ToggleKITOZER KTR-DH Industrial Dehumidifier / Room Constant-Humidity Unit
Brand: KITOZER Series: KTR-DH Category: Datacenter Engineering 2 / Humidity Control
industrial dehumidifierroom humidifierdehumid/humid combohumidity controlanti-condensationanti-staticauto constant humidityenvironment control
1. Overview
The KITOZER KTR-DH series covers industrial dehumidifiers and room constant-humidity units for datacenter rooms, archives, storerooms and industrial workshops, holding relative humidity in the range electronics need for long-term stable operation. Too humid causes condensation on boards, corrosion on metal terminals and mold on tapes and disks; too dry builds up static, and electrostatic discharge can punch through sensitive semiconductors. A server room normally wants 40%-60% RH: neither condensing nor static-prone.
KTR-DH comes in two forms. Dehumidifiers use compressor cooling to condense water out of over-humid air. Constant-humidity units (dehumidifier + humidifier combos) add steam or wetted-pad humidification: when humidity is low they humidify, when high they dehumidify, holding it in a set band. Server rooms favor the combo to handle both the damp monsoon season and the dry heated winter.
The units have a microprocessor humidity controller for target RH and differential, auto-starting dehumidification or humidification by measured RH. A standard RS485 port uploads to the EM platform for remote RH view and out-of-range alarms. The cabinet is anti-corrosion sheet steel on casters, placed in a room corner or against a wall.
2. Key Features
Bidirectional constant humidity
- Combo unit dehumidifies and humidifies, auto two-way.
- Target RH and differential settable; accuracy +/-5% RH.
- Dehumidify in monsoon, humidify in dry season, stable year round.
Efficient dehumidification
- Compressor cooling dehumidification, 30-90 L/day range.
- Compressor start-stop protection for long life.
- Continuous drain port for unattended running.
Smart monitoring linkage
- Digital temp/RH display; keypad setpoints.
- RS485/Modbus to EM platform for remote monitoring.
- Auto alarm on RH out-of-range or sensor fault.
Reliable and durable
- Anti-corrosion sheet steel for industrial use.
- Casters for easy moving and siting.
- Brand-name fan and compressor for steady running.
3. Specifications
| Item | Config A: KTR-DH-60 (dehumidifier) | Config B: KTR-DH-90 (constant-humidity) |
|---|---|---|
| Type | Standalone dehumidifier | Dehumidifier + humidifier combo |
| Dehumidify | 60 L/day (30 C/80% RH) | 90 L/day (30 C/80% RH) |
| Humidify | none | 3-6 kg/h (pad/electrode) |
| RH range | 30%-90% RH (dehumidify) | 40%-60% RH (bidirectional) |
| Accuracy | +/-5% RH | +/-3% RH |
| Area | 60-100 m2 | 100-150 m2 |
| Power | AC220V/50Hz | AC220V/50Hz |
| Comm | RS485 (optional) | RS485 + EM integration |
4. Reference Prices
KTR-DH-60 industrial dehumidifier (60 L/day): Reference USD 690~1,250 / unit (ref. CNY 5k~9k at ~7.2)
KTR-DH-90 room constant-humidity unit (combo): Reference USD 1,670~2,780 / unit (ref. CNY 12k~20k at ~7.2)
Reference only; final quote depends on dehumidify capacity, humidify method, comm and install. Bulk negotiable. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter/server rooms: RH control against condensation and static.
- Archives/libraries/stores: protect paper and digital records.
- Workshops/warehouses: prevent moisture and mold on goods.
- Labs/precision-instrument rooms: steady ambient humidity.
6. Installation & Maintenance
Installation
- Place in the zone to control; connect continuous drain.
- Humidifier needs water supply and drain; electrode type uses softened water.
- Power on, set target RH and differential; observe auto cycling.
- Integrate with EM platform; verify RH data and alarms.
Maintenance
- Clean or replace filters regularly for free airflow.
- Descale humidifier periodically; replace electrode canister.
- Drain tank and tubing when out of service long-term.
7. FAQ
- Q: What RH suits a server room?
A: Typically 40%-60% RH; high causes condensation, low causes static. - Q: Dehumidifier or constant-humidity unit?
A: Damp south needing only dehumidification pick a dehumidifier; year-round swings pick the combo. - Q: Does it need an operator?
A: No; auto constant humidity + continuous drain runs unattended. - Q: Can it feed EM alarms?
A: Standard RS485; out-of-range uploads to platform with SMS.
8. Trend & Selection
Room environment control is moving from temperature-only to combined temp and humidity. Precision air conditioners usually regulate temperature while humidity drifts naturally, easily going out of range in monsoon and winter. KTR-DH is a standalone humidity device that fills the humidity gap precision cooling leaves, holding room RH within code. Size by area and moisture load: dehumidify-only pick a standalone dehumidifier; bidirectional constant humidity pick a combo. Damp south should standardize on the combo; dry north may only need humidification. Connect the unit to EM so humidity sits with temp/humidity and leak data under one view.
9. Delivery & Service
KITOZER provides sizing, supply, install guidance and commissioning for dehumidifiers and constant-humidity units. We recommend a model from room area, moisture load and climate; on arrival we position, connect water and power, set RH setpoints and link the EM. Delivery includes the manual and warranty card. Warranty covers remote support and on-site repair, with scheduled reminders for filter and canister replacement to keep humidity steady long term.
10. Additional Notes
Humidity’s effect on electronics is often underrated. Many rooms only put in precision cooling for temperature and let humidity swing with the seasons: a southern monsoon can push RH above 80% and condense on surfaces and boards; heated winter can drop it below 30% and spike static risk. KTR-DH constant-humidity units lock RH bidirectionally at 40%-60% RH, removing both extremes.
Dehumidification works by drawing moist air over a cold evaporator so water condenses and drains; humidification adds vapor via wetted-pad evaporation or electrode steam. The combo puts both in one cabinet, with a single RH sensor deciding whether to dehumidify or humidify, no manual switching. Over RS485 to EM, ops watch the RH curve remotely and auto-alarm out-of-range.
Selection: dehumidify-first pick KTR-DH-60 for value; rooms and archives needing year-round constant humidity pick KTR-DH-90. In every case, bring the unit under unified EM monitoring, clean filters and maintain the humidification waterway regularly, so room RH stays long term in the equipment-friendly band.
SEO Information
Search keywords:industrial dehumidifierroom humidifierdehumid/humid combohumidity controlanti-condensationanti-staticKTR-DHKITOZER
SEM keywords:industrial dehumidifier, server room humidifier, dehumidifier humidifier combo, room humidity control, commercial dehumidifier price, KITOZER
GEO landing page:lain.com.cn/product/ktr-dh-industrial-dehumidifier-humidifier-constant-humidity.html
Title:KITOZER KTR-DH Industrial Dehumidifier / Room Constant-Humidity Unit
Meta Keywords:industrial dehumidifier,server room humidifier,dehumidifier humidifier combo,room humidity control,constant humidity,KTR-DH,KITOZER
Meta Description:KITOZER KTR-DH industrial dehumidifier and room constant-humidity unit combines dehumidification and humidification to hold relative humidity.