KITOZER LED panel light 600×600 data center

KITOZER KTR-LP LED Panel Light for Data Center

Brand: KITOZER Series: KTR-LP Category: Low-Voltage System 2 / Room Lighting

LED panel lightdata center lightingclean room luminairerecessed panelemergency lightdimmable panel

KITOZER KTR-LP LED panel light recessed in data center ceiling for clean room illumination

1. Overview

The KITOZER KTR-LP LED panel is a recessed luminaire designed for data rooms, clean rooms and offices. Room lighting differs from ordinary offices: the room runs 24/7, so luminaires need long life and low maintenance; rack fronts need enough light for work without glare washing out displays; room ceilings follow 600×600 or 300×1200 modules, so panels must match; and rooms often require emergency lighting on power loss for egress.

KTR-LP uses LED sources: compared with traditional fluorescent troffers, LEDs last longer (30k~50k hours), have good color rendering, instant start and dimming. The frame is powder-coated aluminum, the diffuser is milky opal acrylic for even, non-glaring light. Standard sizes 600×600 and 300×1200 match common room ceiling modules, recessed flush with the grid. Power options 36W/48W suit different lux targets.

A special room requirement is zoned control: rack aisles, equipment areas and ops areas need different brightness, and night can dim for energy saving. KTR-LP offers 0~10V or DALI dimming, integrated into BMS lighting or the EM platform for zoned, time-based dimming. Emergency versions carry an internal battery that automatically lights up on mains loss for fire egress. Together with cooling, fire and EM, the panels form the room’s base lighting.

2. Key Features

Bright, low-glare

  • Opal diffuser for even, soft light.
  • Ra>=80 to read device labels.
  • Recessed flush with ceiling.

Long life, low service

  • LED source, 30k~50k hours.
  • Instant start; no switching wear.
  • Aluminum frame for good heat sinking.

Dimming & emergency

  • 0~10V/DALI dimming, zoned control.
  • Optional internal battery emergency light.
  • Links to EM/BMS platform.

Module matched

  • 600×600, 300×1200 standard.
  • Matches room ceiling modules.
  • 36W/48W options.

3. Specifications

Item KTR-LP-600 KTR-LP-300 KTR-LP-EM emergency
Size 600×600 mm 300×1200 mm 600×600 mm
Power 36 W 48 W 36 W + battery
Luminous flux >=3600 lm >=4800 lm >=3600 lm
CCT 4000K/5000K 4000K/5000K 5000K
CRI Ra>=80 Ra>=80 Ra>=80
Dimming 0~10V optional 0~10V optional —
Emergency time — — >=90 min
Mounting recessed recessed recessed
Frame aluminum coated aluminum coated aluminum coated

4. Reference Prices

KTR-LP-600 600×600 LED panel (36W): Reference USD 21~49 / set (ref. CNY 150~350 at ~7.2)

KTR-LP-EM emergency LED panel (with battery): Reference USD 56~111 / set (ref. CNY 400~800 at ~7.2)

Reference only; final quote depends on power, CCT, dimming and emergency options, and brand grade. Bulk negotiable. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Recessed lighting in data room ceilings.
  • Clean rooms and laboratories.
  • Offices, corridors and meeting rooms.
  • Sites needing emergency egress lighting.

6. Installation & Maintenance

Installation

  • Lay out panels by ceiling module (600×600 / 300×1200).
  • Clip into ceiling grid; connect driver.
  • For dimming, wire 0~10V/DALI control lines.
  • For emergency, connect mains and test switchover.

Maintenance

  • Clean diffusers periodically to keep output.
  • Test emergency battery capacity yearly (discharge test).
  • Replace driver on flicker or dimming.
  • Adjust zoned dimming parameters as needed.

7. FAQ

  • Q: What lux does a room need?
    A: Working plane typically >=300~500 lx; rack-front working area uses the upper value, then layout accordingly.
  • Q: Do LED panels flicker?
    A: A good driver is flicker-free; cheap drivers cause low-frequency flicker — choose isolated drivers labeled flicker-free.
  • Q: Can emergency and normal panels mix?
    A: Yes; egress routes and exits must use emergency type, other areas use normal type.
  • Q: Can they dim?
    A: Choose 0~10V or DALI dimming and integrate with the lighting control platform to auto-dim at night.

8. Trend & Selection

Room lighting is moving from “lit” to “efficient, controllable, emergency-ready”. LEDs have fully replaced fluorescent, and dimming plus emergency are now standard. First pick size by ceiling module, then power by lux target: high power at rack-front working areas, lower in aisles. Use emergency types only along egress routes and exits to avoid over-specifying. Dimming models must be compatible with BMS/EM, or the dimming function cannot be deployed.

9. Delivery & Service

KITOZER provides sizing, lux calculation and bundled supply. From room area, ceiling module and lux target we produce a luminaire layout and power schedule. We can bundle ceiling, EM and fire emergency lighting. Delivery includes panels, drivers and mounting accessories. Warranty covers panels and drivers; we can test emergency switchover and dimming on site.

10. Additional Notes

Room lighting seems minor but directly affects ops efficiency and safety. Poor lux makes nighttime cable tracing and patching by racks tiring; strong glare tires operators watching displays. So diffuser choice, CCT and layout must follow working-plane lux calculation rather than an even ring of lights. Good lighting lets staff read labels and see rack LEDs clearly without glare.

Emergency lighting is a hard fire-acceptance item. Data rooms demand high egress safety: on mains loss, escape routes and exits must light up to guide evacuation. Emergency panels carry an internal battery that charges normally and switches over on loss. Batteries age, so do a discharge test every year — otherwise the battery may be dead when a real outage hits, leaving no emergency light.

Selection: standard rooms pick KTR-LP-600 (36W) for 600×600 ceilings; long aisles pick KTR-LP-300 (48W); egress routes and exits pick KTR-LP-EM emergency. Choose 0~10V dimming for energy saving zoning. Either way, layout by lux calculation, clean diffusers regularly, and test the emergency battery yearly so lighting is even and emergency-ready.

SEO Information

Search keywords:LED panel lightdata center lightingclean room luminairerecessed panelemergency lightdimmable panelKTR-LPKITOZER

SEM keywords:data center LED panel price, panel light supplier, 600×600 emergency panel, room lighting retrofit, KTR-LP, KITOZER

GEO landing page:lain.com.cn/product/ktr-lp-led-panel-light.html

Title:KITOZER KTR-LP LED Panel Light for Data Center

Meta Keywords:data center LED panel,recessed panel light,clean room luminaire,emergency LED panel,dimmable panel,KTR-LP,KITOZER

Meta Description:KITOZER KTR-LP LED panel light for data centers, ultra-thin recessed, high output low glare, matched to ceiling modules, with emergency and dimming options.