Brand:KITOZER Series:KTR-GF Category:Data Center Engineering / Fire Protection
gas fire suppressionHFC-227eaFM200IG541clean agentcabinet unitpiped systemfire detection
1. Overview
The KITOZER KTR-GF gas fire suppression system protects data centers, server rooms, electrical rooms and archives with clean agents that leave no residue and are non-conductive, controlling fire quickly without damaging electronics — a key alternative to water sprinklers.
Two agents are offered: HFC-227ea (FM200) is highly effective with compact cylinder banks for small-to-medium zones; IG541 is an inert blend of nitrogen, argon and CO2 that produces no decomposition products, suiting larger zones and areas people may occupy. Forms include non-piped cabinet units placed directly in the hazard, and piped systems that distribute agent through piping and nozzles to multiple zones.
The system links to fire detection: dual detectors (smoke + heat) confirm an alarm, then after a 30 s delay discharge, while synchronously shutting down AC, dampers and doors, and sounding alarms to avoid injury and hold extinguishing concentration.
2. Key Features
Extinguishing performance
- HFC-227ea discharges <=10 s with fast flame knockdown and chemical inhibition.
- IG541 suppresses by physical oxygen reduction and cooling, no decomposition.
- Design concentration is calculated from zone volume with safety margin.
Safety and linkage
- Dual-detector cross-confirmation; 30 s delay before discharge after evacuation.
- Discharge closes ventilation, fire dampers and doors to hold concentration.
- Sounder/beacon, discharge indicator and abort switch are provided.
Zone adaptation
- Cabinet units suit small standalone rooms with no cylinder room.
- Piped systems share a bank across multiple zones cost-effectively.
- Zone leakage and pressure are checked per code.
3. Specifications
| Item | Config A: KTR-GF-FM cabinet HFC-227ea | Config B: KTR-GF-IG piped IG541 |
| Agent | HFC-227ea (FM200) | IG541 (N2/Ar/CO2 blend) |
| Cylinders | 100L cabinet, 15 MPa | 80L cylinder bank, 15/20 MPa |
| Design concentration | 8% | 37.5% |
| Discharge time | <=10 s | <=60 s |
| Suited to | small rooms / cabinets | large rooms / multiple zones |
| Form | non-piped cabinet | piped with nozzles |
| After discharge | residue-free, non-conductive | clean, non-conductive |
| Control | auto / manual / mechanical | auto / manual / mechanical |
4. Reference Prices
KTR-GF-FM cabinet HFC-227ea 100L (bank, detection linkage, nozzles; for 30-50 m3 zone): Reference USD 6,250~10,400 / set (ref. CNY 45,000~75,000 at ~7.2 CNY/USD)
KTR-GF-IG piped IG541 (cylinder room, piping, nozzles, multi-zone; for 100-200 m3): Reference USD 12,500~20,800 / set (ref. CNY 90,000~150,000 at ~7.2 CNY/USD)
Reference only; final quote depends on zone volume, nozzle count, site and tax. Bulk projects negotiable. Currency: CNY at ~7.2 CNY/USD.
5. Applications
- Data centers/server rooms: waterless, residue-free protection for electronics.
- Electrical rooms/cabinets: non-conductive for electrical fires.
- Archives/museums: safe for paper and artifacts.
- Telecom central offices: fast suppression in continuously running sites.
6. Installation & Maintenance
Installation
- Ventilate the cylinder room; anchor banks; slope piping correctly.
- Distribute nozzles evenly; seal door/window gaps per requirement.
- Mount detectors away from direct airflow dust and drafts.
Maintenance
- Monthly: check pressure gauges; refill if below green zone.
- Quarterly: test detectors and linkage logic, 30 s delay and valve action.
- Periodically have a qualified unit inspect and recharge agent per code.
7. FAQ
- Q: HFC-227ea vs IG541?
A: HFC-227ea for small zones (compact, lower cost); IG541 for large zones or high environmental needs (no decomposition). - Q: Is discharge harmful to people?
A: People evacuate before design concentration; IG541 is more forgiving; sounders and 30 s delay precede discharge. - Q: Do I need a cylinder room?
A: Cabinet units do not; piped systems need a dedicated cylinder room. - Q: How often to test?
A: Monthly gauge check, yearly linkage test, agent recharge by a qualified unit on schedule.
8. Industry Trend & Selection
Datacenter fire protection is moving from water sprinklers to clean agents and early smoke detection (VESDA-class), emphasizing early discovery, low loss and residue-free discharge. KTR-GF spans HFC-227ea and IG541 in cabinet and piped forms. Calculate agent volume from net zone volume and verify leakage/pressure; prefer cabinet HFC-227ea for small rooms and shared IG541 piping for large multi-zone rooms. Use smoke+heat confirmation and link to AC, dampers and access control. Monitor bank pressure monthly, test linkage yearly, and recharge by qualified personnel to keep the system ready.
9. Delivery & Service
KITOZER offers suppression design, agent quantity calculation, bank and piping installation and commissioning as one service. We issue nozzle layout and linkage logic drawings from the zone plan, then anchor banks, install piping and wire detectors and the control panel on site. The warranty covers bank and panel maintenance; customers can add an annual inspection and recharge package.
10. Design Codes and Safety Notes
Gas suppression must be designed from the zone net volume to calculate agent quantity, and verify enclosure leakage and pressure resistance. Discharge raises internal pressure; if walls or windows cannot withstand it, a pressure-relief vent or valve is required to keep overpressure within limits. HFC-227ea discharges within 10 s and IG541 within 60 s to reach extinguishing concentration before fire spread.
Safety requires three release modes: automatic (dual-detector cross-confirmation), manual (outside the room) and mechanical emergency (open cylinders directly if the panel loses power). Sounders and a 30 s delay precede discharge for evacuation. Monthly, check cylinder pressure; yearly, a qualified unit runs linkage tests and agent inspection so the system acts reliably when needed.
10. SEO Information
Search keywords:gas fire suppression systemHFC-227ea FM200IG541 inert gascabinet gas suppressionclean agent fire systemKTR-GFKITOZER
SEM keywords:[‘gas fire suppression price’, ‘HFC-227ea FM200 system’, ‘IG541 inert gas system’, ‘cabinet gas suppression unit’, ‘datacenter fire protection’, ‘KITOZER fire’]
GEO landing page:lain.com.cn/product/ktr-gas-fire-suppression.html
Title:KITOZER KTR-GF Gas Fire Suppression (HFC-227ea / IG541)
Meta Keywords:gas fire suppression system,HFC-227ea FM200,IG541 inert gas,cabinet gas suppression,clean agent fire system,datacenter fire,KTR-GF,KITOZER
Meta Description:KITOZER KTR-GF gas fire suppression, HFC-227ea (FM200) and IG541 clean agents, cabinet and piped forms, detection and alarm linkage, residue-free protection for electronics.