Table of Contents
ToggleKITOZER KTR-WFS Water Leak Detection & Flow Sensor for Data Center
Brand: KITOZER Series: KTR-WFS Category: Environmental Monitoring / Leak Detection
leak detectionlocating cablespot sensorRS485KTR-WFS

1. Overview
Water leaks are the most common “catastrophic” failure in a data center. A blocked condensate pan, a loose water fitting, a burst humidifier line, or a seepage from the roof — any leak undiscovered for an hour can flood a rack bottom and fry switches and UPS boards. Temperature/humidity sensors only report “air is damp”; to catch the pool under the floor you need a dedicated leak detection system. There are two forms: spot detectors (fixed sensors at known risk points such as under AC units) trigger on contact with water, and locating leak-detection cables run along possible paths — they alarm and tell you how many meters from the controller the leak is.
The KTR-WFS series has three parts: (1) the leak controller — 1U rack or wall mount with LCD and buttons, supporting up to 4 cables and 16 spot detectors; (2) the locating sensing cable — 6 mm OD, four-conductive-polymer, routed around AC units, under water pipes and below the raised floor, with ±1 m location accuracy; and (3) spot flow detectors — mounted in pans, floor drains and other fixed low points, triggering on contact. The controller outputs RS485 (Modbus-RTU) and dry contacts, integrates with EM platforms, and includes local siren/relay plus email/SMS escalation. Cables support both locating (digital) and non-locating (contact) modes; they detect ethylene glycol solution, purified water and slightly conductive liquids, but not strong acids or bases.
Selection: decide coverage — spot detectors under AC units and at pipe joints are cheap; a locating cable is for whole pipe runs or under-floor coverage; choose output — RS485/Modbus for the EM platform, dry contacts + siren for local-only; size the controller — a small room fits one 8-channel unit, a large room networks several; and route the cable on the floor (not suspended), with spot detectors at the lowest pooling points. Cable life is 3~5 years; aged cables drift and cause false alarms, so calibrate yearly with test solution.
2. Key Features
Detection
- Locating sensing cable, ±1 m accuracy
- Spot detectors at fixed risk points
- Four-conductive-polymer sensing cable
- Detects glycol / pure water / light conductive liquids
Controller
- LCD + buttons, 1U rack / wall
- Up to 4 cables + 16 spot detectors
- RS485 Modbus-RTU + dry contacts
- Siren + platform escalation
Installation & compatibility
- 6 mm cable OD, floor-routed
- Spot detectors IP65
- Operating -10~+60°C
- DC12V / 24V supply
3. Specifications
| Item | KTR-WFS-C | KTR-WFS-R | KTR-WFS-S |
|---|---|---|---|
| Type | Leak controller | Locating cable (per m) | Spot flow sensor |
| Detection | Acquire + display | 4-conductor cable | Electrode contacts |
| Max cable | ≤150 m/loop | Cut to length | Single point |
| Location accuracy | ±1 m | ±1 m | n/a |
| Output | RS485 + dry contact | To controller | To controller |
| Ingress | IP30 (in rack) | IP65 (cable) | IP65 |
| Power | DC12V/24V | — | — |
| Operating temp | -10~+60°C | -10~+60°C | -10~+60°C |
4. Reference Prices
KTR-WFS-C 8-zone leak controller (1U):Reference USD 167~306 / pc (ref. CNY 1,200~2,200 at ~7.2)
KTR-WFS-R locating sensing cable:Reference USD 4.9~9 / m (ref. CNY 35~65 at ~7.2)
KTR-WFS-S spot flow sensor:Reference USD 6.3~12 / pc (ref. CNY 45~85 at ~7.2)
Cable end terminator + reference electrode (kit):Reference USD 11~21 / set (ref. CNY 80~150 at ~7.2)
Reference only; cable priced by the meter. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Precision AC condensate/drip monitoring.
- Cable routed around water pipes and humidifiers.
- Under-floor pooling detection.
- Floor drain / drip pan spot monitoring.
- EM-platform-linked valve shutoff alarm.
6. Deployment & Implementation
Installation
- Lay cable on the floor around AC bases and pipes
- Close loops with end terminators
- Place spot detectors at pooling low points (by drains)
- Daisy-chain controller RS485 to the monitoring host
Operations
- Calibrate sensitivity quarterly with test solution
- Check for rodent bites or crushed cable
- On false alarms, inspect for dust or condensation
- Replace cable wholesale every 3~5 years
7. FAQ
- Q: Spot vs locating cable?
A: If you only know a few risk points (under AC, at fittings), spot detectors are cheaper. To cover whole pipe runs or under-floor areas and know where the leak is, use locating cable. Rooms typically combine both: cable around AC, spot detectors at key drains. - Q: What fluids does it detect?
A: Slightly conductive liquids — tap water, condensate, ethylene glycol solution. Pure RO water has poor conductivity and reduced sensitivity; strong acids/bases corrode the cable and are not suitable. - Q: Alarm but no water on site?
A: Often condensation, dust or a crushed short in the cable. Wipe the cable, check deformation; if it still alarms, inspect the reference electrode and end terminator for oxidation. - Q: Can it close the water valve?
A: The controller dry contact drives a relay to shut the motorized inlet valve. Install a motorized valve on the main water inlet so a leak alarm closes it automatically.
8. Trend & Selection
Leak detection is moving from “passive alarm” to “active prevention”: temperature-compensated cables avoid condensation false alarms; controllers plot the leak point on the DCIM room map; motorized valve shutoff becomes standard. As battery rooms and liquid-cooled racks spread, dedicated coolant leak cables (for fluorinated fluids) are a new product line. Select by spot detectors at risk points, locating cable along paths, RS485 to the platform, and linked motorized valves.
9. Delivery & Service
KITOZER supplies KTR-WFS by controller zones (4/8/16), cable length (by meter) and spot detector count. Each unit ships with controller, sensing cable, end terminators, spot detectors and manual. Test report included. 1-year warranty; batch projects can add motorized valves, sirens and EM platform software.
10. Additional Notes
The #1 mistake is suspending or wall-mounting the cable. Water flows downhill; a cable hanging on a wall or on a tray will miss water pooling below it. Lay it on the floor, along wall bases, and loop around the AC base.
The second pitfall is omitting end terminators. A sensing cable is a closed loop; both ends connect to the controller and the far end gets a terminator. If a segment is left open, the controller reads an invalid resistance and faults out. After routing, read the loop resistance to confirm continuity.
The third blunder is clearing the alarm without fixing the source. Wiping up water and resetting leaves the root cause in place — it leaks again. Correct flow: alarm → close valve → locate → repair (pipe/pan/AC) → dry-test → reset.
Selection summary: spot detectors guard risk points, locating cable follows paths, lay it on the floor, link a motorized valve, calibrate yearly. Leak detection is the last water barrier of the room — every minute earlier saves a rack.
SEO Information
Search keywords:KTR-WFSKITOZERWater Leak Detection & Flow Sensor
SEM keywords:water leak detection,leak sensor,leak detection cable,data center leak monitoring,locating leak,KTR-WFS,KITOZER
GEO landing page:lain.com.cn/product/ktr-water_flow_sensor.html
Title:KITOZER KTR-WFS Water Leak Detection & Flow Sensor for Data Center
Meta Keywords:water leak detection,leak sensor,leak detection cable,data center leak monitoring,locating leak,KTR-WFS,KITOZER
Meta Description:KITOZER KTR-WFS water leak detection, locating sensing cable + spot sensors, RS485/dry contact, for precision AC drip monitoring.
Anchor: KITOZER by Guangzhou Laian · Water Leak Detection & Flow Sensor
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com