ToggleKITOZER KTR-RLCD Rack Mount LCD Temperature Humidity Display
Brand: KITOZER Series: KTR-RLCD Category: Environmental Monitoring 2 / Rack Display Terminal
rack LCDtemp/humidity display1U displayaudible alarmKTR-RLCD
1. Overview
KITOZER KTR-RLCD is a rack-front environment display terminal mounted at a 1U position on the rack. Standing in front of a rack, technicians see temperature, humidity, leak, smoke and door-switch status at a glance — no PC, no web login. The screen is an LCD (or LED numeric) with large digits and adjustable brightness, readable even in dim data-center lighting.
KTR-RLCD is both collector and display: over an RS485 bus it polls multiple temperature/humidity sensors (one per rack or every two racks), leak-sensing cables, smoke detectors and door switches, summarizing them on screen. Buttons below the screen page through readings and set alarm thresholds. When a threshold is exceeded, the screen turns red and the buzzer sounds — on-site staff immediately know what tripped.
Beyond local display, KTR-RLCD uploads data via RS485/RS232 or Ethernet to a DCIM host software or cloud platform. The screen is the “on-site visualization” window and simultaneously a data-collection node for remote monitoring. It works with a room environment monitor host (KTR-EMC series): RLCD shows locally at every rack front; EMC concentrates in the main control room.
2. Key Features
Display & size
- 1U rack mount, upper front of the rack.
- LCD 3.5″ / 5″ / 7″ options.
- Adjustable backlight with ambient light sensor.
Acquisition channels
- RS485 bus, 16~32 sensors.
- Temp/humidity, leak, smoke, door, current.
- Modbus RTU.
Alarm
- Out-of-range: screen color change + buzzer.
- Relay output to siren/strobe.
- SMS/email uplink optional expansion.
Comm & power
- RS485/RS232 uplink; Ethernet optional.
- DC 12V or 220V supply.
- Button setup, no PC needed.
3. Specifications
| Item | KTR-RLCD-35 | KTR-RLCD-50 | KTR-RLCD-70 |
|---|---|---|---|
| Screen | 3.5″ LCD | 5″ LCD | 7″ TFT color |
| Mount | 1U rack | 1U rack | 1U rack |
| Sensors | 16 | 24 | 32 |
| Accuracy | ±0.5℃/±3%RH | ±0.5℃/±3%RH | ±0.3℃/±2%RH |
| Comm | RS485 | RS485/Ethernet | RS485/Ethernet/WiFi |
| Alarm | Buzzer+relay | Buzzer+relay | Buzzer+relay+SMS |
| Power | DC 12V | DC 12V | 220V |
4. Reference Prices
KTR-RLCD-35 3.5″ rack temp/humidity display (1U, RS485, 16 sensors, buzzer): Reference USD 83~167 / unit (ref. CNY 600~1200 at ~7.2)
KTR-RLCD-50/70 5/7″ color (Ethernet, SMS, 32 sensors): Reference USD 208~486 / unit (ref. CNY 1500~3500 at ~7.2)
Reference only; final quote depends on screen size, sensor count, comm (RS485/Ethernet/WiFi) and alarm method. Bulk rack-row discounted. Sensors, leak cable and adapter extra. Exchange: 1 USD ≈ 7.2 CNY (Oct 2026).
5. Applications
- Per-rack temp/humidity display in data centers.
- ELV room and network rack local visualization.
- Laboratory, warehouse and archive-room local monitoring.
- Unattended rooms: local alarm + remote uplink.
- Base stations and edge-compute nodes.
6. Installation & Maintenance
Installation
- Fix display at a 1U position (upper front).
- Power DC 12V from PDU/socket.
- Daisy-chain sensors on RS485 (A/B).
- Set DIP addresses 1~32 on each sensor.
- Display auto-scans online sensors.
- Set high/low alarm thresholds per sensor.
- Run uplink RS485 to monitor host/gateway.
- Test: simulate high temp; verify color change and buzzer.
Maintenance
- Quarterly calibration against a reference meter.
- Clean screen; no solvents.
- Check RS485 terminals.
- Test buzzer monthly.
- If a sensor drops, check address conflict and bus wiring.
7. FAQ
- Q: RLCD vs environment monitor host?
A: RLCD is a rack-local display+collector at each rack front; the EMC host concentrates in the main room for global logging, reports and remote notification. RLCD handles on-site alarm and visualization; EMC handles central management. - Q: How long can the RS485 bus run?
A: RS485 up to 1200m theoretically; keep under 800m in practice. Daisy-chain (no star), add 120Ω termination at both ends. Add a repeater beyond that. - Q: How many temp/humidity sensors per screen?
A: 16 for 3.5″, 32 for 7″. Each sensor needs a unique RS485 DIP address. Typically one sensor per rack at return-air or supply-air position. - Q: How to respond to an alarm?
A: Read which sensor and what value tripped. High temp: check AC airflow, door closure, hot/cold aisle containment; low humidity: humidifier; leak: AC drain pipe; smoke: evacuate and notify fire brigade.
8. Trend & Selection
Rack displays evolve from “LED numeric (one number)” to “TFT color (graphical, multi-point)”: early screens showed a single temperature; today’s show 12 temp/humidity points and leak status for a row on one screen. Trends: color, Ethernet, cloud integration. Selection: small racks use 3.5″ segment display; multi-rack rows use 7″ color with a floor-plan graphic; comm per existing system (RS485 legacy, Ethernet new); local buzzer is mandatory (unmanned sites also need remote SMS); size sensors by rack count +20% spare.
9. Delivery & Service
KITOZER provides selection: based on rack count, sensor types (temp/humidity/leak/smoke) and uplink (RS485/Ethernet), we configure screen size and expansion modules. Delivery includes display, ears, adapter, RS485 terminals and manual. Screen, collector board and buzzer replaced free in warranty. Bundled with temp/humidity sensors (KTR-THS), leak cable (KTR-LK) and EMC host (KTR-EMC).
10. Additional Notes
The most common pitfall is sensor placement. The temp/humidity sensor is stuck on the rack rear or AC supply outlet — measuring AC supply air, not server inlet air, so readings look fine while servers overheat. Put the sensor on the rack inlet (cold-aisle side), at the middle third where servers draw air; that is the real inlet temperature.
The second pitfall is bad RS485 wiring. Daisy-turned into star branches, A/B swapped, no termination — the bus intermittently drops and values jump. RS485 must be a single daisy chain with all devices parallel on A/B, and 120Ω resistors at both ends.
Third pitfall: thresholds set too wide. Setting high-temp alarm at 35℃ means servers already throttle by then. Recommended 18~27℃ per ASHRAE; set pre-alarm at 28℃ and critical at 32℃, leaving reaction time.
Selection summary: screen size by point count; sensors at the inlet; daisy-chain RS485 with termination; leave threshold margin; local buzzer plus remote SMS. The rack screen is the technician’s eyes — a glance at the rack beats logging into a PC.
SEO Information
Search keywords:rack mount LCDtemp humidity display1U rack displaydata center displayaudible alarmKTR-RLCDKITOZER
SEM keywords:rack temp humidity display price,rack LCD supplier,DCIM display,KTR-RLCD,KITOZER
GEO landing page:lain.com.cn/product/ktr-rlcd-rack-lcd-temperature-humidity-display.html
Title:KITOZER KTR-RLCD Rack Mount LCD Temperature Humidity Display
Meta Keywords:rack mount LCD,temperature humidity display,rack environment display,1U rack display,audible alarm,KTR-RLCD,KITOZER
Meta Description:KITOZER KTR-RLCD 1U rack LCD display shows temperature, humidity, leak and smoke status with audible alarm, RS485 uplink to DCIM.
Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com