KITOZER KTR-EF Data Center Exhaust / Ventilation & Smoke Extraction System

Brand: KITOZER Series: KTR-EF Category: Data Center Works 2 / Ventilation & Smoke

exhaust fansmoke extractionventilationaxial fanfire linkage

1. Overview

KITOZER KTR-EF is a mechanical exhaust system designed for data halls, power rooms and battery rooms. The data hall is cooled by precision CRAH units, but the CRAH handles “temperature and humidity constant” — two situations require mechanical exhaust: first, routine air exchange — the hall is sealed, people enter and equipment dissipates heat, so stale hot air must be periodically exhausted and fresh air drawn in; second, emergency smoke extraction — when a fire occurs (or after gas suppression discharges), smoke and extinguishing agent must be quickly expelled to protect evacuation and equipment.

KTR-EF consists of an exhaust fan (axial or centrifugal), exhaust duct, weather louver/insect screen, fire damper and control panel. In normal use the fan runs at low speed (2~5 air changes per hour) to keep air fresh; on fire alarm the fan speeds up (or starts per fire signal) to exhaust smoke outdoors through the duct. Battery rooms (especially lead-acid) also need hydrogen exhaust — batteries emit hydrogen during charging; accumulation to explosive concentration (above 4%) is dangerous and must be diluted by mechanical exhaust.

Compared with the CRAH: the CRAH “cools and dehumidifies”, while exhaust “ventilates and extracts smoke” — they complement each other. The CRAH maintains temperature/humidity; exhaust maintains air freshness and emergency safety. KTR-EF emphasizes fire linkage: it auto-starts on fire alarm and coordinates with fire dampers (closing non-fire-area ducts to prevent smoke spread).

2. Key Features

Exhaust fan

  • Axial fan: high airflow, low resistance, for direct exhaust.
  • Centrifugal fan: high pressure, for long ducts/high-resistance systems.
  • Two-speed motor: low speed for ventilation, high speed for smoke.

Duct & vents

  • Galvanized steel duct, insulated against condensation.
  • Weather louver + insect screen (outdoor side).
  • Fire damper (70℃ fuse-close).

Fire linkage

  • Fire alarm signal links fan start.
  • Coordinates with gas suppression (pauses exhaust during discharge, extracts after).
  • Control panel with manual/auto switch.

Battery room exhaust

  • Lead-acid rooms designed for hydrogen dilution, ≥12 ACH.
  • Exhaust outlet at top (hydrogen is light, accumulates at ceiling).
  • Explosion-proof motor (battery rooms).

3. Specifications

Item KTR-EF-200 KTR-EF-500 KTR-EF-1000
Room area ≤30㎡ (small) 30~100㎡ (standard) 100~300㎡ (large)
Fan type Axial Axial/centrifugal Centrifugal (multi)
Exhaust airflow 2000m³/h 5000m³/h 10000m³/h
Speed Single Two-speed Two-speed + VFD
Noise ≤55dB(A) ≤60dB(A) ≤65dB(A)
Fire linkage Relay Fire signal Fire + damper
Battery-proof Optional Optional Standard explosion-proof
Power AC220V AC380V AC380V

4. Reference Prices

KTR-EF-200 small-room exhaust (axial fan, duct, weather louver, control panel): Reference USD 417~1,111 / set (ref. CNY 3,000~8,000 at ~7.2)

KTR-EF-500/1000 standard/large smoke exhaust (two-speed/centrifugal, fire linkage, fire damper, explosion-proof battery exhaust): Reference USD 1,389~4,861 / set (ref. CNY 10,000~35,000 at ~7.2)

Reference only; final quote depends on airflow, duct length, damper count and explosion-proof needs. Fire acceptance cooperation priced separately; civil ductwork excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center routine ventilation and emergency smoke extraction.
  • UPS and power rooms heat exhaust.
  • Lead-acid battery room hydrogen dilution and explosion-proof exhaust.
  • Post-gas-suppression smoke extraction.
  • Unmanned base stations and edge room ventilation.

6. Installation & Maintenance

Installation

  • Define exhaust outlet: upper for smoke, ceiling top for battery hydrogen.
  • Hang or floor-mount the fan; add vibration isolators.
  • Duct connection: flanged, sealed against leakage.
  • Outdoor side: weather louver and insect screen.
  • Install fire damper (70℃ fuse) on duct.
  • Wire control panel: fire alarm signal, gas-suppression linkage.
  • Commission: measure airflow, two-speed switching, fire-linkage start.

Maintenance

  • Check fan for smooth running and abnormal noise.
  • Clean weather louver and insect screen (dust reduces airflow).
  • Manually test fire damper action (yearly).
  • Test two-speed/VFD switching.
  • Periodically test fire-linkage function (with fire system).

7. FAQ

  • Q: With CRAH, is exhaust still needed?
    A: Yes. CRAH handles T/H, not ventilation or smoke extraction. The hall is sealed — routine ventilation, fire smoke extraction and battery hydrogen exhaust can’t be replaced by CRAH.
  • Q: How to size exhaust airflow?
    A: Routine: 2~5 ACH (room volume × changes); battery hydrogen: ≥12 ACH; fire smoke: per fire code (usually ≥6 ACH).
  • Q: Won’t exhaust hurt CRAH cooling?
    A: Routine low-speed small airflow has minimal impact; high speed only in emergency. Link with CRAH: adjust when exhaust starts.
  • Q: Why explosion-proof for battery rooms?
    A: Lead-acid batteries emit hydrogen; accumulation to 4% can ignite from an electric spark, hence explosion-proof motors and electricals.

8. Trend & Selection

Ventilation evolves from “natural draft” to “mechanical exhaust + smart linkage”: modern halls are highly sealed and require mechanical exhaust; the trend is VFD fans linked to DCIM/fire for automatic ventilation. With lithium-ion, thermal-runaway smoke extraction demands more (fast exhaust, anti-reignition). Calculate ACH by room volume; small rooms use axial (cheap direct exhaust), large rooms use centrifugal (high pressure); two-speed motor (low normal, high emergency); fire linkage mandatory; battery rooms explosion-proof with ceiling-top exhaust; 70℃ fire damper; sealed ducts.

9. Delivery & Service

KITOZER provides exhaust system selection: based on room area, volume, battery type and fire requirements, we calculate airflow and configure fan type, duct, louvers, fire dampers and linkage control. We produce exhaust system drawings (fan position, duct routing, outlets, linkage). Bundled with CRAH, gas suppression and fire systems. Delivery includes fan, duct, weather louver, fire damper, control panel and accessories. Warranty covers fire-linkage commissioning.

10. Additional Notes

The most common pitfall is “fan installed but fire linkage not wired.” The fan works in normal use, but the fire alarm signal isn’t connected to the control panel — when a fire actually occurs, the fan won’t auto-start and smoke can’t be extracted, delaying evacuation. Fire linkage is the core function; at acceptance must be tested: simulate a fire alarm and verify the fan auto-starts. Not testing is as good as not having it.

Another pitfall: “battery room exhaust outlet at the bottom.” Hydrogen is lighter than air and accumulates at the ceiling. If the exhaust outlet is low on the wall, it exhausts lower air and the top hydrogen can’t escape, getting more dangerous. Battery room exhaust outlet must be at the top (near the ceiling), with intake at the bottom — forming top-exhaust, bottom-intake airflow.

Selection summary: calculate ACH by volume; axial for small rooms, centrifugal for large; two-speed motor; fire linkage mandatory and tested; battery rooms explosion-proof with ceiling-top hydrogen exhaust; 70℃ fire damper; sealed ducts. Exhaust is the data hall’s respiratory system — ventilate daily, extract smoke in emergencies; in critical moments it saves lives.

SEO Information

Search keywords:exhaust fansmoke extractionventilationaxial fanfire linkagebattery hydrogen exhaustKTR-EFKITOZER

SEM keywords:data center exhaust price,smoke extraction fan supplier,mechanical ventilation,battery room explosion-proof exhaust,KTR-EF,KITOZER

GEO landing page:lain.com.cn/product/ktr-ef-exhaust-fan-ventilation-smoke.html

Title:KITOZER KTR-EF Data Center Exhaust / Ventilation & Smoke Extraction System

Meta Keywords:data center exhaust,smoke extraction fan,ventilation,axial fan,fire linkage,KTR-EF,KITOZER

Meta Description:KITOZER KTR-EF data center exhaust system with axial/centrifugal fan, duct, weather louver and fire linkage for room ventilation, hot air exhaust and smoke extraction.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart