KITOZER
KITOZER

KITOZER metered PDU current display

KITOZER KTR-MPDU Metered Rack PDU with Current Display

Brand: KITOZER Series: KTR-MPDU Category: Power Distribution / Metered PDU

metered PDUcurrent displayC13 C19RS485 remoteKTR-MPDU

KITOZER KTR-MPDU metered rack PDU with digital current display C13 C19 outlets

1. Overview

Racks keep filling with servers, switches and storage, each plugged into an outlet — but what is the total current? A plain PDU has outlets but no metering: overloads go unnoticed until a breaker trips. A metered PDU adds a current/voltage meter showing rack power in real time; higher models add RS485 to push data to the DCIM/environment monitoring, so operators know the load.

The KITOZER KTR-MPDU series comes in 16/32/63 A tiers. Aluminum housing, horizontal 1U or vertical mount; outputs mix C13 (10 A small gear) and C19 (16 A servers/switches) to cover mainstream IT gear. The front LED shows voltage/current/power at 1.0-class accuracy; the 63 A model adds RS485 Modbus-RTU to feed the environment system. Built-in breaker and surge module provide overcurrent and surge protection.

Selection hinges on rated current, outlet mix and comms: first sum full-load rack current (device watts / 220 V) with 1.3× margin to pick 16/32/63; then match C13/C19 counts to devices (servers lean C19, network gear leans C13); pick RS485 only if remote reading is needed. Note: more outlets does not mean more capacity — total current is capped by the input cord and breaker, not by outlet count.

2. Key Features

Metering & display

  • LED real-time voltage/current display.
  • 1.0-class accuracy for visible load.
  • PF / apparent power optional.
  • 63 A model adds RS485 to DCIM.

Distribution & protection

  • Mixed C13/C19 for mainstream gear.
  • Built-in breaker overcurrent protection.
  • Integrated surge protection module.
  • Aluminum housing for heat dissipation.

Mounting & compat

  • 1U horizontal or vertical mount.
  • Standard rack mounting holes.
  • Input cord length custom (1.8~3 m).
  • Color-coded A/B feeds.

3. Specifications

项目 KTR-MPDU-16 KTR-MPDU-32 KTR-MPDU-63
额定电流 16 A 32 A 63 A
输入插头 C20 / 16A工业 32A工业 63A工业
输出插座 C13×8 / C19×2 C13×12 / C19×4 C13×20 / C19×6
电压显示 LED数字 LED数字 LED数字+RS485
电流显示 LED数字 LED数字 LED数字+RS485
计量精度 1.0级 1.0级 1.0级
安装方式 机架1U 机架1U/竖直 机架竖直
保护 过流/防雷 过流/防雷 过流/防雷+分路

4. Reference Prices

KTR-MPDU-16 metered PDU (16A, 8×C13+2×C19):Reference USD 49~97 / pc (ref. CNY 350~700 at ~7.2)

KTR-MPDU-32 metered PDU (32A, 12×C13+4×C19):Reference USD 90~167 / pc (ref. CNY 650~1,200 at ~7.2)

KTR-MPDU-63 metered PDU (63A, 20×C13+6×C19, RS485):Reference USD 208~389 / pc (ref. CNY 1,500~2,800 at ~7.2)

Reference only; final quote depends on capacity, core count, channel count, current rating, battery layers, port count and sensor points. 1-year warranty included; volume pricing available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Rack power metering and monitoring.
  • Network room outlet expansion and current sensing.
  • Remote meter reading and alarms in environment systems.
  • IDC capacity planning and load balancing.
  • Lab and studio equipment power measurement.

6. Deployment & Implementation

Installation

  • Match PDU rating to upstream breaker/cord.
  • Vertical for cable routing, 1U for height saving.
  • Cord gauge by rating (16 A ≥2.5 mm²).
  • Cross-feed A/B dual PDUs for redundancy.

Operations

  • Check displayed current vs actual load monthly.
  • Keep RS485 address unique on the bus.
  • After a trip, find overload before resetting.
  • Replace surge modules at end of life.

7. FAQ

  • Q: Metered vs smart PDU?
    A: Metered PDU measures total current/voltage locally or remotely; smart (switched/outlet-metered) adds per-outlet remote switching and outlet-level metering. If you only need total current, metered PDU is better value.
  • Q: C13 or C19?
    A: C13 (10 A) for small switches/routers; C19 (16 A) for servers and high-power storage. Match the device cord plug.
  • Q: How many servers on a 16 A PDU?
    A: By total current, not outlet count. A dual-power server draws ~2~4 A, so a 16 A PDU with margin carries ~4~6; beyond that go 32 A.
  • Q: How to wire RS485 to DCIM?
    A: Connect A/B (or D+/D-) to the monitoring module’s RS485 port, set 9600 baud and a unique Modbus address, then register points in the DCIM software.

8. Trend & Selection

Rack power is moving from just-on to measurable, remote-controllable and outlet-level switched; metered PDU is the baseline, switched/outlet-metered PDU spreads in IDCs. Key selection: size by rack current ×1.3; match C13/C19 to device plugs; choose RS485 only for remote reading; match upstream breaker and cord gauge; cross-feed A/B. The metered PDU is just a power strip, yet it is the eye into rack power safety and capacity planning.

9. Delivery & Service

KITOZER provides KTR-MPDU selection: by rated current (16/32/63), C13/C19 outlet mix, and RS485 option. Custom cord length and plugs. Factory power-on test of display and comms. 1-year warranty; custom lengths and labeling in volume.

10. Additional Notes

The common mistake is over-provisioning outlets while total current exceeds the rating. Ten C13s look like enough, yet total current is near the 16 A ceiling and one upstream breaker trips the whole rack. Size by total current, not outlet count.

Another pitfall is reversing RS485 A/B. With reversed wires the DCIM reads nothing and the device is wrongly blamed. Check A/B definitions both ends and add a 120 Ω terminator at the bus end.

Selection summary: size by rack current ×1.3 to 16/32/63; match C13/C19 to plugs; pick RS485 for remote reading; match upstream breaker and cord; cross-feed A/B. The metered PDU makes power visible and overloads visible early.

SEO Information

Search keywords:metered PDUrack power distributioncurrent display PDUC13 C19 outletsRS485 monitoringKTR-MPDUKITOZER

SEM keywords:metered PDU price,rack current display power strip,C13 C19 PDU,RS485 smart power,KTR-MPDU,KITOZER

GEO landing page:lain.com.cn/product/ktr-mpdu-metered-rack-pdu.html

Title:KITOZER KTR-MPDU Metered Rack PDU with Current Display

Meta Keywords:metered PDU,rack power distribution unit,current display,C13 C19 outlets,KTR-MPDU,KITOZER

Meta Description:KITOZER KTR-MPDU metered PDU, LED voltage/current display, 16/32/63A, mixed C13/C19, RS485 remote, overcurrent and surge protection.

Anchor: KITOZER by Guangzhou Laian · Metered PDU