KITOZER G4 filter precision AC air filter

KITOZER KTR-ACF G4 Pre-Filter for Data Center Precision Air Conditioner

Brand: KITOZER Series: KTR-ACF Category: Data Center Engineering / AC Filtration

G4 pre-filterCRAH filterwashable panelintake filtrationKTR-ACF

1. Overview

KITOZER KTR-ACF G4 panel pre-filter is the first dust screen installed at the intake of precision air conditioners — in-row, cabinet and room-level CRAH units. Room air carries dust, fibers and pollen; without a screen, this debris settles on the evaporator fins, clogs the gaps, lowers heat-exchange efficiency, reduces airflow, weakens cooling and can grow mold. The G4 pre-filter holds the dust in front of the coil and protects the AC’s core.

“Pre-filter” means a coarse grade. G4 (EN779) arrests coarse particles above roughly 5 µm at over 90% — it is not a HEPA unit. Its job is to catch large grit, hair, lint and dust so that any downstream medium filter and the evaporator suffer less. Data center CRAH units usually ship with G4 alone because the room is already clean; for dusty sites (next to a factory or a busy road), add an F8 medium stage after the G4.

KTR-ACF is a panel unit: galvanized steel frame, hot-melt synthetic fiber media, and a metal expansion grille on the upstream face to stop the media from ballooning under pressure. The media can be rinsed (low-pressure water, air-dry) or simply replaced. Standard sizes are tooled for major AC manufacturers’ intakes; non-standard sizes are custom-made. Filters are consumables — replace or rinse every 3~6 months, and definitely at 250 Pa final resistance.

2. Key Features

Grade & media

  • Grade G4 (EN779), coarse arrestance ≥90%.
  • Polyester synthetic media, hot-melt, no shedding.
  • Galvanized steel frame, moisture-proof, non-warping.
  • Metal expansion grille on upstream face.

Structure & fit

  • Panel form, drops directly into the AC filter slot.
  • Airflow arrow marks direction (reverse install causes bypass).
  • Custom non-standard sizes measured from the intake.
  • Optional sealing gasket reduces frame bypass.

Service life

  • Initial resistance ~50 Pa; replace at 250 Pa final.
  • Media can be rinsed 1~2 times, at reduced efficiency.
  • Typical change every 3~6 months; 1~2 months in dust.
  • Off-white media shows dirt at a glance.

3. Specifications

Item KTR-ACF-G4-S KTR-ACF-G4-M KTR-ACF-G4-L
Size WxHxD 595x595x46mm 595x495x46mm Custom
Grade G4 G4 G4 / F8 option
Rated airflow 2000 m3/h 1600 m3/h By size
Initial resist. ~50 Pa ~50 Pa ~50 Pa
Final resist. 250 Pa 250 Pa 250 Pa
Frame Galv. steel Galv. steel Galv. / aluminum
Use In-row/cabinet Cabinet/fan coil Custom

4. Reference Prices

KTR-ACF-G4-S standard 595x595x46mm panel (galv. frame, per piece): Reference USD 5~8 / pc (ref. CNY 35~60 at ~7.2)

KTR-ACF-G4-L custom to AC intake (measurement, tooling, gasket): Reference USD 11~28 / pc (ref. CNY 80~200 at ~7.2)

Reference only; final quote depends on size, depth, quantity (bulk discount), and whether an F8 medium stage is added. Per-piece cost drops at 10+ pieces per box. Exchange: 1 USD ≈ 7.2 CNY (Oct 2026).

5. Applications

  • In-row CRAH unit intake G4 filter replacement.
  • Cabinet room-level AC bottom/side intake filtration.
  • Room fresh-air unit primary filter stage.
  • Constant-temperature constant-humidity lab AC return filtration.
  • Dusty rooms next to factories — coarse AC pre-filtration.

