Brand: KITOZER Series: KTR-CRAC2 Category: Data Center Engineering / Room-level CRAC
room-level CRACdownflowupflowDX direct expansiontemperature humidityN+1 redundantEC fandatacenter AC
1. Overview
The KITOZER KTR-CRAC2 family delivers room-level precision cooling for data centers, telecom rooms and labs. Unlike in-row units beside racks, CRAC2 conditions the whole room through a raised-floor plenum or ceiling return, suiting low-to-medium-density rooms and new or retrofit projects.
Units use direct expansion (DX) with built-in scroll compressor and outdoor air-cooled condenser for fast, self-contained installation. Capacity ranges 25-100 kW per unit, supporting N+1 parallel group control; if one unit faults, the others carry the load for 7×24 continuous cooling.
CRAC2 includes EC centrifugal fans, electrode humidification and electric reheat, with +/-1 C and +/-5% RH control. It offers leak detection, dual power feeds and RS485/TCP comms to link into DCIM for return-air temp/humidity, filter pressure and compressor status.
2. Key Features
Room-level high airflow
- High-airflow, low-delta-T design; supply air 14-18 C.
- Downflow through raised floor to rack intakes; upflow via ceiling.
- With blanking panels and floor seals, eliminate bypass and hot spots.
DX refrigeration
- Scroll compressor, high EER, stable operation.
- Outdoor air-cooled condenser; low-ambient kit for cold climates.
- 25-100 kW per unit; N+1 parallel redundancy.
Temp/humidity control
- Electrode humidifier + electric reheat, independent control.
- EC fans variable speed; >30% saving vs fixed AC fans.
- Leak rope along unit base and water pipes; real-time alarm.
3. Specifications
| Item | Config A: KTR-CRAC2-30 (30 kW downflow) | Config B: KTR-CRAC2-80 (80 kW upflow) |
|---|---|---|
| Cooling capacity | 30 kW | 80 kW |
| Airflow | downflow to raised floor | upflow to ceiling return |
| Air volume | 6,000 m3/h | 16,000 m3/h |
| Compressor | scroll, single | scroll, twin parallel |
| Fans | EC centrifugal N+1 | EC centrifugal N+1 |
| Humidifier | electrode 5 kg/h | electrode 10 kg/h |
| Reheat | electric 6 kW | electric 12 kW |
| Power | 380V/50Hz/3P | 380V/50Hz/3P |
4. Reference Prices
KTR-CRAC2-30 30 kW downflow unit (incl. outdoor condenser): Reference USD 5,600~8,300 / unit (ref. CNY 40,000~60,000 at ~7.2)
KTR-CRAC2-80 80 kW upflow unit (incl. outdoor condenser): Reference USD 11,800~16,700 / unit (ref. CNY 85,000~120,000 at ~7.2)
Reference only; final quote depends on config, quantity, site and tax. Bulk projects negotiable. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Mid-small datacenters: room-level cooling with raised floor.
- Telecom central offices: 7×24 with temp/humidity control.
- Labs/instrument rooms: precision climate for stable equipment.
- Retrofits: add cooling without changing room structure.
6. Installation & Maintenance
Installation
- Level indoor unit; fit flexible connectors and valves on pipes.
- Outdoor condenser well ventilated; indoor-outdoor lift <=15 m.
- Align floor cutouts with grilles; seal floor seams.
Maintenance
- Monthly: clean/replace filters; quarterly inspect coil and refrigerant.
- Semi-annual: check EC fan current, belts, bearings; calibrate sensors.
- Winter: check low-ambient kit; pre-summer full service.
7. FAQ
- Q: CRAC2 vs in-row?
A: CRAC2 conditions the whole room; in-row sits beside racks for dense hot spots. - Q: Downflow or upflow?
A: Downflow with raised-floor plenum; upflow with ceiling return if no floor. - Q: How much IT does 30 kW cover?
A: Size at 1.2x IT load; 30 kW supports about 25 kW IT. - Q: Need N+1?
A: Critical rooms should use N+1 so others carry on a fault.
8. Trend & Selection
Room CRAC remains the workhorse for traditional rooms and retrofits. While high-density racks shift to in-row and liquid cooling, CRAC2 still dominates small-to-mid rooms and closets thanks to high airflow, easy layout and lower cost. Size at 1.2x IT load and plan N+1 for critical rooms; for downflow, seal the plenum and blank panels, or cold air bypass kills efficiency. Change filters and calibrate sensors on schedule, check low-ambient in winter, service before summer peaks, and let DCIM track return-air temp and filter pressure.
9. Delivery & Service
KITOZER offers heat-load calculation, CRAC2 selection, airflow design and on-site commissioning as one service. We issue a cooling layout drawing from room area and equipment kW, then complete indoor/outdoor placement, refrigerant piping and DCIM integration. The warranty covers compressor, fan and coil replacement; an annual package includes filter change, refrigerant test and sensor calibration.
10. Additional Notes
CRAC2 efficiency depends heavily on airflow. Downflow uses the raised floor as a plenum: cool air enters rack fronts and returns from ceiling/top. Unsealed floor seams or missing blanking panels let cold air bypass straight to the return, wasting cooling and creating hot spots. KTR-CRAC2 therefore ships with blanking panels, floor seals and cold-aisle containment so cold air enters only racks.
The outdoor condenser matters too. Mount it in a ventilated, shaded spot with clearance; when multiple condensers are lined up, keep spacing to avoid exhaust recirculation. Northern climates need a low-ambient kit or fan speed control so the system runs stably in winter.
Selection: for small-to-mid rooms (IT <=80 kW), prefer DX downflow CRAC2 for fast install and low cost; larger or multi-room projects may use chilled-water CRAH. In all cases size at 1.2x IT load and pair with containment and blanking to bring PUE down.
SEO Information
Search keywords:room level precision air conditionerCRAC unitdownflow precision ACDX datacenter ACconstant temp humidity ACKTR-CRAC2KITOZER
SEM keywords:room level precision AC price, CRAC unit, downflow datacenter AC, DX precision AC, constant temp humidity, KITOZER
GEO landing page:lain.com.cn/product/ktr-crac2-room-level-precision-air-conditioner.html
Title:KITOZER KTR-CRAC2 Room-level Precision Air Conditioner
Meta Keywords:room level precision air conditioner,CRAC unit,downflow precision AC,DX datacenter AC,constant temp humidity,KTR-CRAC2,KITOZER
Meta Description:KITOZER KTR-CRAC2 room-level precision AC, 25-100 kW, downflow/upflow, DX direct expansion, EC fans, N+1 group control, +/-1 C.