KITOZER liquid receiver accumulator tank

KITOZER KTR-LR Liquid Receiver for Precision AC in Data Center

Brand: KITOZER Series: KTR-LR Category: Data Center Engineering / Precision AC Refrigeration

liquid receiverrefrigerant tanksight glassshutoff valveKTR-LR

1. Overview

The refrigeration loop of a precision air conditioner is a closed refrigerant circuit: the compressor squeezes low-pressure cool gas into high-pressure hot gas, the condenser rejects heat and condenses it to liquid, and the expansion valve throttles it down so it evaporates in the evaporator and absorbs heat. The refrigerant charge must be just right — too much drives high-side pressure up and risks liquid slugging the compressor; too little starves the expansion valve and the room stops cooling. Real duty is dynamic: full load in summer, part load in winter, varying fan speeds and outdoor temperatures change how much refrigerant resides in each component. A liquid receiver is a steel tank installed between the condenser outlet and the expansion valve — it swallows excess liquid refrigerant so the expansion valve always has a stable liquid feed, and it stores refrigerant during service so you do not have to pump the whole system out.

The KTR-LR series is built from seamless steel tube or welded plate, vertical orientation, in volumes from 3 L to 50 L covering 5~120 kW precision units. The top has a vapor equalization port to the condenser outlet; the bottom has a liquid port to the drier/expansion valve; a side service shutoff valve allows pump-down. Weld or flange connections are offered; a sight glass, high-pressure switch port and safety valve port are optional. Each vessel is hydro-tested at 1.5× working pressure, powder-coated for corrosion, rated for 4.5 MPa working pressure (suitable for R410A/R32).

Selection: size the volume at roughly one-third to one-half of total system charge — large enough to avoid flooding the condenser outlet at full load, small enough to hold excess at part load; confirm the refrigerant (R22/R410A/R32/R134a) because wall thickness and port sizes differ; install close to the condenser outlet before the expansion valve with short piping; and mount vertically with top-inlet/bottom-outlet — reversed plumbing defeats the receiver.

2. Key Features

Vessel

  • Vertical steel tank, seamless or welded
  • 3 L ~ 50 L volume range
  • 4.5 MPa working, 6.75 MPa hydro test
  • Powder-coated for data-center environments

Ports

  • Top vapor port to condenser
  • Bottom liquid port to drier
  • Side service shutoff valve
  • Optional sight glass / safety valve / HP switch

Compatibility

  • R22 / R410A / R32 / R134a
  • Weld or flange connections
  • Vertical mount, top-in/bottom-out
  • Mounting bracket + vibration pad included

3. Specifications

Item KTR-LR-3 KTR-LR-10 KTR-LR-20 KTR-LR-50
Volume 3 L 10 L 20 L 50 L
Cooling capacity 5~15 kW 15~40 kW 40~80 kW 80~120 kW
Working pressure 4.5 MPa 4.5 MPa 4.5 MPa 4.5 MPa
Hydro test 6.75 MPa 6.75 MPa 6.75 MPa 6.75 MPa
Connection Weld Φ12 Weld Φ16 Weld Φ22 Flange DN25
Size H×D 320×140 mm 480×200 mm 650×260 mm 900×350 mm
Charge ref. 1.5~2.5 kg 4~8 kg 8~16 kg 16~30 kg
Mount Bracket Bracket Bracket Floor stand

4. Reference Prices

KTR-LR-3 (3 L) small receiver:Reference USD 39~63 / pc (ref. CNY 280~450 at ~7.2)

KTR-LR-10 (10 L) medium receiver:Reference USD 76~125 / pc (ref. CNY 550~900 at ~7.2)

KTR-LR-20 (20 L) large receiver:Reference USD 125~208 / pc (ref. CNY 900~1,500 at ~7.2)

KTR-LR-50 (50 L) floor-standing:Reference USD 250~389 / pc (ref. CNY 1,800~2,800 at ~7.2)

Sight glass / safety valve / shutoff kit:Reference USD 17~49 / set (ref. CNY 120~350 at ~7.2)

Reference only; 1-year warranty. Hydro test report included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Split precision AC indoor/outdoor refrigerant storage.
  • Glycol/water system expansion tank complement.
  • VRF multi-split system refrigerant balancing.
  • Cold storage and constant-temp/humidity units.
  • Temporary refrigerant recovery during service.

