ToggleKITOZER KTR-CON Precision Air Conditioner Air-Cooled Condenser
Brand: KITOZER Series: KTR-CON Category: Data Center Engineering / Precision AC Condenser
air-cooled condenseroutdoor unitV-coiltop dischargeKTR-CON
1. Overview
The outdoor condenser is what moves the heat from the room to the atmosphere. The compressor pushes hot high-pressure refrigerant from the indoor unit to the condenser coil, where axial fans blow outside air across the finned coil and reject the heat; the refrigerant condenses back to liquid and returns indoors. How well the condenser rejects heat decides whether the high-side pressure stays stable and whether the compressor trips on high pressure in summer.
The KITOZER KTR-CON air-cooled condenser uses a V-shaped copper-tube/fin coil, top-discharge axial fans, and is built for rooftops, outdoor pads or wall-side equipment rooms. It comes in 20/40/60 kW matching tiers with 2/4/6 fans, pairing with KTR-EV evaporators and mainstream precision AC indoor units. Coils carry anti-corrosion coating; fans offer three-speed control linked to the indoor unit for head-pressure regulation, with low-noise design.
Selection hinges on matching and location: condensing capacity should exceed the indoor heat rejection by 1.1~1.2×, or summer high-pressure trips will be frequent. The outdoor unit needs good ventilation, no heat recirculation against parapet walls, and at least 1.5 m clearance above for V-type units. Refrigerant piping is limited to ~30 m single-run and ~15 m lift; beyond that add an oil separator and oil-return bends.
2. Key Features
Heat rejection
- V-coil double-sided intake, large area.
- Copper tube + louvered aluminum fins, high k.
- Top discharge sends hot air upward.
- 3-speed fans modulate head pressure.
Durability & range
- Coil anti-corrosion coating for coastal/industrial air.
- IP54 axial fans for outdoor duty.
- Operating ambient -20~+55°C.
- Powder-coated steel housing, UV resistant.
Matching & control
- Pairs with 20/40/60 kW indoor units.
- Fan-speed wiring links to indoor controller.
- Welded or flare refrigerant ports.
- Vibration pads and rain bends available.
3. Specifications
| 项目 | KTR-CON-20 | KTR-CON-40 | KTR-CON-60 |
|---|---|---|---|
| 匹配制冷量 | 20 kW | 40 kW | 60 kW |
| 冷凝器型式 | V型风冷 | V型风冷 | V型风冷 |
| 铜管排数 | 2排 | 2排 | 3排 |
| 风机数量 | 2台 | 4台 | 6台 |
| 风机出风方向 | 顶出风 | 顶出风 | 顶出风 |
| 工作环境温度 | -20~+55℃ | -20~+55℃ | -20~+55℃ |
| 噪声(距10m) | ≤58 dB(A) | ≤62 dB(A) | ≤65 dB(A) |
| 冷媒接口 | Φ16/Φ22 | Φ22/Φ28 | Φ28/Φ35 |
4. Reference Prices
KTR-CON-20 air-cooled condenser (20kW, 2 fans):Reference USD 1,667~3,056 / pc (ref. CNY 12,000~22,000 at ~7.2)
KTR-CON-40 air-cooled condenser (40kW, 4 fans):Reference USD 3,056~5,833 / pc (ref. CNY 22,000~42,000 at ~7.2)
KTR-CON-60 air-cooled condenser (60kW, 6 fans):Reference USD 5,833~10,833 / pc (ref. CNY 42,000~78,000 at ~7.2)
Reference only; final quote depends on capacity, core count, channel count, current rating, battery layers, port count and sensor points. 1-year warranty included; volume pricing available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Outdoor condenser for precision AC indoor units.
- Replacement when original condenser undersized/high-pressure trips.
- New data center outdoor heat rejection.
- Retrofit fixed-speed to modulated fans.
- Lab and archive constant-T/RH AC outdoor units.
6. Deployment & Implementation
Installation
- Check structural load; V-units vibrate.
- Leave service clearance above and sides.
- Keep refrigerant run length/lift within limits.
- Level the unit with vibration pads.
Operations
- Clean fins yearly for oil/dust fouling.
- Listen to fan bearings and motor temp.
- Power off and cover in long winter idle.
- Watch high-side pressure; clean first when it climbs in summer.
7. FAQ
- Q: Frequent high-pressure alarm — is the condenser too small?
A: Slightly higher pressure in hot ambient is normal; but repeated trips and hot supply air mean clean fins first, then verify condensing margin. - Q: How far can the condenser be from the indoor unit?
A: Standard run ≤30 m single way and ≤15 m lift; longer needs larger pipes, an oil separator and oil-return bends, or compressor oil return suffers. - Q: V-type vs top discharge?
A: V-coil takes air from both sides and discharges up, efficient but foot-print large; tight pads may use side-discharge units with clear airflow path. - Q: Can it start at -20°C?
A: Standard units start down to -20°C; colder north sites need low-ambient version (crankcase heater, head-pressure control) or dry cooler with glycol.
8. Trend & Selection
Data-center cooling is evolving from air-cooled only to air-cooled + free cooling and chiller + dry cooler. The outdoor heat-rejection end emphasizes large airflow, low noise, EC fans and smart speed modulation. Key selection: size condensing capacity at 1.1~1.2× indoor heat rejection; verify ventilation and service clearance; keep piping run/lift within limits; when summer pressure climbs, clean fins before upsizing. The condenser sits outdoors in sun and rain yet is the last line that lets the cooling hold through summer.
9. Delivery & Service
KITOZER provides KTR-CON selection and matching: based on indoor capacity, pad dimensions and refrigerant run/lift, we match 20/40/60 units. Vibration pads, connecting copper and insulation can be bundled. Every unit is powered and leak-tested with a report. 1-year warranty; remote or on-site installation guidance (extra).
10. Additional Notes
The common mistake is placing the condenser inside a parapet dead corner. Hot air cannot escape and is re-ingested, raising high-side pressure 0.3~0.5 MPa and tripping in summer. Simulate the wind path before mounting.
Another pitfall is skipping insulation on refrigerant pipes. The suction (thick) pipe must be insulated or it sweats in summer; liquid line too. Keep a continuous oil-return slope toward the compressor.
Selection summary: size at 1.1~1.2× heat rejection; leave ventilation and service clearance; keep run/lift ≤30 m/15 m; insulate the suction line; clean fins yearly; clean before upsizing when pressure climbs. The condenser is the heat-rejection lung — without it, the compressor (heart) suffers.
SEO Information
Search keywords:air-cooled condenserprecision AC outdoor unitV-coil condensertop discharge fandata center coolingKTR-CONKITOZER
SEM keywords:precision AC condenser price,air-cooled outdoor unit,V-coil condenser,high pressure alarm,KTR-CON,KITOZER
GEO landing page:lain.com.cn/product/ktr-con-air-cooled-condenser.html
Title:KITOZER KTR-CON Precision Air Conditioner Air-Cooled Condenser
Meta Keywords:precision air conditioner condenser,air-cooled outdoor unit,V-type coil,KTR-CON,KITOZER
Meta Description:KITOZER KTR-CON air-cooled condenser, V-coil top discharge, matches 20/40/60kW precision AC, anti-corrosion low-noise, efficient heat rejection.
Anchor: KITOZER by Guangzhou Laian · AC condenser
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com