KITOZER wall mount network cabinet 6U-12U

KITOZER KTR-WMC Wall-Mount Network Cabinet

Brand: KITOZER Series: KTR-WMC Category: Data Center Engineering / Wall Cabinet

wall mount cabinet6U/9U/12ULAN closetnetwork wall rackKTR-WMC

1. Overview

The KITOZER KTR-WMC is a small network cabinet hung on a wall — commonly called a wall-mount or wall cabinet. Server rooms use 42U freestanding racks, but floor telecom rooms, offices and shops only have a few switches, a patch panel and an ONT; there is no room (or budget) for a 2m rack. A wall-mounted 6U/9U/12U box does the job: it locks network gear inside a steel enclosure, anti-theft, anti-tamper, with tidy cabling.

Key parameters are U (height) and depth. U-count decides how many 19-inch devices fit: 6U holds one switch + one patch panel; 9U adds another; 12U holds three or four. Depth decides deep devices: ordinary switches are 200–300mm deep; wall cabinets come in 300/450/600mm, the deep end fitting a small UPS. Because it hangs, the cabinet can’t be too heavy — steel is thinner than a floor rack, and the loaded weight (tens of kg with gear) is held entirely by bolts and the wall. So the wall must be structural (solid brick/concrete); hollow drywall won’t hold.

Typical config: tempered-glass front door (lockable, to see gear), removable/rear-opening back panel (cabling), two 19-inch adjustable posts, top fan(s) for cooling, and a side-mount PDU. 6/9U for floor switches; 12U/15U for small rooms or office telecom closets. KTR-WMC spans 6U to 18U, black or white, matching floor racks.

2. Key Features

Structure

  • Welded cold-rolled steel, powder-coated.
  • 6/9/12/15U; depth 300/450/600mm.
  • 19-inch posts, depth adjustable.

Door & ventilation

  • Tempered-glass front door with lock (visibility).
  • Removable back panel or rear door (cabling).
  • Top 2–4 axial fans; optional thermostat.

Accessories

  • Side/top PDU (8 outlets).
  • Wall-hanger brackets with expansion bolts.
  • Cable-entry holes (top/bottom) with brush strips.

Safety

  • Locking door against tampering.
  • Grounding terminal.
  • Load-rated for full content (incl. UPS).

3. Specifications

Item KTR-WMC-6 KTR-WMC-9 KTR-WMC-12 KTR-WMC-15
Height 6U 9U 12U 15U
Size (mm) 600×450×350 600×450×450 600×600×600 600×600×750
Depth opt. 300mm 300/450 450/600 600mm
Door Glass front Glass front Glass front Glass front
Fans Top 1 Top 2 Top 2-4 Top 4
PDU Optional Optional 8-outlet std. 8-outlet std.
Holds switch+patch 2 switch+ODF 3-4 sw+small UPS small aggreg.

4. Reference Prices

KTR-WMC-6/9 small wall cabinet (6U/9U, glass door, brackets + fan): Reference USD 42~110 / unit (ref. CNY 300~800 at ~7.2)

KTR-WMC-12/15 deep wall cabinet (12U/15U, 600mm deep, PDU + 4 fans): Reference USD 125~250 / unit (ref. CNY 900~1800 at ~7.2)

Reference only; final quote depends on U, depth, PDU/fan/glass. Bulk (dozens per floor) discounted. Gear (switches, patch, UPS) priced separately; verify wall load on site. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Floor telecom room wall-mounted switch cabinet.
  • Offices, shops, supermarkets local LAN aggregation.
  • Surveillance NVR / DVR central storage.
  • Access-control and alarm-host enclosures.
  • Factory floors and warehouses — local network drops.

6. Installation & Maintenance

Installation

  • Inventory gear (switches, patch, NVR, small UPS); set U and depth.
  • Confirm wall: structural brick/concrete (hollow drywall needs reinforcement or a floor cabinet).
  • Drill to bracket holes; fit expansion bolts (loaded tens of kg; ≥M10).
  • Hang cabinet, level, tighten.
  • Mount top-down: heavy gear (UPS) low, switches mid, patch panel top for cable management.
  • Adjust posts to device depth; leave front/rear cabling space.
  • Power top fans and side PDU.
  • Enter cables via top/bottom brush holes; close and lock glass door.

Maintenance

  • Quarterly check lock, glass, wall bolts for looseness.
  • Clean fan dust (dust kills cooling).
  • Interior temp: if gear is hot, add fans in summer (or cautiously open door).
  • Keep cable labels clear; re-tidy on new gear.
  • After gear swaps, confirm cabinet load not exceeded.

7. FAQ

  • Q: 6U vs 9U?
    A: Count U: 1U switch, 1U patch panel, plus an NVR (maybe 2U). Typical floor: 2–3 switches + 1 patch = 5–6U; choose 9U for headroom; pick 12U if gear-heavy. Don’t buy exactly right — leave spare.
  • Q: Hollow/drywall OK?
    A: Not directly. Hollow brick or drywall can’t hold a loaded cabinet; it’ll pull out. Either reinforce (backing plate, through to solid layer) or switch to a small floor cabinet.
  • Q: Which depth?
    A: Ordinary access switches are 200–300mm deep; 450mm is enough. For a small UPS (>400mm) or patch+patch-manager combos, choose 600mm to leave cabling space front and rear.
  • Q: Need a fan?
    A: One or two low-power switches: natural convection is fine. Three to four units or an NVR (hot): add top fans. A sealed glass door in summer runs hot — fans are then mandatory.

8. Trend & Selection

Trends: “smart” and “install-simplified” — traditional wall cabinets are just boxes; now they add temp/humidity readouts, remote monitoring (web port for interior temp), smart PDUs; and pre-assembled cabinets (gear installed, cables dressed, labels applied at the factory, hung on site) cut on-site work. Selection: size U-count by gear +30% headroom; depth = deepest device +100mm; mount only on structural walls with M10+ bolts; put heavy gear low (lower center of gravity); add top fans for heat; lock the glass door.

9. Delivery & Service

KITOZER selects the wall cabinet from the device list (switches/NVR/patch/UPS) and site wall condition, recommending U, depth and accessories (PDU/fan). Pre-assembly (gear installed, cables dressed) is available. Delivery includes cabinet, hanger brackets, expansion bolts, fan and manual. Cabinet deformation, lock or fan faults are replaced free in warranty.

10. Additional Notes

The common pitfall is hanging on a non-load-bearing wall. Drywall partitions or hollow brick walls loaded with gear sag after six months and pull bolts out. Confirm the wall before install: structural walls get M10+ expansion bolts; hollow walls need a backing plate or a floor cabinet.

Second: buying exactly the right U. Planning two switches + one patch in a 6U, then two months later adding an AP controller or NVR — no room. Choose by existing gear +30%; 9U/12U cost little more than 6U.

Third: no cabling depth. Gear shoved to the back with cables plugging from the front won’t let the glass door close. Depth = device depth + 50–100mm front and rear; 600mm costs a bit more than 450mm but is far more usable.

Summary: U-count by gear with headroom; depth by deepest device; structural wall with M10 bolts; heavy gear low; fans for heat; lock the door. The wall cabinet is the floor network’s little closet — right size, right wall, and the floor switches hang there, trouble-free for years.

SEO Information

Search keywords:wall mount cabinetwall mount network6U 9U 12ULAN closetnetwork wall rackKTR-WMCKITOZER

SEM keywords:wall mount cabinet price,wall network cabinet supplier,6U network cabinet,12U wall cabinet,floor telecom closet,KTR-WMC,KITOZER

GEO landing page:lain.com.cn/product/ktr-wmc-wall-mount-network-cabinet.html

Title:KITOZER KTR-WMC Wall-Mount Network Cabinet / Small LAN Closet

Meta Keywords:wall mount cabinet,wall mount network cabinet,6U 9U 12U wall cabinet,small LAN closet,KTR-WMC,KITOZER

Meta Description:KITOZER KTR-WMC wall-mount network cabinet, 6U/9U/12U/15U, cold-rolled steel, fan and PDU, tempered glass front door, for telecom rooms, offices and floor switch closets.

Anchor: KITOZER by Guangzhou Laian · Data center engineering