KITOZER
KITOZER

KITOZER KTR-LC Immersion Cooling Demonstration Cabinets

KITOZER KTR-LC Immersion Cooling System (Demonstration Cabinets)

Brand: KITOZER Series: KTR-LC Category: Data Center Engineering > Precision Air Conditioning

Single-phaseleak-free mag-driveplate HXPLC controllevel/OT protect

1. Overview

The KITOZER KTR-LC line delivers two immersion-cooling demonstration cabinets. The desktop single-unit cabinet (about 600x550x900mm) targets DIY, gaming and education visitors; the mini rack-scale data-center cabinet (about 800x700x1100mm on swivel casters) targets IDC and compute-center clients. Both ship as complete units: fill with the customer’s own coolant and connect power to run.

A magnetic-drive pump circulates the coolant through a plate heat exchanger tied to external water, while the PLC auto-regulates temperature, pump start/stop and high/low-temperature plus level interlocks. A high-clarity acrylic front window lets visitors watch the submerged hardware and the flowing coolant, which is ideal for exhibitions, showrooms and customer site visits. Unlike fan-cooled racks, immersion transfers heat directly into a liquid that contacts the chips, so the demo visibly demonstrates how fans and ductwork shrink away while chip temperatures stay flat even under full load.

2. Key Features

Leak-free circulation

  • Seal-less magnetic pumps handle mineral oil or fluorinated fluid; 25 L/min desktop and 40 L/min rack units, quiet and corrosion-resistant.
  • Oil-resistant silicone seals around the whole cabinet plus a bottom spill tray prevent leaks from reaching the floor.

Constant-temperature heat exchange

  • Oil-water plate HX ties to mains water or a chiller to hold oil temperature steady; multi-point NTC probes measure layered oil temperatures.
  • Dual high/low-level protection triggers auto shutdown on low level, preventing dry-running and overflow.

Automated control

  • Digital or 7-inch touch HMI shows oil temperature, flow, load and status; multi-stage audible/visual alarms for over-temperature, low level and pump fault.
  • Insulated layered trays isolate server metal chassis to avoid internal shorting in the coolant.

Showroom-grade visibility

  • Waterproof RGB light strips and a shaped acrylic window highlight coolant flow and submerged boards, turning the unit into an exhibit rather than a black box.
  • A quick-fill port and bottom drain make swapping the customer’s own coolant fast and clean.

3. Specifications

Item Desktop unit Mini rack unit
Size ~600x550x900mm ~800x700x1100mm, on casters
Pump Mag-drive 25 L/min Mag-drive 40 L/min
Heat exchange Compact plate HX Industrial plate HX
Sensing NTC x2 Layered NTC x4
Demo hardware Desktop mobo/CPU/GPU submerged 1U submerged servers x4 layered
Control Digital thermostat + micro PLC 7″ touch + integrated PLC
Protection Low-level cutoff, OT alarm Hi/lo level, pump fault, filter clog

4. Reference Price

KTR-LC desktop immersion demo cabinet (complete): RMB 35,000-60,000 / set

KTR-LC mini rack immersion data-center demo cabinet (complete): RMB 90,000-150,000 / set

Reference prices only; final quotation applies. Based on exchange rate as of October 2026 (1 USD = 7.2 CNY), the desktop unit is roughly USD 4,900-8,300 and the rack unit roughly USD 12,500-20,800. Coolant is customer-supplied; pricing varies with demo hardware, heat-exchange area and custom window geometry.

Beyond exhibition use, the rack demonstrator doubles as a low-risk engineering test bed: clients can trial their own board layouts or coolant candidates in a sealed, monitored loop before committing to a full immersion retrofit. Because the loop is closed and instrumented, engineering teams collect repeatable temperature and flow data that supports later PUE and capacity studies.

5. Applications

  • Exhibitions and showrooms: visual proof of immersion cooling and PUE benefits.
  • IDC/compute validation: mini rack simulating data-center cluster conditions.
  • Education and training: university and vocational lab rigs.
  • DIY and gaming: desktop immersion retrofit demonstrations.

6. Installation & Maintenance

Commissioning

  • Position the unit, connect the water-loop and power, fill coolant through the port, set target oil temperature and auto-run.
  • Shipment includes a factory test report, tool kit, spare seals and consumable pack.

Maintenance

  • Check coolant level and clarity, and clean the inline filter periodically.
  • Calibrate temperature probes and level switches; drain and seal the fluid loop after long shutdowns.

Service notes

Each cabinet leaves the factory with a burn-in report and an on-site commissioning guide. We recommend operators log oil temperature at steady state so any drift over the months points early to a fouled filter or a weakening pump. The consumable pack (spare seals, probes, filter cartridges and light strips) keeps the exhibit running through years of tradeshows without sourcing custom parts.

SEO

Keywords:immersion coolingsingle-phasedemo cabinetsubmerged serverplate HXdata center liquid coolingmag-drive pumpKTR-LC

SEM: immersion cooling solution, liquid cooling demo price, single-phase tank, data center immersion retrofit, cooling test bench

GEO landing: gdlain.com/product/ktr-lc-immersion-cooling.html

Title: KITOZER KTR-LC Immersion Cooling System | Desktop & Rack Demo Cabinets

Meta Keywords: immersion cooling, single-phase, liquid cooling demo, submerged server, plate heat exchanger, data center liquid cooling, mag-drive pump, KTR-LC, KITOZER

Meta Description: KITOZER KTR-LC immersion cooling demo cabinets pair a desktop unit and a rack-scale demonstrator with magnetic pumps, plate heat exchangers, PLC temperature control and level/over-temperature protection.

Anchor text: KITOZER immersion cooling · liquid cooling solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER)
Tel / WeChat: +86 13922289957 / +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart