Table of Contents
ToggleKITOZER KTR-BAT24 12V 24Ah VRLA AGM Battery
Brand: KITOZER Series: KTR-BAT24 Category: Power Distribution / Battery
12V24AhVRLA AGMmaintenance-free5~8 year lifeKTR-BAT24
1. Overview
Batteries are the last line of defense in a UPS and emergency system — the instant mains fail, the battery takes over to give equipment time to shut down or start the generator. 12V24Ah is one of the most common small sizes, used in 1~3 kVA small UPS, access controllers, fire alarm panels, emergency lighting and environment hosts. VRLA (valve-regulated lead-acid) is leak-proof, maintenance-free and mountable in any orientation.
The KITOZER KTR-BAT24 uses AGM (absorbent glass mat) technology — electrolyte held in the mat, no free liquid, no leaks. Alloy grids suppress gas recombination; float design life is 5~8 years at 25°C. Copper M5 terminals, front or side exit. Low internal resistance ≤12 mΩ for good high-current discharge. Operating -15~50°C, recommended 20~25°C. Capacity rated at 20-hour rate.
Selection: voltage and capacity must match the UPS (12V17Ah cannot replace 12V24Ah — shorter backup); brand and channel matter (cheap units bulge in 2 years); installation space (ventilation and service aisle); and never mix new and old batteries (mismatched internal resistance drags the new cells down). No more than 4 parallel strings, 40 cells in series.
2. Key Features
Battery tech
- AGM glass mat separator
- VRLA sealed, leak-proof
- Maintenance-free, no watering
- Copper M5 terminals
Performance
- 5~8 year float life at 25°C
- Internal resistance ≤12 mΩ
- High-rate discharge
- Self-discharge ≤3%/month
Safety
- Shrouded terminals
- Flame-retardant ABS case
- Mount in any orientation
- Recyclable
3. Specifications
| Item | KTR-BAT24-S1 | KTR-BAT24-S2 | KTR-BAT24-S3 |
|---|---|---|---|
| 额定电压 | 12 V | 12 V | 12 V |
| 额定容量(20HR) | 24 Ah | 24 Ah | 24 Ah |
| 尺寸(长×宽×高) | 166×125×175 mm | 166×125×175 mm | 166×125×175 mm |
| 参考重量 | ≈7.5 kg | ≈7.5 kg | ≈7.5 kg |
| 浮充电压 | 13.5~13.8 V | 13.5~13.8 V | 13.5~13.8 V |
| 均充电压 | 14.4~15.0 V | 14.4~15.0 V | 14.4~15.0 V |
| 设计寿命(25℃) | 5年标准型 | 7~8年长寿命型 | 5~8年前端子型 |
| 适用机型 | 小型UPS/门禁 | 消防/应急照明 | 前端子UPS柜 |
4. Reference Prices
KTR-BAT24-STD 12V24Ah standard (5 yr)::Reference Reference USD 25~39 / pc (ref. CNY 180~280 at ~7.2)
KTR-BAT24-LG 12V24Ah long-life (7~8 yr)::Reference Reference USD 36~53 / pc (ref. CNY 260~380 at ~7.2)
KTR-BAT24-FT 12V24Ah front-terminal (rack)::Reference Reference USD 39~58 / pc (ref. CNY 280~420 at ~7.2)
Inter-cell connector (per piece)::Reference Reference USD 1~2 / pc (ref. CNY 8~15 at ~7.2)
Reference only; priced by life/terminal type. 1-year warranty; freight by weight. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- 1~3 kVA small UPS battery strings.
- Access control and alarm panel backup.
- Fire alarm panel emergency power.
- Emergency lighting and exit signs.
- Environment host and comms backup.
6. Deployment & Implementation
Installation
- Never mix new/old; same brand and batch
- Torque M5 terminals to 2.0 N·m
- ≥10 mm spacing for ventilation
- Insulate rack against short circuits
Operations
- Quarterly check float voltage (spread ≤0.05 V)
- Annual discharge test (30% capacity)
- Keep top clean and dry
- Every 10°C halves life — hold 25°C
7. FAQ
- Q: Can I use 12V17Ah instead?
A: Same voltage but 30% less capacity means shorter backup. OK as a stopgap; not recommended long-term — the UPS may not ride through a brief outage. - Q: How often to replace?
A: 5~8 years float at 25°C. Replace when capacity drops below 80% on a discharge test. Most rooms replace at 5 years. Every 10°C halves life. - Q: What if a cell bulges?
A: Bulging means internal gas pressure is high — leak and rupture risk. Replace immediately. Usually caused by overcharge or high temperature. - Q: Can I hot-swap?
A: With mains present, open the battery breaker first and use insulated tools; replace one cell at a time. A string of 12 cells sits at 144 V — short-circuit arcs are lethal. Only qualified electricians.
8. Trend & Selection
Lead-acid is losing ground to LiFePO4 lithium — 1/3 the size, 1/4 the weight, 10+ year life, maintenance-free. But in small sizes like 12V24Ah, lead-acid still wins on cost and mature recycling. BMS, per-cell monitoring and remote state-of-health reporting are becoming standard. Lithium-UPS all-in-one units cost 2~3× lead-acid.
9. Delivery & Service
KITOZER supplies KTR-BAT24 by life (standard 5 yr / long-life 7~8 yr), terminal type (front/top) and quantity. Each cell ships with leak and capacity test. Manual and safety sheet included. 1-year warranty; string projects can add racks, connectors, battery breakers and monitoring modules.
10. Additional Notes
The #1 mistake is mixing old and new cells. Replacing 2 bad cells in a 12-cell string mismatches internal resistance — old cells overcharge, new cells undercharge, and the whole string dies within six months. Replace the whole string, not single cells.
The second pitfall is no temperature control in the battery room. Life halves every 10°C: 8 years at 25°C becomes 4 at 35°C and 2 at 45°C. Cool the battery room like the IT room.
The third blunder is never load-testing. Batteries float for 5 years and fail silently on the first outage. Do a 30% capacity discharge test annually to confirm they still deliver.
Selection summary: same brand/batch as a whole string, hold 25°C, annual discharge test, replace bulged cells. Batteries are the fuel tank of the UPS — a great UPS head is useless without good batteries.
SEO Information
Search keywords:KTR-BAT24KITOZER12V 24Ah VRLA AGM Battery
SEM keywords:12V24Ah battery,VRLA AGM,lead acid battery,UPS battery,sealed lead acid,KTR-BAT24,KITOZER
GEO landing page:lain.com.cn/product/ktr-bat24-battery_12v24.html
Title:KITOZER KTR-BAT24 12V 24Ah VRLA AGM Battery
Meta Keywords:12V24Ah battery,VRLA AGM,lead acid battery,UPS battery,sealed lead acid,KTR-BAT24,KITOZER
Meta Description:KITOZER KTR-BAT24 12V24Ah VRLA AGM battery, 5~8 year float design life, for small UPS, access control, fire alarm and emergency lighting.
Anchor: KITOZER by Guangzhou Laian · 12V 24Ah VRLA AGM Battery
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com