ToggleKITOZER KTR-LC2 LC-LC Duplex Fiber Patch Cord (OM3/OM4/Single-mode)
Brand: KITOZER Series: KTR-LC2 Category: Data Center Engineering / Structured Cabling
LC-LC duplexOM3/OM4low loss10G readyKTR-LC2

1. Overview
Optical transceivers (article 138) plug into switches with an LC port; an LC-LC duplex patch cord links the module to the patch panel or ODF (article 94). One cord has two fibers (Tx and Rx), both ends LC — the most-used patch cord in a data center, with hundreds to thousands deployed in a mid-size room. KITOZER KTR-LC2 ships in single-mode yellow and multimode aqua (OM3/OM4), lengths from 1 m to 30 m.
By connector: LC-LC (small square, most common at switches/modules), SC-SC (large square, older gear/ODF), LC-SC (hybrid), LC-FC (round, legacy). By fiber: single-mode OS2 (yellow, 9/125 µm, long haul), multimode OM3 (aqua, 50/125 µm, 10G 300 m), OM4 (aqua, 10G 550 m), OM2 (orange, 100M/1G short). By jacket: LSZH low-smoke zero-halogen (data center), PVC (general).
Key specs: insertion loss (≤0.3 dB/connector), return loss (≥30 dB), end-face polish (APC green angle / UPC blue), cable diameter (2.0 mm round / 3.0 mm), pair (duplex). Data-center 10G networks generally use LC-LC OM3 aqua duplex LSZH cords.
2. Key Features
Fiber & performance
- Single-mode OS2: 9/125 µm, yellow jacket.
- Multimode OM3: 50/125 µm, aqua, 10G 300 m.
- Multimode OM4: 10G 550 m.
- Insertion ≤0.2 dB/connector; return ≥50 dB (UPC).
Connector & polish
- LC duplex, ceramic ferrule.
- UPC end-face (blue) for data comms.
- APC (green) for CATV/analog, optional.
- Mating cycles ≥1000.
Jacket & length
- LSZH low-smoke zero-halogen, flame retardant.
- 1/2/3/5/10/15/20/30 m lengths.
- Pull-proof, bend-radius compliant.
- Labeled, same number on both ends.
3. Specifications
| Item | KTR-LC2-SM | KTR-LC2-OM3 | KTR-LC2-OM4 |
|---|---|---|---|
| Fiber | SM OS2 | MM OM3 | MM OM4 |
| Core | 9/125 µm | 50/125 µm | 50/125 µm |
| Jacket | Yellow | Aqua | Aqua |
| Rate/distance | 10G 10 km | 10G 300 m | 10G 550 m |
| Insertion | ≤0.2 dB/connector | ||
| Return loss | ≥50 dB (UPC) / ≥60 dB (APC) | ||
| End face | UPC (blue) std; APC (green) opt. | ||
| Jacket | LSZH | ||
4. Reference Prices
KTR-LC2-OM3 LC-LC duplex (3 m, aqua, LSZH): Reference USD 2~5 each (ref. CNY 15~35 at ~7.2); 5 m ~USD 3~6; 10 m ~USD 4~10
KTR-LC2-SM single-mode LC-LC (3 m, yellow, LSZH): Reference USD 2~4 each (ref. CNY 12~30 at ~7.2); OM4 ~USD 3~7 each (3 m)
Reference only; final quote by fiber type, length, polish (UPC/APC) and quantity. Bulk (hundreds per room) negotiated. Exchange: 1 USD ≈ 7.2 CNY (Oct 2026).
5. Applications
- SFP+ transceiver (article 138) to ODF (article 94) patching.
- Switch-to-server NIC fiber links.
- ODF-to-patch-panel cross-connect.
- In-rack cabling in hot/cold aisles.
- Building fiber termination to equipment.
6. Installation & Maintenance
Installation
- Confirm device port (LC vs SC/FC).
- Pick OM3/OM4/SM by distance; do not mix.
- Remove dust cap; insert LC until it clicks.
- Pair Tx-to-Rx (A-Tx to B-Rx).
- Route and tie; bend radius ≥10× cable.
- Label both ends with same number.
- Measure link loss with a power meter.
Maintenance
- Clean end-face before mating (cleaning pen).
- Recap when not in use.
- Do not sharply bend or step on cords.
- Re-print lost labels.
- Stock common lengths as spares.
7. FAQ
- Q: Can I mix OM3 and OM4?
A: Yes. OM4 is backward-compatible with OM3; on a mixed link, distance is limited by the lower grade (OM3). Do not mix with OM2 — its bandwidth won’t support 10G. - Q: Can single-mode and multimode patch together?
A: No. Core diameters differ (SM 9 µm, MM 50 µm); no light passes. Single-mode modules (LR in article 138) use yellow SM cords; multimode (SR) use aqua OM3. - Q: UPC vs APC?
A: Data comms (switches, SFP+) use UPC blue — slightly convex, low insertion loss. APC green angle is for CATV/PON analog where low return loss matters. Data-center networks use UPC throughout. - Q: Is longer cord better?
A: No. Each connector has insertion loss; longer cords add loss and cable mess. Choose the shortest length that reaches — rack to ODF is usually 3~5 m; don’t run a 20 m cord where 1 m suffices.
8. Trend & Selection
Fiber cabling trends: “OM4/OM5 mainstream, pre-termination.” Early OM2 orange; today 10G+ starts at OM3 aqua, with OM4/OM5 for 40G/100G. Pre-terminated trunk cables (factory-polished reels) are growing in large data centers — on-site crews only plug in. Selection: 10G starts at OM3; high-density uses OM4; long-haul single-mode uses OS2 yellow; standardize on LC; LSZH jacket; UPC polish; right length; bulk labeling.
9. Delivery & Service
KITOZER provides cord selection, custom lengths and end-face testing. Delivery includes cord, dust caps and labels. Bundled with SFP+ transceivers (article 138), ODF (article 94) and fiber patch panels (article 126).
10. Additional Notes
The most common pitfall is “dirty connectors.” Frequent patching in data centers makes dirty end-faces the #1 cause of flaky links. Keep a fiber cleaning pen (~USD 14) and clean the end-face after every insertion.
Second pitfall: “Tx/Rx swapped.” An LC duplex carries Tx and Rx; both ends must be crossed (A-Tx to B-Rx). If the port LED is dark, swap the pair at one end.
Third pitfall: “wrong length bought ad hoc.” On-site crews buy 20 m for a 1 m run, leaving loops of cable behind the rack. Order by actual reach; stock 3/5/10 m bins.
Selection summary: start at OM3, yellow SM / aqua MM, LC connectors, UPC polish, right length, clean end-faces. Cords cost a few RMB each, but thousands of cords are the data center’s veins — right selection, clean ends, clear labels, and the fiber plant stays tidy.
SEO Information
Search keywords:LC-LC patch cordduplex fiber cord10G OM3 cordLC fiber pigtailmultimode jumperKTR-LC2KITOZER
SEM keywords:LC-LC patch cord price,OM3 patch cord supplier,10G multimode fiber jumper,KTR-LC2,KITOZER
GEO landing page:lain.com.cn/product/ktr-lc2-lc-lc-patch-cord.html
Title:KITOZER KTR-LC2 LC-LC Duplex Fiber Patch Cord (OM3/OM4/Single-mode)
Meta Keywords:LC-LC fiber patch cord,duplex fiber jumper,10G OM3 patch cord,LC fiber pigtail,multimode fiber cord,KTR-LC2,KITOZER
Meta Description:KITOZER KTR-LC2 LC-LC duplex fiber patch cords: OS2 single-mode, OM3/OM4 multimode, low insertion loss, paired with SFP+ transceivers (article 138).
Anchor: KITOZER by Guangzhou Laian · LC-LC patch cord
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com