6. Deployment & Implementation

Installation

  • Mount vertically, vapor port on top, liquid port below
  • Place near condenser outlet, short line to expansion valve
  • Add flexible vibration joints on both ports
  • Anchor bracket for full-liquid weight

Operations

  • Quarterly inspect sight glass for bubbles
  • Check tank for rust, frost or oil stains
  • Pump down and close valves before opening the tank
  • Calibrate safety valve yearly

7. FAQ

  • Q: Receiver vs accumulator?
    A: A liquid receiver sits on the high side after the condenser and stores liquid; an accumulator sits on the low side before the compressor and prevents liquid slugging. They are not interchangeable.
  • Q: Are bubbles in the sight glass normal?
    A: At steady full load the sight glass should be clear. Persistent bubbles mean low charge or a blocked drier — find the leak and top up. A few bubbles right after startup are normal and should disappear.
  • Q: What if the receiver is plumbed backwards?
    A: If liquid comes in the top and vapor out the bottom, the tank loses buffering — the expansion valve feed becomes unstable and cooling comes and goes. Always top-in/bottom-out.
  • Q: Does the receiver need insulation?
    A: No — it carries warm high-pressure liquid on the high side. In cold outdoor installations, add a weather cover to prevent over-condensation.

8. Trend & Selection

Precision AC is trending toward high efficiency and lower charge: inverter compressors with electronic expansion valves meter the charge precisely, and receivers are shrinking. In large VRF and room systems the receiver remains an essential buffer. Newer units integrate level sensors and EEV feedback to monitor charge in real time. Select by capacity, confirm the refrigerant, mount vertically top-in/bottom-out, and keep it near the condenser.

9. Delivery & Service

KITOZER supplies KTR-LR by cooling capacity (5~120 kW), refrigerant type (R22/R410A/R32/R134a) and connection (weld/flange). Each unit ships with tank, bracket, shutoff valve and manual, plus hydro test report. 1-year warranty; batch projects can add driers, sight glasses and safety valves.

10. Additional Notes

The #1 mistake is over-sizing. Engineers think a bigger tank is safer, but an oversized receiver drowns the liquid outlet at startup, starves the evaporator, and the room takes forever to cool. It also requires more refrigerant and raises cost. Size at 1/3~1/2 of total charge.

The second pitfall is welding the tank without shutoff valves. Without valves you must recover the entire charge every time you service the drier or expansion valve. Install shutoff valves on both ports so service is a quick close-and-open.

The third blunder is undersized brackets. A charged receiver weighs several times its empty weight (steel shell + liquid + oil). Brackets sized for the empty tank crack after years of vibration. Design for full-liquid weight and add vibration pads.

Selection summary: size by capacity, confirm the refrigerant, mount vertically, fit shutoff valves, and bracket for full weight. The receiver is the pantry of the refrigeration loop.

SEO Information

Search keywords:KTR-LRKITOZERLiquid Receiver for Precision AC

SEM keywords:liquid receiver,refrigerant receiver,precision AC refrigeration,refrigerant tank,KTR-LR,KITOZER

GEO landing page:lain.com.cn/product/ktr-liquid_receiver.html

Title:KITOZER KTR-LR Liquid Receiver for Precision AC in Data Center

Meta Keywords:liquid receiver,refrigerant receiver,precision AC refrigeration,refrigerant tank,KTR-LR,KITOZER

Meta Description:KITOZER KTR-LR liquid receiver for precision AC, vertical steel tank with sight glass and shutoff valves, stabilizes refrigerant charge for 5~120kW units.

Anchor: KITOZER by Guangzhou Laian · Liquid Receiver for Precision AC

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart