Water supply and drainage stations rarely run at a fixed flow rate. Demand swings through the day, peak-hour fire duty spikes the system pressure, and running a fixed-speed pump against a throttled valve wastes energy. The KITOZER pump and VFD control package pairs horizontal end-suction centrifugal pumps with dedicated VFD control cabinets that adjust speed in real time to hold pressure or flow, with PID closed-loop regulation, multi-pump alternation and pump-protection logic built in.

Table of Contents
ToggleWhat the package covers
This reference configuration is for a 11-pump station (2×22 kW, 3×75 kW, 6×55 kW), each pump paired with its own wall-mounted VFD control cabinet. The cabinet supplies the pump motor with variable-frequency power, reads a pressure transducer on the discharge header, and adjusts pump speed to hold a set pressure — starting pumps in sequence and rotating duty so runtime is balanced.
Reference configuration (EXW Guangzhou, USD)
Figures below are market reference prices, EXW Guangzhou, excluding tax and freight. Package reference total: USD 140,278.
| Item | KITOZER Model | Spec | Qty | Unit Price (USD) |
|---|---|---|---|---|
| End-suction pump | KZ-ES-P22 | 22 kW, 120 m³/h @ 35 m, DN125 inlet, inverter-duty motor | 2 | $5,139 |
| End-suction pump | KZ-ES-P75 | 75 kW, 450 m³/h @ 35 m, DN200 inlet, inverter-duty motor | 3 | $11,667 |
| End-suction pump | KZ-ES-P55 | 55 kW, 400 m³/h @ 32 m, DN200 inlet, inverter-duty motor | 6 | $8,889 |
| VFD control cabinet | KZ-VFD-22 | 22 kW pump-duty VFD, PID closed-loop, phase loss / overcurrent / dry-run protection | 2 | $3,000 |
| VFD control cabinet | KZ-VFD-75 | 75 kW pump-duty VFD, PID closed-loop, multi-pump alternation | 3 | $4,389 |
| VFD control cabinet | KZ-VFD-55 | 55 kW pump-duty VFD, PID closed-loop | 6 | $3,750 |
| 11+11 | $140,278 |
Why a dedicated pump VFD cabinet matters
A general-purpose VFD bolted to the wall does not know it is driving a pump. The KITOZER pump-duty cabinet pre-loads pump protection: dry-run detection, dead-head and over-pressure shutdown, rapid-stall restart after a power cut, and a sequential start that staggers motor inrush on a shared feeder. An HMI panel shows running current, output frequency and header pressure, and a Modbus/4G option pushes the same data to the BMS or cloud.
FAQ
Can you supply just the VFD cabinets without the pumps? Yes. We build the control panels to pair with customer-supplied pumps; pump curves and motor nameplate data are required for correct VFD sizing.
What protection functions are standard? Input breaker, output reactor, motor overload, over/under voltage, dry-run, over-pressure and communication-failure shutdown; alarm relay outputs to the BMS.
What is the lead time? Typical lead time after technical confirmation and deposit is 20–30 working days; larger powers may extend this.
Contact KITOZER
KITOZER / Guangzhou Laian Intelligent System Development Co., Ltd.
Tel / WeChat: +86 13922289957 · +86 18520668845
WhatsApp: +86 19068534140
Web: www.gdlain.com · www.lain.com.cn
Address: Chaotian Park, Zhongrun Industrial Zone, No.5 Huashan Road, Shilou, Panyu, Guangzhou, China
Technical reference compiled from industry practice; figures are market reference prices for planning, not a formal quotation.