1. Overview
KITOZER KTR-FC is the “information highway” for high-speed data transmission. Copper cables don’t transmit far and have limited bandwidth; fiber uses optical signals — a single fiber carries tens of kilometers and tens to hundreds of Gbps. KTR-FC provides a full range: indoor fiber (for inside rooms and buildings), outdoor fiber (campus, aerial, duct, direct-burial), armored fiber (rodent/mechanical protection), and matching patch cords.
Fiber is single-mode or multi-mode: single-mode (OS2) has a thin core (9/125μm), transmits far (km to tens of km), uses lasers, suited to long backbones (between buildings, campus); multi-mode (OM3/OM4) has a thicker core (50/125μm), transmits near (hundreds of meters), uses LED/VCSEL, suited to inside rooms (switch to server, patch panel to equipment). KTR-FC selects by use: short in-room distances use OM3/OM4 multi-mode; building/campus long distances use OS2 single-mode.
Indoor fiber (e.g. GJFJV) is flexible, flame-retardant and bendable, routed in room trays and building risers; outdoor fiber (e.g. GYTA/GYTS) has PE jacket and steel armor, moisture/UV resistant, for aerial, duct or direct burial; armored fiber (e.g. GYTA53) is double-armored against rodents and mechanical damage, for direct burial or rodent-prone environments. Fiber counts range from 4 to 144 cores; size by active fibers plus spare redundancy.
2. Key Features
Fiber type
- Single-mode OS2 (9/125μm): long reach (≤10km), 10G/100G.
- Multi-mode OM3 (50/125μm, aqua/orange): 300m@10G.
- Multi-mode OM4 (50/125μm, violet/aqua): 550m@10G / 100m@100G.
Indoor fiber
- Tight-buffer, aramid reinforced, LSZH flame-retardant jacket.
- Flexible, bendable; for trays and risers.
- Commonly 4~24 cores.
Outdoor fiber
- GYTA (aluminum armor), GYTS (steel armor): moisture/UV resistant.
- Aerial, duct, direct-burial capable.
- 4~144 cores.
Armored & patch cords
- GYTA53 double-armored: burial, rodent-proof.
- Patch cords (LC/SC/FC/ST): room termination.
- LSZH; meets flame-retardant standards.
3. Specifications
| Item | KTR-FC-OM4 | KTR-FC-OS2 | KTR-FC-ARMORED |
|---|---|---|---|
| Type | Indoor MM OM4 | Outdoor SM OS2 | Armored SM |
| Fiber | 50/125μm OM4 | 9/125μm OS2 | 9/125μm OS2 |
| Jacket | LSZH | PE+steel armor | Double-armor+PE |
| Cores | 4~24 | 4~96 | 12~144 |
| Distance | 550m@10G | 10km@10G | 10km@10G |
| Installation | Indoor tray/riser | Aerial/duct | Burial/rodent |
| Color | Aqua | Black | Black |
| Connector | LC/SC (patch) | LC/SC/FC (splice) | LC/SC/FC (splice) |
4. Reference Prices
KTR-FC-OM4 indoor multi-mode (12-core, LSZH, per meter): Reference USD 0.7~2.1 / m (ref. CNY 5~15 at ~7.2)
KTR-FC-OS2/ARMORED outdoor/armored single-mode (24~48 core, steel/double armor, per meter): Reference USD 1.1~5.6 / m (ref. CNY 8~40 at ~7.2)
Reference only; final quote depends on core count, type (indoor/outdoor/armored) and ordered length. Full reels (1~2km) discounted; splicing, terminal boxes and patch cords extra. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center rack-to-rack and switch-to-server fiber links.
- Building vertical backbone (riser fiber).
- Inter-building aerial/duct campus fiber.
- Direct-burial backbone (armored, rodent-proof).
- Telecom base stations and video surveillance fiber.
6. Installation & Maintenance
Installation
- Select fiber type by distance and bandwidth (short MM, long SM).
- Count cores: active fibers + spare (~30% redundancy).
- Indoor: route along tray/riser; bend radius ≥10× cable diameter.
- Outdoor: aerial on messenger or in duct; burial uses armored, depth ≥0.8m.
- Splice: in terminal box/ODF; loss ≤0.1dB per point.
- Terminate: fit LC/SC patch cords to equipment ports.
- Test: measure link loss with power meter/OTDR; record.
Maintenance
- Clean connector end faces periodically (contamination raises loss).
- Maintain bend radius; no hard bends.
- Inspect outdoor jacket, messenger and marker posts.
- Spare cores unconnected but tested periodically.
- Troubleshoot splice/connector when link loss exceeds spec.
7. FAQ
- Q: Single-mode vs multi-mode?
A: By distance: in-room (≤550m) use multi-mode OM3/OM4; inter-building/campus (≥1km) use single-mode OS2. For bandwidth: short-reach 100G also uses OM4. - Q: How many cores per link?
A: Bidirectional: each optical port uses one transmit and one receive core (or a single-core bidirectional device). Count by equipment ports plus 30% spare. - Q: Can outdoor fiber go in indoor trays?
A: Outdoor jacket suits outdoors and can run indoor trays, but indoor flame-retardance requires LSZH — prefer indoor flame-retardant type. - Q: How much more is armored fiber?
A: About 30%~50% more than ordinary outdoor fiber, but rodent-proof and reliable for burial; rodent-prone or burial sites must use it.
8. Trend & Selection
Fiber evolves from “multi-mode primary” toward “single-mode long-reach + high bandwidth”: data centers move from 10G to 25G/100G/400G, with OM4/OM5 multi-mode and single-mode in parallel; the trend is high-density pre-terminated fiber (factory-terminated, plug-and-play on site, reducing field splicing) and space-division multiplexing (multi-core fiber). Use OM4/OM5 multi-mode for short high-bandwidth; OS2 single-mode for long backbone; count cores by ports +30% spare; indoor flame-retardant LSZH; outdoor aerial/duct GYTA; burial/rodent armored; reserve spare cores; field splicing to spec (≤0.1dB); keep patch end faces clean.
9. Delivery & Service
KITOZER provides fiber selection: based on distance, bandwidth, core count and installation method, we configure fiber type (OM3/OM4/OS2), jacket (indoor/outdoor/armored) and core count. We produce fiber backbone drawings (routing, core allocation, splice points). Bundled with ODF patch panels, terminal boxes and patch cords. Delivery includes fiber (by length), terminal boxes, splicing service and patch cords. Warranty includes link test reports and loss remediation.
10. Additional Notes
The most common pitfall is “dirty patch end faces nobody knows.” Fiber connector end faces (ceramic ferrule) with dust or grease drastically raise optical loss, making links intermittent. Many faults are not broken fiber but dirty end faces. Clean end faces regularly with a dedicated cleaner; clean before each mating. This is the most basic yet overlooked fiber maintenance step.
Another pitfall: “insufficient bend radius.” During routing or management, fiber is hard-bent to a small radius (less than 10× diameter), leaking light at the bend and raising loss. Fiber is not copper — bend radius has strict limits; armored fiber is stiffer, so leave generous arcs at turns.
Selection summary: short multi-mode OM4, long single-mode OS2; cores by ports +30% spare; indoor flame-retardant LSZH, outdoor GYTA, burial armored; bend radius ≥10× diameter; splice ≤0.1dB; keep patch end faces clean. Fiber is the data highway — a smooth road lets data run fast and stable.