KITOZER KTR-CRAC Room-level Precision Air Conditioner

KITOZER KTR-CRAC Room-level Precision Air Conditioner

Brand:KITOZER Series:KTR-CRAC Category:Data Center Engineering / CRAC Cooling

CRAC precision ACCRAH air handlerdownflowupflowchilled waterEC plug fanhigh airflowroom-level

1. Overview

The KITOZER KTR-CRAC family delivers 60-200 kW room-level cooling for mid-to-large data centers and telecom rooms. Unlike in-row units mounted next to racks, CRAC/CRAH conditions air at room scale, using a raised-floor plenum or ceiling return airflow, suiting traditional low-to-medium-density rooms and retrofit projects.

Two forms are offered: direct expansion (DX) and chilled-water air handler (CRAH). DX units carry their own scroll compressor and outdoor condenser for small or standalone rooms. CRAH units have no compressor and rely on a central chiller for large, multi-room shared cooling with better efficiency and redundancy. Both use EC high-volume fans, electrode humidification and electric reheat, with +/-1 C and +/-5% RH control.

KTR-CRAC supports N+1 group control, dual power and leak detection, and links to DCIM for return-air temp/humidity, filter differential pressure and fan status.

2. Key Features

High airflow and airflow layout

  • High-airflow, low-delta-T design; supply air 14-18 C.
  • Downflow through raised floor to rack intakes; upflow via ceiling return.
  • With blanking panels and cold-aisle containment, eliminate plenum bypass and hot spots.

Cooling forms

  • DX: self-contained compressor, fast install, standalone rooms.
  • CRAH: shared chiller, multi-room redundancy, high efficiency.
  • Optional free cooling to exploit low outdoor temperatures in transition seasons.

Reliability and efficiency

  • EC fans variable speed; >30% energy saving vs fixed AC fans.
  • N+1 parallel; if one unit fails, others carry the load.
  • Filter differential alarm; leak rope along water pipes.

3. Specifications

Item Config A: KTR-CRAC-60 DX downflow Config B: KTR-CRAH-120 chilled water upflow
Cooling capacity 60 kW 120 kW (7/12 C chilled water)
Airflow downflow to raised floor upflow to ceiling return
Air volume 12,000 m3/h 24,000 m3/h
Fans EC centrifugal N+1 EC plug fan N+1
Coil DX scroll compressor 4-row chilled water coil
Humidification electrode electrode
Comms RS485/TCP RS485/TCP
Power 380V/50Hz 380V/50Hz

4. Reference Prices

KTR-CRAC-60 60 kW DX downflow unit (incl. outdoor condenser): Reference USD 7,600~11,100 / unit (ref. CNY 55,000~80,000 at ~7.2 CNY/USD)

KTR-CRAH-120 120 kW chilled-water upflow air handler (excl. chiller): Reference USD 13,200~19,400 / unit (ref. CNY 95,000~140,000 at ~7.2 CNY/USD)

Reference only; final quote depends on capacity, quantity, site and tax. Bulk projects negotiable. Currency: CNY at ~7.2 CNY/USD.

5. Applications

  • Traditional raised-floor rooms: downflow CRAC organizes plenum airflow.
  • Large data centers: chilled-water CRAH shares a central chiller plant.
  • Telecom central offices: continuous 7×24 with temp/humidity control.
  • Retrofits: add cooling without changing room structure.

6. Installation & Maintenance

Installation

  • Align floor cutouts with supply grilles; seal floor seams to prevent bypass.
  • Fit flexible connectors, strainers and 2-way valves on CRAH water pipes.
  • Keep DX indoor-outdoor lift <=15 m; ensure condenser airflow.

Maintenance

  • Monthly: clean/replace filters; quarterly inspect coil, refrigerant or water pressure.
  • Every 6 months: check EC fan current, belts and bearings; calibrate sensors.
  • Winter: low-ambient kit for DX; freeze protection for chilled water.

7. FAQ

  • Q: CRAC vs CRAH?
    A: CRAC has its own DX compressor; a CRAH is an air handler whose chilled-water coil exchanges heat and has no compressor.
  • Q: Downflow or upflow?
    A: Downflow with raised floor plenum; upflow with ceiling return if no floor.
  • Q: When use chilled water?
    A: Above ~300 kW or multi-room sharing; a central plant is more efficient and easier to redundant.
  • Q: What PUE?
    A: With containment, EC fans and free cooling, PUE reaches ~1.4.

8. Industry Trend & Selection

Room cooling is sharing the load with in-row, rear-door and liquid cooling, but CRAC/CRAH remain the workhorse for traditional rooms and retrofits thanks to high airflow, easy layout and low cost. KTR-CRAC covers 60-200 kW in DX and chilled-water forms with N+1 group control and leak monitoring. Size cooling at 1.2x IT load, seal the plenum and use blanking panels for downflow, and add in-row units for dense racks; for chilled-water projects coordinate chiller, pumps and thermal storage. Change filters and calibrate sensors on schedule, check free cooling and freeze protection in winter, and let DCIM track return-air temp and filter pressure in real time.

9. Delivery & Service

KITOZER offers airflow layout design, CRAC/CRAH selection, water and refrigerant piping and group-control tuning as one service. We issue a supply/return layout drawing based on heat load and raised-floor plan, then commission unit placement, power feed and DCIM integration. The warranty covers compressor, fan and coil replacement; an annual package includes filter change, refrigerant/water-pressure test and sensor calibration.

10. Airflow and Efficiency Notes

CRAC/CRAH efficiency depends heavily on airflow layout. Downflow systems use the raised floor as a plenum: cool air enters through front floor grilles and returns from the ceiling or top. If floor seams are unsealed or empty rack U positions lack blanking panels, cold air bypasses straight to the return, wasting cooling and creating hot spots. KTR-CRAC therefore ships with blanking panels, floor seals and cold-aisle containment so cold air enters only racks.

Chilled-water CRAH can add free cooling: when outdoor temperature is low, a plate exchanger uses cooling-tower water directly, cutting chiller run time and PUE. Design should coordinate chiller, pumps, plate exchanger and CRAH valve logic, and the monitoring platform should track supply/return water temperature and valve opening so the cooling plant runs efficiently year-round.

10. SEO Information

Search keywords:CRAC precision air conditionerCRAH air handlerdatacenter downflow unitchilled water CRAChigh airflow coolingKTR-CRACKITOZER

SEM keywords:[‘CRAC unit price’, ‘CRAH air handler’, ‘datacenter downflow AC’, ‘chilled water CRAC’, ‘high volume room cooling’, ‘KITOZER’]

GEO landing page:lain.com.cn/product/ktr-crac-room-air-conditioner.html

Title:KITOZER KTR-CRAC Room-level Precision Air Conditioner

Meta Keywords:CRAC precision air conditioner,CRAH air handler,datacenter downflow,chilled water cooling,high airflow unit,KTR-CRAC,KITOZER

Meta Description:KITOZER KTR-CRAC room-level precision AC, 60-200 kW, downflow/upflow, DX and chilled water versions, EC high-volume fans with raised floor and aisle containment.

Anchor:KITOZER by Guangzhou Laian · Data center solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart