple outgoing miniature circuit breakers, a three-phase multifunction power meter, current transformers, indicator lights and operator controls. It is delivered ready for floor-standing installation in data centers, industrial plants, commercial buildings and outdoor substations, delivering distribution, protection, metering and monitoring in one package.
2. Cabinet Structure
| Section | Components | Function |
|---|---|---|
| Sheet-metal body | Main frame, front door (with view window), rear panel, side panels, top/bottom plates, lock, hinges, ground bolts, gasket, levelling feet | Mechanical support, IP30, anti-tamper |
| Busbar system | TMY-30×3 tinned copper incoming bar, N bar, PE bar, DMC insulators, phase-color shrouds, galvanized bolts | Current collection & phase segregation |
| Main incoming | 3P+N MCCB (thermal-magnetic trip) with external door handle | Main switch, overload & short-circuit protection |
| Outgoing feeders | 12 MCBs (C/D curve), 6 RCD modules (30 mA), 35 mm DIN rail, labels, terminal blocks | Load distribution & branch protection |
| Metering & signal | Three-phase multifunction meter, 3× 0.5-class CTs, phase indicator lamps, pushbuttons, voltage selector switch | V/I/P/E/frequency monitoring |
| Secondary wiring | BVR 1.5 mm² control wire, BVR 6/10/16/25 mm² power wire, PVC trunking, marker tubes, ties, heat-shrink, PG glands | Internal wiring & cable entry sealing |
| Cooling & protection | 2× top-mounted axial fans + filters, thermostat, busbar-area insulating barriers | Forced ventilation and finger-safe segregation |
| Accessories | Fasteners, yellow-green ground wire, warning labels, COC, test report, wiring schematic, manual | Delivery documentation |
3. Key Features
- Fully custom: cabinet size, feeder count, breaker brand, meter model can be tailored to project drawings; expansion spares reserved.
- Reliable busbar: T2 tinned copper, DMC flame-retardant insulators, phase-color shrouds against accidental contact.
- Three-tier protection: main MCCB + branch MCB + RCD, covering overload, short-circuit and earth-fault protection.
- Smart monitoring: three-phase multifunction meter displays V, I, P, E and frequency; optional RS485 Modbus.
- Forced cooling: thermostat-controlled top fans prevent heat accumulation.
- Safety compliant: dedicated PE bar, door-to-frame bonding, high-voltage warning labels; built to GB 7251 (IEC 61439) LV switchgear standards.
4. Typical Configuration (Standard 1200×450×1500)
| Item | Configuration | Qty |
|---|---|---|
| Main MCCB | 3P+N, thermal-magnetic, 100–225 A frame | 1 |
| Outgoing MCBs | 1P/3P, C/D curve, ≤ 63 A | 12 (2 spares) |
| RCD modules | 30 mA operating current | 6 |
| Multifunction meter | Three-phase V/I/P/E/frequency | 1 |
| Current transformers | 0.5 class, ratio matched to main breaker | 3 |
| Phase indicators | R/Y/G LED, AC220 V | 3 |
| Pushbuttons / selector | Momentary buttons, voltage selector | 2 + 1 |
| Cooling fans | AC220 V axial with thermostat | 2 sets |
5. Reference Price
KTR-PDC-XL21 Standard (1200×450×1500, 100 A main, 12 outgoing, meter + CTs): ≈ USD 1,361 / unit (tax & freight excluded)
KTR-PDC-XL21 Upgraded (225 A main, 24 outgoing, dual-source transfer, RS485 meter): ≈ USD 2,569 / unit (tax & freight excluded)
Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY). Prices are for reference only; actual quotation may vary. Breaker brand (Schneider / Chint / Delixi / ABB), cabinet size, special protection rating and outdoor weatherproof structure will affect final price.
6. Applications
- Data center / server-room PDU — mains distribution to UPS, CRAC and IT loads, integrated with environment monitoring.
- Industrial plants / production lines — distribution to machine tools, conveyors, fans and pumps.
- Commercial buildings / offices — floor distribution, air-conditioning power cabinets, lighting panels.
- Outdoor substations / kiosks — roof weatherproofing and IP54 variants for floor-standing outdoor use.
- Renewable / energy-station — LV distribution for PV combiner boxes and PCS systems.
7. Installation & Maintenance
Installation
- Floor loading ≥ 100 kg/m²; verticality ≤ 3 mm/m, levelness ≤ 2 mm/m.
- Cables enter through bottom entry ports sealed with PG glands; bending radius ≥ 10× cable diameter.
- Reliable grounding: ground resistance ≤ 4 Ω (≤ 1 Ω for combined bonding); door-to-frame PE jumpers installed.
- Upstream transformer capacity and short-circuit level must match MCCB breaking capacity (recommended ≥ 35 kA).
Maintenance
- Quarterly: check cabinet temperature, fan operation and terminal tightness.
- Semi-annual: clean busbars and insulating barriers; verify meter and CT secondary circuit.
- Annual: infrared thermography to detect hot spots on busbar joints and breaker contacts.
- Only licensed electricians may operate; de-energize, test and lock out before opening the cabinet.
[ One-line diagram & secondary schematic placeholder ]