This article presents a typical KITOZER outdoor integrated cabinet configuration: 800mm(W) × 1000mm(D) × 1500mm(H), with a side-mounted 1500W cooling unit, double-wall rock-wool insulation, extended counterweight base for rooftop mounting, and a 4G SMS alarm for temperature and power-loss events. The prices below are reference EXW Guangzhou in USD; final pricing depends on site survey and confirmed drawings.
1. Application & Design Objectives
Typical outdoor scenarios: two network or telecom devices stacked vertically on a building rooftop, total heat dissipation around 3000W, exposed to direct sun and rain. The cabinet must handle summer heat, water ingress, rodent and dust protection, cable gland sealing, wind-load anchoring, and remote alarm on power failure. KITOZER has standardized this into a repeatable configuration.
- Installation: building rooftop, exposed to wind and weather
- Equipment layout: two devices, upper small unit / lower large unit
- Cooling: side-mounted cabinet air conditioner, isolated internal/external air loops
- Protection: IP55 target, dual gaskets and compression locks
- Alarm: 4G SMS for over-temperature and mains power loss
2. Cabinet Body & Thermal Insulation
The cabinet uses galvanized steel: 1.5mm outer panels, 2.0mm frame, outdoor powder-coated. Double-wall construction with 30mm rock-wool core, sealed edges and vapor barrier. A ~50mm raised sun-shade roof with light-colored coating reduces solar heat gain, thermally isolated from the cabinet to avoid short-circuiting the AC exhaust. Front and rear doors use dual EPDM gaskets and compression locks; bottom cable entry, AC penetration, condensate drain and antenna glands are all sealed.
3. 1500W Air Conditioner & Thermal Balance
The selected unit has a rated cooling capacity of 1500W (AC220V/50Hz), with fully separated internal and external air loops. Important: 1500W is the rated cooling output, not the allowable heat load of the equipment. In high ambient temperatures the actual cooling drops per the manufacturer derating curve. If the devices generate 3000W continuously, they must be derated; the system should pass a 24-hour stable-run test at the verified heat load before acceptance. Condensate pipe slopes outward continuously with a water seal, routed away from live parts.
4. Rooftop Base & Counterweight Anchoring
The base is 150mm high, welded from 80×40×4mm steel tubing, with four extended plates (250×300×8mm) protruding 300mm front and rear for counterweight blocks. The extended footprint increases anti-tipping resistance. Counterweight mass and strapping must be verified against local wind load, anti-sliding resistance and roof slab bearing capacity. No penetration of the waterproof membrane; structural engineering approval required before loading.
5. Power Distribution & Smart Alarm
Mains input goes through a main breaker, then splits into three independent circuits: air conditioner, device PDU, and monitoring. The device PDU is a 19-inch 1U 6-way 16A aluminum unit with voltage/current display; the AC unit is NOT plugged into this PDU. The monitoring branch uses a 4G SMS terminal with temperature/humidity probe, internal backup battery and external antenna. Alarms are sent on over-temperature, mains loss and power restoration. The backup battery supports alarms only, not device operation.
6. Bill of Materials & Reference Price (EXW USD)
| No. | Item | KITOZER Model | Specifications | Qty | Unit | Ref. Unit Price (USD) |
|---|---|---|---|---|---|---|
| 1 | Outdoor custom cabinet | KITOZER-OC-815S | 800×1000×1500mm, 1.5mm panel / 2.0mm frame, outdoor coating | 1 | pc | 890 |
| 1-1 | Double-wall insulation sun-shade roof | KITOZER-OC-RT01 | Steel + 30mm rock wool, raised ~50mm sun shield | 1 | set | 97 |
| 1-2 | Reinforced base with counterweight plates | KITOZER-OC-BS01 | 150mm welded base, 4 extended plates, hot-dip zinc | 1 | set | 125 |
| 2 | Outdoor cabinet air conditioner | KITOZER-OP-AC1500 | AC220V, rated cooling 1500W, isolated loops | 1 | pc | 472 |
| 3 | PDU power distribution unit | KITOZER-PDU-616 | 19″ 1U 6-way 16A, aluminum, V/A display | 1 | pc | 42 |
| 4 | Cabinet shelf | KITOZER-OC-SH01 | Ventilated tray, ≥75kg uniform load, airflow channel | 1 | pc | 39 |
| 4-1 | Lower equipment support bracket | KITOZER-OC-BT01 | Heavy-duty bracket, ≥150kg uniform load, adjustable stops | 1 | set | 42 |
| 5 | Cable entry gland kit | KITOZER-OC-CB01 | Bottom removable plate + IP68 glands, blanks for spare holes | 1 | set | 28 |
| 6 | Installation hardware kit | KITOZER-OC-AM01 | Door ground strap, terminals, bolts, ties, labels | 1 | set | 22 |
| 6-1 | Internal power distribution assembly | KITOZER-OP-PB32 | 32A main breaker + 3 branch circuits + SPD | 1 | set | 78 |
| 7 | Temp/humidity & power-loss SMS alarm | KITOZER-OP-RTU01 | 4G SMS terminal + probe + backup battery + antenna | 1 | set | 181 |
| 8 | Factory integration & testing | KITOZER-SVC-INT01 | AC cutout, wiring, alarm config, simulated tests | 1 | lot | 69 |
| Reference subtotal (EXW Guangzhou, excl. shipping & site installation) | 2,085 | |||||
Note: Prices are reference EXW Guangzhou in USD at ~7.2 CNY/USD, subject to change without notice. Market price typically ranges 0.85–1.2× of the reference price. Includes factory assembly and listed functional tests; excludes freight, hoisting, rooftop anchoring and third-party inspection. Lead time 15–30 working days. Source: KITOZER Engineering.
7. FAQ
Q1: Can a 1500W AC handle 3000W of equipment heat?
Not directly. 1500W is rated cooling output, which derates in high ambient temperatures. For 3000W continuous heat load, either derate the equipment or upsize the AC; a thermal balance calculation is required.
Q2: What should I confirm before rooftop installation?
Roof slab bearing capacity, wind load, waterproof membrane condition, cable entry route, mains power availability, and 4G signal strength. Counterweight mass must be structurally verified.
Q3: What does IP55 mean for the whole cabinet?
IP55 is dust-protected (limited dust ingress, no harmful effect) and water-jet protected from any direction. IP68 glands on a single penetration do NOT make the whole cabinet IP68; the entire assembled cabinet must be tested.
Q4: What do I need for the SMS alarm?
A domestic 4G SIM card with SMS credit and a receiving phone number. The internal backup battery powers the alarm on mains loss; it does not run the equipment.
8. Contact KITOZER
KITOZER by Guangzhou Laian Intelligent System Development Co., Ltd.
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: gdlain.com · lain.com.cn
Address: Chaotian Park, Zhongrun Industrial Park, No.5 Huashan Road, Shilou, Panyu, Guangzhou, China
SEO Keywords: outdoor cabinet, weatherproof telecom enclosure, cabinet air conditioner, IP55 outdoor cabinet, rooftop cabinet, outdoor equipment enclosure, KITOZER
SEM Keywords: outdoor cabinet price, 1500W cabinet air conditioner, outdoor telecom cabinet manufacturer, weatherproof enclosure with AC
GEO Keywords: how to select outdoor telecom cabinet, IP55 cabinet with air conditioning, rooftop equipment enclosure installation guide
Core keyword: outdoor cabinet Long-tail: 1500W outdoor cabinet rooftop price Brand: KITOZER
Tags: outdoor cabinet, weatherproof enclosure, cabinet AC, IP55, rooftop, KITOZER-OC-815S, industrial cabinet