KITOZER KTR-THERM Thermal Dual-Spectrum Camera for Data Center

Brand: KITOZER Series: KTR-THERM Category: System Integration / Video Surveillance

thermal imagingdual-spectrumtemp alarmhot spotKTR-THERM

KITOZER KTR-THERM Thermal Dual-Spectrum Camera

1. Overview

Most electrical fires in data centers start as a single overheating connection: a loose bolt in the distribution cabinet, a corroded battery terminal, a bulging UPS capacitor, or a high-resistance cable lug. Before smoke or flame appears, that point has often already reached 80°C, 100°C or more — but traditional temperature/humidity sensors only measure air. A thermal camera reads infrared radiation from surfaces and renders a pseudo-color heat map. Without contact or wired probes, one camera monitors every surface in an entire distribution cabinet or battery room, and any abnormal hotspot lights up on the image.

The KTR-THERM pairs a thermal core (384×288 or 640×512) with a visible-light camera (2~4 MP). Thermal range is -20°C to +550°C, accuracy ±2°C or ±2%. The two channels are overlaid picture-in-picture, so you see both “where it is hot” and “what it is.” You draw measurement boxes on the heat map (one per breaker, per battery terminal), set thresholds, and the camera alarms on threshold exceedance via local siren, ONVIF/RTSP to the VMS, or dry contacts. A built-in web UI lets you view the heat map, set regions and review temperature history without specialist software.

Selection: confirm range — -20~+150°C covers most electrical gear; +550°C is for furnaces or high-power resistors; choose resolution — 384×288 for close-up (3~5 m) cabinet views, 640×512 for long range or wide areas; pick lens by distance — wide (25 mm) for a whole wall, telephoto (50 mm+) for a single lug; and use PoE for simplest wiring, or choose the IO model for dry-contact linkage.

2. Key Features

Thermal performance

  • 384×288 / 640×512 detector
  • -20~+550°C range
  • ±2°C or ±2% accuracy
  • White-hot / black-hot / iron / rainbow palettes

Visible light & analytics

  • 2~4 MP visible channel
  • Picture-in-picture dual overlay
  • Multi-region boxes + threshold alarm
  • Temperature trend history

Interfaces

  • ONVIF / RTSP / GB28181
  • PoE or DC12V
  • 2-in / 2-out dry contacts
  • Wall / pole / ceiling mount

3. Specifications

Item KTR-THERM-336 KTR-THERM-652
Thermal resolution 384×288 640×512
Visible resolution 2 MP (1080P) 4 MP
Temp range -20~+150°C -20~+550°C
Accuracy ±2°C or ±2% ±2°C or ±2%
Thermal lens 25/35 mm 25/50 mm
Visible lens 4 mm fixed 2.8~12 mm motorized
Video H.265, ONVIF/RTSP H.265, ONVIF/RTSP/GB28181
Power PoE / DC12V PoE+ / DC12V
Ingress IP66 IP66

4. Reference Prices

KTR-THERM-336 (384×288) bullet:Reference USD 625~903 / pc (ref. CNY 4,500~6,500 at ~7.2)

KTR-THERM-652 (640×512) bullet:Reference USD 1,181~1,667 / pc (ref. CNY 8,500~12,000 at ~7.2)

Wall/ceiling bracket:Reference USD 11~21 / set (ref. CNY 80~150 at ~7.2)

Install & commissioning (per point):Reference USD 28~56 / point (ref. CNY 200~400 at ~7.2)

Reference only; 1-year warranty. Thermal core is the key component. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Distribution cabinet / row-level PDU connection monitoring.
  • Battery room terminal temperature patrol.
  • UPS internal thermal visualization.
  • Cold/hot aisle differential monitoring.
  • Cable tray / underfloor hot-spot early warning.

6. Deployment & Implementation

Installation

  • Face the target surface at 3~5 m
  • No glass between camera and target (glass blocks IR)
  • Avoid reflective surfaces and background heat sources
  • Keep PoE runs under 100 m

Operations

  • Review heat maps weekly and build a temperature baseline
  • Set threshold 10~15°C above baseline
  • Keep lens clean; dust degrades accuracy
  • Calibrate with a blackbody source quarterly

7. FAQ

  • Q: Can thermal see through cabinet doors?
    A: No. IR only reads surfaces; a closed metal or glass door blocks it. Either mount the camera inside the open cabinet, or fit a germanium IR window in the door.
  • Q: Is ±2°C accurate enough?
    A: Yes for early warning. We do not need 0.1°C precision — we need to notice “this lug is 20°C hotter than its neighbor.” Thermal imaging is about spotting differential anomalies, not metrology.
  • Q: Do I need both channels?
    A: Recommended. A pure thermal image has no labels or context; on alarm you cannot tell which cabinet or lug. Dual-spectrum picture-in-picture pinpoints the location fast.
  • Q: Will it integrate with my VMS?
    A: ONVIF/RTSP works with most VMS for video, but temperature values need SDK or Modbus integration. Basic VMS shows video but not numeric temperature.

8. Trend & Selection

Thermal imaging is moving from military/industrial to mainstream surveillance: detector costs have dropped from tens of thousands to a few thousand yuan, and dual-spectrum cameras are entering data-center power monitoring. AI auto-recognizes breakers, busbars and terminals and auto-labels temperatures. Future systems will link thermal alarms to DCIM topology, highlighting the overheating node in red. Select by resolution (384 for close, 640 for far), lens by distance, and PoE for simple wiring.

9. Delivery & Service

KITOZER supplies KTR-THERM by resolution (384/640), lens focal length and temperature range. Each unit ships with camera, bracket, power supply (if non-PoE) and manual, plus calibration report. 1-year warranty; batch projects can add VMS integration, SDK development and on-site commissioning.

10. Additional Notes

The #1 mistake is aiming through a glass cabinet door. Ordinary glass blocks IR, so the camera reads the glass surface, not the busbar inside. Either install with the door open or fit a germanium IR window — otherwise the install is wasted.

The second pitfall is setting the threshold too high. Some engineers set 150°C so “it alarms only when it is on fire.” A lug at 90°C is already failing; by 150°C it may be smoking. Run a week to establish a baseline, then alarm at baseline +10~15°C.

The third blunder is ignoring trends. Thermal value is in differential change — a lug that rises 20°C from yesterday is abnormal even if the absolute value is low. Record temperature history and compare trends, not just absolute numbers.

Selection summary: 384 for close-up, 640 for long range, lens by distance, open the door or fit an IR window, threshold from baseline, and watch trends. The thermal camera is the early-warning eye for electrical fire prevention.

SEO Information

Search keywords:KTR-THERMKITOZERThermal Dual-Spectrum Camera

SEM keywords:thermal camera,dual-spectrum,temperature monitoring,electrical hot spot,data center thermal,KTR-THERM,KITOZER

GEO landing page:lain.com.cn/product/ktr-thermal_camera.html

Title:KITOZER KTR-THERM Thermal Dual-Spectrum Camera for Data Center

Meta Keywords:thermal camera,dual-spectrum,temperature monitoring,electrical hot spot,data center thermal,KTR-THERM,KITOZER

Meta Description:KITOZER KTR-THERM thermal + visible light dual-spectrum camera, temperature alarm, for power distribution and battery room hot-spot monitoring.

Anchor: KITOZER by Guangzhou Laian · Thermal Dual-Spectrum Camera

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart