KITOZER KTR-FV Data Center Fire Protection and Ventilation

KITOZER KTR-FV Data Center Fire Protection and Ventilation

Brand: KITOZER Series: KTR-FV Category: Data Center Engineering

HFC-227ea gasdual smoke/heatEx axial fan70C damperrelief ventfire linkage

1. Overview

The KITOZER KTR-FV series integrates gas fire suppression, detection and ventilation for data centers, electrical rooms and archives. Suppression uses cabinet HFC-227ea units with dual smoke and heat detectors for two-stage alarm; exhaust uses explosion-proof axial fans interlocked with 70C fire dampers.

The system complies with GB50370 gas suppression design code and GB50116 fire alarm design code. Each protected zone has an emergency abort button, gas-release warning light and siren, with a 30 s pre-discharge delay for evacuation.

Fresh air and exhaust ducts are galvanized steel with fire dampers and manual/electric control, covering both daily ventilation and smoke extraction.

2. Key Features

Gas suppression

  • Cabinet HFC-227ea units, 90 kg / 120 kg fill, 2.5 MPa, including cylinder, nozzle, piping and valves, 3C certified.
  • HFC-227ea purity >=99.6%, colorless, residue-free and safe for electronics.

Detection and alarm

  • Photoelectric smoke + fixed-temperature 68C heat detection, two-stage alarm; wall-mount gas control panel to GB16806.
  • Emergency abort button with key switch; red gas-release warning light.

Ventilation and exhaust

  • Explosion-proof axial fan Exd II BT4, >=2500 m3/h, >=150 Pa; 70C fire damper fuses closed with signal feedback.
  • Mechanical relief vent 0.1 m2 protects the enclosure from discharge pressure.

Interlock

  • On alarm, shut down AC and dampers, delay 30 s then discharge; after discharge, start exhaust ventilation.
  • Distribution box with breakers and terminals centralizes power.

3. Specifications

Item Configuration A Configuration B
Item Specification
Extinguishant HFC-227ea, purity >=99.6%
Fill 90 kg / 120 kg
Storage pressure 2.5 MPa
Detectors Photoelectric smoke + 68C fixed heat
Pre-discharge delay 0-30 s adjustable
Explosion-proof fan Exd II BT4, >=2500 m3/h
Fire damper 70C fuse closes
Relief vent 0.1 m2 mechanical

4. Reference Prices

KTR-FV cabinet HFC-227ea 90 kg unit (detectors, panel, siren, piping): reference price USD 2,500~3,600 per set

KTR-FV Exhaust fan + 70C damper + relief vent (per zone): reference price USD 1,200~1,670 per zone

The above prices are reference prices only; the formal quotation prevails. Prices vary by configuration, quantity, site and tax treatment; volume projects can be discussed. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY).

5. Applications

  • Data center rooms: Gas protection for electronic equipment.
  • UPS and electrical rooms: Cable and equipment fire protection.
  • Archives and museums: Paper and artifact protection.
  • Battery rooms and storage: Explosion-proof exhaust and fire interlock.

6. Installation and Maintenance

Installation

  • Keep cylinder room ventilated; nozzle distance from ceiling and equipment to code; fire-stop duct penetrations.

Maintenance

  • Check agent weight and pressure yearly; clean detectors every two years; manually test dampers semi-annually.

Sizing tips

  • Small rooms use one 90 kg cabinet; large rooms combine multiple cabinets; battery rooms require Exhaust and H2 detection.

7. FAQ

  • Q: Does HFC-227ea damage electronics?
    A: No. It is colorless, non-conductive and residue-free, the preferred gas agent for server rooms.
  • Q: Why the 30 s delay?
    A: It allows evacuation and equipment interlock; the abort button can stop discharge during the delay.
  • Q: How many detectors per zone?
    A: At least one smoke and one heat detector for two-stage alarm: smoke warns, heat confirms and triggers discharge.
  • Q: When can people re-enter?
    A: After discharge, exhaust runs 15-30 minutes until agent concentration is safe.

8. Technology Trends

Data center fire protection is moving from sprinklers to gas suppression and very early smoke detection. KTR-FV integrates gas suppression, dual detection, Exhaust and relief vent to GB50370 and GB50116, and will add VESDA aspirating detection for incipient fire warning.

Additional Q&A

  • Q: Does HFC-227ea cause oxygen deficiency?
    A: Design concentration is 8%-9%, safe for short exposure; exhaust after discharge brings levels down.
  • Q: Does installation need a licensed contractor?
    A: Yes, fire-protection-qualified contractors install; KITOZER supports acceptance and training.
  • Q: Where is the relief vent?
    A: On the upper exterior wall, about 2/3 of room height, to protect the enclosure from discharge pressure.
  • Q: How do fans and dampers interlock?
    A: On alarm, AC and fresh air shut; after discharge, exhaust starts; the 70C damper fuses and reports back.

Data center fire protection favors early warning and clean agent suppression. KTR-FV integrates gas suppression, dual detection and mechanical exhaust to avoid secondary water damage. Future units will add VESDA aspirating detection and IoT remote fire monitoring.

KITOZER supports fire review and acceptance, providing 3C certificates, as-built drawings and manuals. After installation we run simulated discharge tests covering alarm, delay, discharge and exhaust, and train the duty staff.

SEO Information

Search keywords:HFC-227eagas suppressiondata center firesmoke heat detectorEx fanfire damperKTR-FVKITOZER

PPC keywords:HFC-227ea price,data center fire system,gas suppression unit,exhaust fan,KITOZER fire

GEO landing page:lain.com.cn/en/product/ktr-fv-fire-ventilation.html

Title:KITOZER KTR-FV Data Center Fire Protection and Ventilation

Meta Keywords:HFC-227ea,gas suppression,data center fire,smoke heat detector,explosion proof fan,70C damper,relief vent,KTR-FV,KITOZER

Meta Description:KITOZER KTR-FV data center fire and ventilation, cabinet HFC-227ea 90/120 kg, dual smoke/heat, Ex axial fan, 70C damper, relief vent interlock.

Anchor text:KITOZER by Laian · Data center solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER Brand)
Tel / WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Website: lain.com.cn | gdlain.com

Shopping Cart