ToggleKITOZER KTR-DG Diesel Generator Set 100kW-1000kW Backup Power
Brand: KITOZER Series: KTR-DG Category: Power Distribution 2 / Diesel Generator
diesel generatorbackup power100-1000kWauto startATS transfersoundproof weatherproofparalleldatacenter
1. Overview
The KITOZER KTR-DG family provides emergency standby power for datacenters, hospitals, factories and telecom sites. From 100 to 1000 kW, each set pairs a turbocharged diesel engine with a brushless self-excited synchronous alternator, integrated control panel, fuel tank, muffler and cooling system, auto-starting and carrying load within 15 seconds of utility loss.
Three enclosures are offered: open set for plant rooms, soundproof canopy rated 75 dB(A) at 7 m for office buildings, and weatherproof cabin for outdoor ground installation with day tank, lubrication and exhaust, ready for paralleling.
KTR-DG ships with a smart controller for auto-start, auto-transfer, telemetry/telemetry/remote control and fault protection. Paired with an ATS automatic transfer switch, it delivers seamless utility-generator changeover. Multiple sets parallel to scale power and meet N+1 or 2N redundancy for Tier-grade datacenters.
2. Key Features
Auto-start and transfer
- Auto-start within 15 s; load on within 30 s.
- ATS dual-feed changeover <=100 ms mechanical.
- Cool-down shutdown and return to utility on restore.
Set performance
- Turbocharged aftercooled engine; low fuel consumption.
- Brushless alternator with AVR; +/-1% steady voltage.
- Options: battery charger, heater, float charger.
Noise and protection
- Soundproof canopy down to 75 dB(A) at 7 m.
- Weatherproof cabin IP54 for outdoor install.
- Built-in day tank (8-24 h); external tank optional.
3. Specifications
| Item | Config A: KTR-DG-150 (150 kW) | Config B: KTR-DG-500 (500 kW) |
|---|---|---|
| Standby power | 150 kW / 187.5 kVA | 500 kW / 625 kVA |
| Prime power | 135 kW / 168.75 kVA | 450 kW / 562.5 kVA |
| Engine | turbo diesel, 6-cyl | turbo aftercooled diesel, 12-cyl |
| Alternator | brushless self-excited, AVR | brushless self-excited, AVR |
| Voltage/freq | 400/230V, 50Hz | 400/230V, 50Hz |
| Start time | <=15 s | <=15 s |
| Noise (soundproof) | 75 dB(A) at 7 m | 78 dB(A) at 7 m |
| Tank endurance | 8-12 h day tank | 8-12 h day tank |
4. Reference Prices
KTR-DG-150 150 kW soundproof set (incl. ATS): Reference USD 11,800~18,100 / unit (ref. CNY 85,000~130,000 at ~7.2)
KTR-DG-500 500 kW weatherproof cabin set (incl. parallel panel): Reference USD 52,800~83,300 / unit (ref. CNY 380,000~600,000 at ~7.2)
Reference only; final quote depends on config, quantity, site and tax. Bulk projects negotiable. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter standby: carry load after utility loss; UPS bridges.
- Hospitals/OR: keep critical equipment powered.
- Factories: backup where grid is unstable.
- Remote telecom: sites with no or unreliable utility.
6. Installation & Maintenance
Installation
- Mount on anti-vibration pads; route exhaust outside with muffler.
- Isolate day tank from room by fire wall; use metal fuel lines.
- Ventilate intake/exhaust; keep outdoor cabin >=1.5 m from wall.
Maintenance
- Weekly no-load test; monthly loaded test.
- Change engine oil, fuel, oil and air filters on schedule.
- Check battery voltage/charging; rotate fuel to prevent aging.
7. FAQ
- Q: Standby vs prime?
A: Standby for emergencies, <=500 h/year; prime for continuous use. - Q: Can it carry UPS?
A: Yes; size generator at 1.2-1.5x UPS input to absorb inrush. - Q: Base for outdoor cabin?
A: Yes; concrete plinth, leveled, with cable and exhaust openings. - Q: Can sets parallel?
A: Yes; parallel panel included; scale N+1 or 2N as needed.
8. Trend & Selection
Standby power is evolving from diesel-only toward hybrid genset + UPS + storage, but diesel remains the mainstay for outages lasting hours to days. KTR-DG covers 100-1000 kW with paralleling and telemetry. Size at 1.2-1.5x UPS and critical load, accounting for inrush; datacenters should use N+1 or 2N and outdoor weatherproof cabins. Run loaded tests regularly, service filters and oil, check batteries and fuel so the set starts first time in a real outage.
9. Delivery & Service
KITOZER offers capacity calculation, set selection, base/exhaust design, ATS and switchgear supply, and on-site commissioning. We issue a power plan from the load list and utility reliability, then complete placement, exhaust piping and auto-transfer tuning. The warranty covers engine and alternator repair; an annual package includes filter service, loaded test and battery maintenance.
10. Additional Notes
Diesel generation is the last line of defense after utility loss, and its reliability decides business continuity. Many rooms size power correctly but skip loaded tests and fuel storage. KTR-DG’s smart controller logs every start, run hours and fault code for ops review.
On fuel, datacenters usually need at least 8 hours at full load; critical sites extend to 24-72 hours. The day tank sits in the cabin; external tanks need a leak-proof bund and fire protection. Rotate fuel every 6-12 months to avoid degradation that clogs injectors.
Selection: <=200 kW pick a single soundproof set; >=500 kW pick a weatherproof cabin with parallel-ready switchgear; datacenters configure N+1 or 2N. Always run loaded tests, not just no-load, or wet stacking and carbon buildup cause start-up failure when you need it most.