Table of Contents
ToggleKITOZER KTR-TC Precision Air Conditioner and Thermal Control
Brand: KITOZER Series: KTR-TC Category: Data Center Engineering / Precision Cooling
precision ACdatacenter专用空调in-row ACtemperature humidity controlN+1 redundancyEC fanup/down discharge7×24 operation
1. Overview
The KITOZER KTR-TC precision AC family delivers 5-120 kW cooling for data centers and temperature-controlled rooms, in room-standing, in-row and rear-door forms. It runs 7×24 with +/-1 C and +/-5% RH control, far beyond comfort AC.
Systems use scroll compressors, EC fans, electronic expansion valves and hydrophilic fin coils, with up-/down-duct or in-row horizontal airflow. N+1 parallel redundancy and group control match rack load. RS485/TCP links to DCIM for return-air temp/humidity, compressor status and filter-differential pressure.
KTR-TC pairs with hot/cold aisle containment and rack blanking panels to raise efficiency and lower PUE; outdoor condensers support air, water or glycol options.
2. Key Features
Cooling and control
- Capacities: 5/12/20/30/45/60/90/120 kW.
- Temperature +/-1 C, humidity +/-5% RH; integrated reheat and humidification.
- EC fans save >30% energy vs AC fans with variable speed.
Reliability
- Scroll compressors with duty rotation; N+1 parallel redundancy.
- Dual power feeds with auto switch; alarm dry contacts + RS485.
- 7×23 design life >=100,000 hours, high MTBF.
Airflow and efficiency
- Room units up/down duct; in-row units push cold air to rack intakes.
- With containment and blanking panels, eliminate hot spots and lower PUE.
- Outdoor air-cooled condenser (-15 C cold start) or water/glycol.
3. Specifications
| Item | Config A | Config B |
|---|---|---|
| 型号 | KTR-TC-12(房间级12kW) | KTR-TC-R30(行间30kW) |
| 制冷量 | 12kW | 30kW |
| 送风 | 上送风/下送风 | 行间水平送风 |
| 温控精度 | ±1℃ | ±1℃ |
| 湿控 | ±5%RH(加湿+除湿) | ±5%RH |
| 风机 | EC离心风机 | EC直驱风机 |
| 压缩机 | 涡旋式 | 涡旋式,双压缩 |
| 通讯 | RS485 + TCP | RS485 + TCP |
| 电源 | 380V/50Hz | 380V/50Hz |
4. Reference Prices
KTR-TC-12 12 kW room-standing precision AC (up-duct, incl. indoor/outdoor units): Reference price USD 5,300~7,600 / unit (ref. CNY 38,000~55,000 at ~7.2 CNY/USD)
KTR-TC-R30 30 kW in-row precision AC (horizontal airflow, for N+1 set): Reference price USD 9,000~12,500 / unit (ref. CNY 65,000~90,000 at ~7.2 CNY/USD)
Prices are reference only; final quote depends on configuration, quantity, project location and tax. Bulk orders negotiable. Currency note: CNY to USD converted at approximately 7.2 CNY/USD for reference.
5. Applications
- Small/medium rooms: 12-30 kW room units with raised-floor plenum.
- High-density racks: 30 kW in-row units with aisle containment.
- Archives/museums: +/-1 C / +/-5% RH for paper preservation.
- Labs/QA: precision environment for equipment calibration.
6. Installation & Maintenance
Installation
- Keep indoor-outdoor refrigerant lift <=15 m; add oil charge for longer lines.
- Seal the raised-floor plenum; align in-row units with rack rows.
- Feed dual power from UPS and utility; daisy-chain N+1 group control.
Maintenance
- Clean filters monthly; inspect coils and refrigerant leaks quarterly.
- Every 6 months check compressor current, fan bearings and calibrate sensors.
- Winter air-cooled condensers need low-ambient kits or glycol.
7. FAQ
- Q: Precision vs residential AC?
A: Precision AC runs 7×23, controls both temp and humidity, high airflow low delta-T, with monitoring and redundancy; residential AC is intermittent and not suited to racks. - Q: Do I need N+1?
A: For critical rooms, yes. If one unit fails, the rest carry the load and avoid thermal shutdown. - Q: Down-duct or in-row?
A: Down-duct room units for low density (<5 kW/rack); in-row for high density (>8 kW/rack) with containment. - Q: What PUE can I reach?
A: With containment and EC fans, PUE reaches 1.4-1.5; liquid-cooled racks go lower.
8. Industry Trend & Selection
Precision cooling is shifting from room units to in-row, rear-door and liquid-cooling options, while PUE targets drive aisle containment and EC fans. KTR-TC covers 5-120 kW in room and in-row forms, with N+1 redundancy and group control to avoid hot spots in dense racks. Size cooling by rack IT load times 1.2, and lay out supply/return with hot/cold containment; use in-row or rear-door units for dense GPU racks. Clean filters monthly, calibrate temp/humidity sensors every six months, and check winter low-ambient kits on air condensers. DCIM monitors return-air temp/humidity and filter differential pressure in real time to catch cooling faults early.
9. Delivery & Service
KITOZER offers precision-AC selection, outdoor condenser installation, refrigerant brazing and group-control tuning as one service. We issue a cooling-layout drawing based on rack heat load and aisle containment, then commission indoor/outdoor units, power feed and DCIM integration. The warranty covers compressor and fan replacement; customers can add an annual maintenance package with filter change, refrigerant leak check and sensor calibration.
We provide a cooling-load calculation sheet and on-site commissioning of group-control and setpoints, and train facility staff on filter change and alarm response. Annual maintenance includes condenser cleaning and refrigerant pressure check.
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com