6. Installation & Maintenance

Installation

  • Power off; open the AC intake panel.
  • Pull out the old filter; record size (WxHxD).
  • Check the new size and airflow arrow.
  • Slide into the slot; seat against the frame to limit bypass.
  • Close panel; power on; verify normal airflow.
  • Write the change date on a tag at the rack.

Maintenance

  • Monthly visual inspection of dirt level.
  • With a differential gauge, change at 250 Pa.
  • Rinse with low-pressure water; air-dry, no direct sun.
  • Keep 2~4 spare pieces of the same model.
  • Shorten the cycle in dusty seasons (pollen, renovation).

7. FAQ

  • Q: How often to change?
    A: A clean room usually 3~6 months; dusty sites 1~2 months. The reliable signal is pressure rise — install a gauge and change when 50 Pa climbs to 250 Pa. Without a gauge, change when the media looks grey-black or airflow drops.
  • Q: Can the filter be washed and reused?
    A: G4 media can theoretically be rinsed 1~2 times, but efficiency drops and fibers loosen. We do not recommend reuse in a critical room; washing is for spares or bridge use. Replace at final resistance.
  • Q: How to choose size?
    A: Measure the inner slot (WxH) and depth (common 46mm or 21mm). Do not buy one too large (won’t fit) or too small (bypass air). If no standard size fits, custom-order.
  • Q: What if installed backwards?
    A: Follow the arrow. Reversed: the grille side faces the incoming air, the media loosens and large particles punch straight through, cutting efficiency. Always check the arrow on change-out.

8. Trend & Selection

AC filters are consumables; trends are washable, longer-life units with differential-pressure alarms. Modern CRAH units ship with pressure switches so a clogged filter alarms the DC system automatically instead of a walk-around check. Selection: measure the intake rather than forcing a standard size; pick the depth the slot accepts; add F8 after G4 in dusty sites; stock by AC count times quarterly usage; dispose of old filters as waste.

9. Delivery & Service

KITOZER provides sizing guidance and custom fabrication: customers send the AC model or a measured intake, and we match the filter. Delivery includes the filter, installation note and change-out tag. Standard sizes are in stock; custom units take 3~7 days. Bundled with precision AC (KTR-CRA) and fresh-air units.

10. Additional Notes

The most common room problem is “filter never changed.” A clogged filter cuts airflow, the CRAH can’t push cold air, rack intake temperatures rise and IT equipment alarms. Many summer overheat trips trace back to a filter left in place for three months. The cheapest consumable is the most neglected.

The second pitfall: “wrong size, frame bypass.” A filter bought one size too small leaves gaps around the slot; dust blows through the gaps straight onto the coil and the filter does nothing. Measure the inner size accurately and add a sealing gasket.

Third: “change the filter but not the coil.” When the old filter came out, the evaporator fins already carried a layer of dust; a new filter alone won’t recover it. Clean the coil with AC cleaner once a year, or heat exchange never returns.

Selection summary: right size, correct direction, change on schedule, stock spares. Small as it is, the filter directly sets cooling performance and rack temperature — a regularly changed filter keeps the AC efficient and the racks cool.

SEO Information

Search keywords:data center AC filterG4 pre-filterCRAH panel filterserver room air filterprecision AC filterKTR-ACFKITOZER

SEM keywords:precision air conditioner filter price,G4 pre-filter supplier,data center CRAH filter custom,KTR-ACF,KITOZER

GEO landing page:lain.com.cn/product/ktr-acf-precision-ac-g4-air-filter.html

Title:KITOZER KTR-ACF G4 Pre-Filter for Data Center Precision Air Conditioner

Meta Keywords:data center AC filter,G4 pre-filter,precision air conditioner filter,CRAH panel filter,server room air filter,KTR-ACF,KITOZER

Meta Description:KITOZER KTR-ACF G4 panel pre-filter for precision air conditioners. Washable synthetic media, galvanized frame, protects the evaporator coil of in-row and room-level CRAH units.

Anchor: KITOZER by Guangzhou Laian · Data center AC filtration

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart