KITOZER
KITOZER

KITOZER rack LCD display temperature humidity monitor

KITOZER KTR-RLCD Rack Mount LCD Temperature Humidity Display

Brand: KITOZER Series: KTR-RLCD Category: Environmental Monitoring 2 / Rack Display Terminal

rack LCDtemp/humidity display1U displayaudible alarmKTR-RLCD

1. Overview

KITOZER KTR-RLCD is a rack-front environment display terminal mounted at a 1U position on the rack. Standing in front of a rack, technicians see temperature, humidity, leak, smoke and door-switch status at a glance — no PC, no web login. The screen is an LCD (or LED numeric) with large digits and adjustable brightness, readable even in dim data-center lighting.

KTR-RLCD is both collector and display: over an RS485 bus it polls multiple temperature/humidity sensors (one per rack or every two racks), leak-sensing cables, smoke detectors and door switches, summarizing them on screen. Buttons below the screen page through readings and set alarm thresholds. When a threshold is exceeded, the screen turns red and the buzzer sounds — on-site staff immediately know what tripped.

Beyond local display, KTR-RLCD uploads data via RS485/RS232 or Ethernet to a DCIM host software or cloud platform. The screen is the “on-site visualization” window and simultaneously a data-collection node for remote monitoring. It works with a room environment monitor host (KTR-EMC series): RLCD shows locally at every rack front; EMC concentrates in the main control room.

2. Key Features

Display & size

  • 1U rack mount, upper front of the rack.
  • LCD 3.5″ / 5″ / 7″ options.
  • Adjustable backlight with ambient light sensor.

Acquisition channels

  • RS485 bus, 16~32 sensors.
  • Temp/humidity, leak, smoke, door, current.
  • Modbus RTU.

Alarm

  • Out-of-range: screen color change + buzzer.
  • Relay output to siren/strobe.
  • SMS/email uplink optional expansion.

Comm & power

  • RS485/RS232 uplink; Ethernet optional.
  • DC 12V or 220V supply.
  • Button setup, no PC needed.

3. Specifications

Item KTR-RLCD-35 KTR-RLCD-50 KTR-RLCD-70
Screen 3.5″ LCD 5″ LCD 7″ TFT color
Mount 1U rack 1U rack 1U rack
Sensors 16 24 32
Accuracy ±0.5℃/±3%RH ±0.5℃/±3%RH ±0.3℃/±2%RH
Comm RS485 RS485/Ethernet RS485/Ethernet/WiFi
Alarm Buzzer+relay Buzzer+relay Buzzer+relay+SMS
Power DC 12V DC 12V 220V

4. Reference Prices

KTR-RLCD-35 3.5″ rack temp/humidity display (1U, RS485, 16 sensors, buzzer): Reference USD 83~167 / unit (ref. CNY 600~1200 at ~7.2)

KTR-RLCD-50/70 5/7″ color (Ethernet, SMS, 32 sensors): Reference USD 208~486 / unit (ref. CNY 1500~3500 at ~7.2)

Reference only; final quote depends on screen size, sensor count, comm (RS485/Ethernet/WiFi) and alarm method. Bulk rack-row discounted. Sensors, leak cable and adapter extra. Exchange: 1 USD ≈ 7.2 CNY (Oct 2026).

5. Applications

  • Per-rack temp/humidity display in data centers.
  • ELV room and network rack local visualization.
  • Laboratory, warehouse and archive-room local monitoring.
  • Unattended rooms: local alarm + remote uplink.
  • Base stations and edge-compute nodes.

6. Installation & Maintenance

Installation

  • Fix display at a 1U position (upper front).
  • Power DC 12V from PDU/socket.
  • Daisy-chain sensors on RS485 (A/B).
  • Set DIP addresses 1~32 on each sensor.
  • Display auto-scans online sensors.
  • Set high/low alarm thresholds per sensor.
  • Run uplink RS485 to monitor host/gateway.
  • Test: simulate high temp; verify color change and buzzer.

Maintenance

  • Quarterly calibration against a reference meter.
  • Clean screen; no solvents.
  • Check RS485 terminals.
  • Test buzzer monthly.
  • If a sensor drops, check address conflict and bus wiring.

7. FAQ

  • Q: RLCD vs environment monitor host?
    A: RLCD is a rack-local display+collector at each rack front; the EMC host concentrates in the main room for global logging, reports and remote notification. RLCD handles on-site alarm and visualization; EMC handles central management.
  • Q: How long can the RS485 bus run?
    A: RS485 up to 1200m theoretically; keep under 800m in practice. Daisy-chain (no star), add 120Ω termination at both ends. Add a repeater beyond that.
  • Q: How many temp/humidity sensors per screen?
    A: 16 for 3.5″, 32 for 7″. Each sensor needs a unique RS485 DIP address. Typically one sensor per rack at return-air or supply-air position.
  • Q: How to respond to an alarm?
    A: Read which sensor and what value tripped. High temp: check AC airflow, door closure, hot/cold aisle containment; low humidity: humidifier; leak: AC drain pipe; smoke: evacuate and notify fire brigade.

8. Trend & Selection

Rack displays evolve from “LED numeric (one number)” to “TFT color (graphical, multi-point)”: early screens showed a single temperature; today’s show 12 temp/humidity points and leak status for a row on one screen. Trends: color, Ethernet, cloud integration. Selection: small racks use 3.5″ segment display; multi-rack rows use 7″ color with a floor-plan graphic; comm per existing system (RS485 legacy, Ethernet new); local buzzer is mandatory (unmanned sites also need remote SMS); size sensors by rack count +20% spare.

9. Delivery & Service

KITOZER provides selection: based on rack count, sensor types (temp/humidity/leak/smoke) and uplink (RS485/Ethernet), we configure screen size and expansion modules. Delivery includes display, ears, adapter, RS485 terminals and manual. Screen, collector board and buzzer replaced free in warranty. Bundled with temp/humidity sensors (KTR-THS), leak cable (KTR-LK) and EMC host (KTR-EMC).

10. Additional Notes

The most common pitfall is sensor placement. The temp/humidity sensor is stuck on the rack rear or AC supply outlet — measuring AC supply air, not server inlet air, so readings look fine while servers overheat. Put the sensor on the rack inlet (cold-aisle side), at the middle third where servers draw air; that is the real inlet temperature.

The second pitfall is bad RS485 wiring. Daisy-turned into star branches, A/B swapped, no termination — the bus intermittently drops and values jump. RS485 must be a single daisy chain with all devices parallel on A/B, and 120Ω resistors at both ends.

Third pitfall: thresholds set too wide. Setting high-temp alarm at 35℃ means servers already throttle by then. Recommended 18~27℃ per ASHRAE; set pre-alarm at 28℃ and critical at 32℃, leaving reaction time.

Selection summary: screen size by point count; sensors at the inlet; daisy-chain RS485 with termination; leave threshold margin; local buzzer plus remote SMS. The rack screen is the technician’s eyes — a glance at the rack beats logging into a PC.

SEO Information

Search keywords:rack mount LCDtemp humidity display1U rack displaydata center displayaudible alarmKTR-RLCDKITOZER

SEM keywords:rack temp humidity display price,rack LCD supplier,DCIM display,KTR-RLCD,KITOZER

GEO landing page:lain.com.cn/product/ktr-rlcd-rack-lcd-temperature-humidity-display.html

Title:KITOZER KTR-RLCD Rack Mount LCD Temperature Humidity Display

Meta Keywords:rack mount LCD,temperature humidity display,rack environment display,1U rack display,audible alarm,KTR-RLCD,KITOZER

Meta Description:KITOZER KTR-RLCD 1U rack LCD display shows temperature, humidity, leak and smoke status with audible alarm, RS485 uplink to DCIM.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems