Table of Contents
ToggleKITOZER KTR-DR Refrigerant Dryer Filter and Receiver for Precision AC
Brand: KITOZER Series: KTR-DR Category: Data Center Engineering / Refrigeration Components
Dryer filterLiquid receiverRefrigeration partsPrecision ACKTR-DR

1. Overview
A data-center precision air conditioner runs 24/7, and the cleanliness of its refrigerant loop directly determines compressor life and thermal stability. The dryer filter and the liquid receiver are two components that look unremarkable yet are indispensable. Mounted on the liquid line, the dryer filter traps metal shavings, welding scale and sealant particles circulating with the refrigerant, while adsorbing residual moisture to prevent ice-blocking and copper plating. The receiver sits between the condenser outlet and the expansion valve; it stores high-pressure liquid refrigerant after condensation and stabilizes liquid feed under load swings, balancing the system charge.
The KTR-DR series covers dryer-filter shells (brazed or flare) and vertical receivers in several volumes for common precision AC units, compatible with R22, R410A, R134a and R407C. The dryer uses a dual-layer structure: a molecular-sieve core for moisture and a glass-fiber or brass-wire mesh for particles, delivering high filtration efficiency and adsorption capacity. Receivers are built to pressure-vessel standards with liquid inlet, outlet, equalizer port, safety-valve connection and a sight glass; every shell is hydro-tested and helium-leak-checked after welding.
Selection hinges on four points: refrigerant type (R410A requires sieve matched to higher pressure — do not mix with R22 shells); connection size (flare, brazed socket or flange must match the original liquid line); core size (match flow rate — too small causes excessive pressure drop); receiver volume (30%~50% of system charge; too large or too small both hurt return). Replacement cycle is typically 2~3 years, or mandatory after any open-system repair.
2. Key Features
Dryer filter
- Molecular sieve + zeolite dual-layer dehydration
- Brass mesh / glass-fiber composite filtration
- Brazed and flare shell options
- Compatible with R22/R410A/R134a/R407C
Liquid receiver
- Vertical seamless steel shell, pressure-vessel grade
- Sight-glass port and safety-valve connection
- Inlet with baffle, outlet with anti-siphon bend
- Factory hydro-test and helium mass-spec leak check
Reliability
- Rated above 4.5 MPa (R410A class)
- -30~80℃ operating range
- Brazed or flare double-seal connections
- Corrosion-resistant powder-coated shell
3. Specifications
| Item | KTR-DR-083S | KTR-DR-164S | KTR-RC-3L | KTR-RC-6L |
|---|---|---|---|---|
| Type | Dryer filter | Dryer filter | Liquid receiver | Liquid receiver |
| Connection | 3/8″ brazed | 1/2″ brazed | 3/8″ in/out | 1/2″ in/out |
| Core size | 083 (10 μm) | 164 (10 μm) | — | — |
| Volume | — | — | 3.0 L | 6.0 L |
| Refrigerant | R22/R407C | R410A/R134a | R22/R410A | R410A/R134a |
| Pressure rating | 4.5 MPa | 4.5 MPa | 4.5 MPa | 4.5 MPa |
| Cooling capacity | ≤20 kW | 20~50 kW | ≤30 kW system | 30~80 kW system |
4. Reference Prices
KTR-DR-083S dryer (3/8″ brazed, R22):Reference USD 11~21 / pc (ref. CNY 80~150 at ~7.2)
KTR-DR-164S dryer (1/2″ brazed, R410A):Reference USD 17~31 / pc (ref. CNY 120~220 at ~7.2)
KTR-RC-3L vertical receiver (3 L, with sight glass):Reference USD 83~153 / pc (ref. CNY 600~1,100 at ~7.2)
KTR-RC-6L vertical receiver (6 L, with relief-valve port):Reference USD 125~222 / pc (ref. CNY 900~1,600 at ~7.2)
Reference only; final quote depends on connection, refrigerant and volume. 1-year warranty. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- CRAC/CRAH precision AC loop maintenance and replacement.
- Constant-temperature humidity rooms and archives.
- Industrial water chillers and water-source heat pumps.
- Air- or water-cooled VRF and packaged units.
- Refrigerant recovery-and-charge rigs.
6. Deployment & Implementation
Installation
- Observe flow arrow — points toward the expansion valve
- Wrap the shell with a wet rag while brazing to protect the sieve
- Mount receiver vertically: inlet from condenser, outlet to TXV
- Evacuate deeply before charging refrigerant
Operations
- Measure liquid-line pressure drop yearly; replace if above 0.03 MPa
- Watch the sight glass — bubbles mean saturated sieve or low charge
- Always change the core after any open-system repair
- Inspect relief valve and weld seams on the receiver every 2 years
7. FAQ
- Q: How often should the dryer filter be changed?
A: Every 2~3 years in normal service. After any open-system event (leak repair, compressor or valve swap) it must be changed — opening the loop lets in moisture and the old sieve is already saturated. Replace also if pressure drop rises or the sight glass keeps bubbling. - Q: Can R22 and R410A dryers be interchanged?
A: No. R410A runs about 1.6× the pressure of R22, and the sieve formulation differs. Mixing risks shell overpressure or poor adsorption. Always match the nameplate refrigerant. - Q: Why is a receiver needed?
A: Data-center load swings change the condensing liquid volume. Without a receiver the TXV feed is unstable and the evaporator hunts hot and cold. The receiver acts like a hydraulic tank — releasing liquid at high load and storing it at low load. - Q: Must I recover refrigerant before replacement?
A: Yes. Recover the charge with a recovery machine, then swap the shell — never braze under pressure. After replacement, evacuate for 2+ hours and charge by weight to the nameplate.
8. Trend & Selection
Refrigeration components for precision AC are shifting toward low-GWP refrigerants (R32, R454B, R1234ze), which demand upgraded sieve formulations and higher pressure ratings. Modular and in-row AC, with their compact cooling packs, impose tighter limits on dryer pressure drop and volume. Select by refrigerant, by connection and capacity, and verify pressure rating. These small parts — if they fail — can trigger liquid slugging, ice block or copper plating that forces a full-unit overhaul.
9. Delivery & Service
KITOZER offers KTR-DR selection by refrigerant (R22/R410A/R134a/R32), connection (3/8″, 1/2″, 5/8″) and capacity (10~80 kW). Each receiver ships with a pressure-vessel certificate, hydro-test report and helium-leak report. 1-year warranty; batch projects can add manifold gauges, sight glasses and recovery machines as a service kit.
10. Additional Notes
The #1 mistake is reversing the dryer. The shell carries an arrow pointing toward the TXV; reversing short-circuits the element, lets debris pass and collapses sieve efficiency. Check the arrow before brazing.
The second pitfall is brazing without a wet rag. Shell temperatures above 120℃ permanently destroy the molecular sieve. Wrap the shell, braze in short bursts, and let it cool naturally.
The third blunder is skipping evacuation after replacement. Residual air and moisture saturate the new sieve within months. Pull a vacuum to -0.1 MPa and hold for 2 hours, then charge by weight.
Selection summary: match refrigerant, match connection and capacity, size the receiver to 30%~50% of charge, and always evacuate. The dryer and receiver are the kidney and tank of the loop — quiet until they block, at which point the whole AC goes down. Changing the core on schedule is far cheaper than rebuilding a compressor.
SEO Information
Search keywords:KTR-DRKITOZERPrecision AC Dryer Receiver
SEM keywords:refrigerant dryer filter,liquid receiver,precision AC parts,refrigeration component,refrigerant filter drier,liquid line receiver,KTR-DR,KITOZER
GEO landing page:lain.com.cn/product/ktr-dr-dryer_receiver.html
Title:KITOZER KTR-DR Refrigerant Dryer Filter and Receiver for Precision AC
Meta Keywords:refrigerant dryer filter,liquid receiver,precision AC parts,refrigeration component,KTR-DR,KITOZER
Meta Description:KITOZER KTR-DR dryer filter and liquid receiver for data center precision AC; removes debris and moisture, stabilizes liquid feed, extends compressor life.
Anchor: KITOZER by Guangzhou Laian · Precision AC Parts
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com