KITOZER temperature humidity display monitor

KITOZER KTR-TDD Data Center Temp/Humidity Display Board

Brand: KITOZER Series: KTR-TDD Category: Environmental Monitoring 2 / Temp-Humidity Signage

temp humidity displaydata center signLED environment boardmonitoring displayKTR-TDD

1. Overview

KITOZER KTR-TDD temperature and humidity display board is the “signboard” of a data center environment. The monitoring system logs curves in the background, but when staff walk into the corridor, a large wall-mounted LED board shows “Temp 23.5°C Hum 48%RH” in big digits at a glance. KTR-TDD brings environmental data from the screen to the wall, visible during inspection, visits and audits.

The display itself is an aluminum-frame LED board built around ultra-bright numeric modules (red or green), with digit height from 2 to 8 inches chosen by viewing distance: 3 inches for a 3–5m corridor, 5–8 inches for a 10m+ hall. The board has a built-in temp/humidity probe (internal or remote) and can also connect via RS485/Modbus or Ethernet to the room’s DCIM/monitoring system, cycling through multiple sensors.

Beyond temp/humidity, the board shows time, date, equipment status (normal/alarm) and custom text (e.g. “Data Center — Authorized Personnel Only”). On alarm the digits flash red, alerting people on site. KTR-TDD is widely used in data center corridors, NOCs, archives, labs and electrical rooms.

2. Key Features

Display

  • Ultra-bright LED numeric modules, red or green.
  • Digit height 2/3/5/8 inches by viewing distance.
  • Visibility: 2 inch ~5m, 8 inch ~30m.

Data acquisition

  • Built-in probe (±0.5°C, ±3%RH).
  • Remote probe option, cable ≤10m.
  • RS485 Modbus-RTU / Ethernet TCP integration.

Content

  • Live temp and humidity values.
  • Time, date, weekday.
  • Multi-channel cycling when connected to monitoring.
  • Alarm digits flash and change color.

Structure & install

  • Aluminum frame + acrylic face.
  • Wall or flush mounting.
  • DC12V or AC220V supply.

3. Specifications

Item KTR-TDD-2IN KTR-TDD-3IN KTR-TDD-5IN
Digit height 2 inch 3 inch 5 inch
Visibility ≤5m ≤10m ≤20m
Content TH+time TH+time+date Multi-channel+custom text
Interface RS485 RS485/Ethernet RS485/Ethernet/USB
Power DC12V AC220V AC220V
Dimensions ~300×150mm ~500×200mm ~800×300mm
Mount Wall Wall/flush Wall/flush

4. Reference Prices

KTR-TDD-2IN 2-inch board (built-in probe, RS485, wall): Reference USD 111~208 / unit (ref. CNY 800~1500 at ~7.2)

KTR-TDD-3IN/5IN 3–5-inch board (Ethernet, multi-channel, wall/flush): Reference USD 208~486 / unit (ref. CNY 1500~3500 at ~7.2)

Reference only; final quote depends on digit height, interface, multi-channel and mount. Bulk corridor orders discounted. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center corridor entrance, displaying room environment.
  • NOC wall, supplementing the main screen with live data.
  • Archives, warehouses and labs.
  • Electrical rooms and UPS rooms.
  • Visits and audits showing environmental compliance at a glance.

6. Installation & Maintenance

Installation

  • Measure viewing distance; choose digit height (3 inch for 3–5m).
  • Mount height: board center 1.5–1.7m above floor.
  • Wall: fix bracket with anchors; hang the board.
  • Flush: cut a matching opening in wall/partition; insert and clip trim.
  • Wire: power (AC220V or DC12V) + RS485/Ethernet.
  • Link to monitoring: set Modbus address, map to sensors.
  • Power up; verify values and alarm flash.

Maintenance

  • Wipe face with a soft cloth; no alcohol or solvents.
  • Calibrate built-in probe every 6 months against a reference meter.
  • Check RS485 connector tightness.
  • If LED segments fail, replace mainboard.
  • Dust the internal power fan if fitted.

7. FAQ

  • Q: How does the board relate to the monitoring system?
    A: It can run standalone (own probe) or act as a monitoring display terminal. We recommend connecting to the system — one board cycles through many points, cheaper than a display per point.
  • Q: How to choose digit height?
    A: By max viewing distance: digit height (inches) × 2–3m = visibility. 5m corridor → 2 inch; 10m → 3–5 inch; 20m+ hall → 8 inch.
  • Q: Displayed value differs from the monitoring system. Why?
    A: First confirm which channel is shown (if cycling); then compare probe location — the wall probe and the in-rack probe read different micro-environments. To match, connect the board to read the same sensor.
  • Q: Can I customize text?
    A: Yes. Push custom text (room name, slogan) via USB or PC software; scrolls on boot.

8. Trend & Selection

Display boards evolve from “standalone meter” to “monitoring terminal + IoT sign”: early boards had their own local probe; today they connect to DCIM, cycling through a dozen points, and the board itself is network-monitored (board offline raises an alarm). The trend is paperless, visual, data-on-wall. Selection: pick digit height by viewing distance; 3 inch for corridor entrances, 5–8 inch for halls; choose RS485/Ethernet if integration is required; choose cycling model for multi-point; avoid direct sunlight (LED contrast drops); place probes where they are representative — not on an AC outlet.

9. Delivery & Service

KITOZER provides display selection: based on location, viewing distance and integration (standalone/network), we configure digit height, interface and content. Bundled with DCIM (KTR-EM series) to read system sensors directly. Delivery includes board, adapter, bracket/trim, comms cable and manual. Mainboard, power and probe faults are replaced free in warranty.

10. Additional Notes

The most common issue is “probe in the wrong place.” The board hangs on the wall, and so does its probe — it reads wall-area conditions, not what matters inside racks, cold aisles and hot aisles. A wall reading of 25°C can coexist with 35°C inside a rack. The wall board signs off the “overall room”; in-rack micro-environment data still relies on the monitoring system and rack sensors.

Another pitfall is direct sunlight. LED contrast collapses in direct sun — red digits become unreadable. Avoid west-facing windows, or add a sunshade. Mount height matters too: too high and visitors crane their necks, too low and racks block the view; 1.5–1.7m center height is most comfortable.

Selection summary: digit height by distance; connect to the same probe as monitoring; place probes representatively; avoid direct sun; mount at 1.5–1.7m; calibrate periodically. The display board is the data center’s “face” — once data is on the wall, environmental management becomes visible and verifiable.

SEO Information

Search keywords:temperature humidity displaydata center displayLED temp humidity boardmonitoring display terminalenvironment signboardKTR-TDDKITOZER

SEM keywords:temperature humidity display price,data center LED display supplier,DCIM display board,environment monitoring terminal,KTR-TDD,KITOZER

GEO landing page:lain.com.cn/product/ktr-tdd-temperature-humidity-display-board.html

Title:KITOZER KTR-TDD Data Center Temp/Humidity Display Board

Meta Keywords:temperature humidity display,data center environment display,LED temp humidity board,monitoring display terminal,KTR-TDD,KITOZER

Meta Description:KITOZER KTR-TDD data center temperature humidity LED display board, RS485/Ethernet to monitoring system, wall or flush mounted, for corridor and NOC environment sign-off.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart