KITOZER
KITOZER

KITOZER 12V 12Ah VRLA battery

KITOZER KTR-BAT12 12V12Ah Small Capacity Battery

Brand: KITOZER Series: KTR-BAT12 Category: Power Distribution / Battery

12V12AhVRLAmaintenance-freeUPS backupKTR-BAT12

1. Overview

Not every backup power application needs a hundred-Ah string. Many “small but never-off” loads in a data center need backup: access controllers, EM monitoring hosts, small switches, mini UPS units, fire panels and roller-door controls. These loads draw tens to a few hundred watts, but they are the first things that must survive a power outage — the door must unlock, the recorder must keep writing, the alarm must reach the platform. A 100Ah string is overkill and bulky here; a 12V12Ah cell is just right: the size of a dictionary, about 3.8 kg, fits in a rack or wall box, and 30 minutes to 2 hours of runtime is plenty.

The KTR-BAT12 is a 12V12Ah valve-regulated sealed lead-acid (VRLA) battery using AGM (absorbent glass mat) technology. Electrolyte is absorbed in the mat, so it will not spill and it can be mounted in any orientation except inverted. Internal gas recombination means no venting under normal use — no watering, no specific-gravity checks, just float charging. Float voltage is 13.5~13.8V at 25°C; equalize charge is 14.4~15.0V. Design life is 5~8 years on float at 25°C (halving for every 10°C rise). Terminals are F2 quick-connect (6.3 mm tab) or M5 threaded stud.

Selection: confirm voltage — most small UPS and CCTV systems are 12V (one cell); 24V needs two in series; size the capacity — 12Ah gives 30 min to 2 h for small loads, go to 24Ah/38Ah for longer runtime; match the terminal (F2 tab vs M5 stud) to the cable lug; and remember batteries are classified hazardous waste (lead + acid) — recycle properly, never put in household trash.

2. Key Features

Performance

  • 12V rated, 12Ah (20-hour rate)
  • AGM VRLA sealed, maintenance-free
  • 5~8 year design life (25°C float)
  • Self-discharge ≤3%/month at 25°C

Electrical

  • Float 13.5~13.8V (25°C)
  • Equalize 14.4~15.0V
  • Max discharge 180A (5 s)
  • Operating -15~+50°C

Construction

  • F2 (6.3 mm) or M5 stud
  • Flame-retardant ABS, UL94 V-0
  • Mount any orientation except inverted
  • Small UPS / access / CCTV ready

3. Specifications

Item KTR-BAT12-12 KTR-BAT12-24 KTR-BAT12-38
Voltage 12V 12V 12V
Capacity 12Ah 24Ah 38Ah
Size L×W×H 151×98×95 mm 166×125×125 mm 197×165×175 mm
Weight ~3.8 kg ~7.5 kg ~12.5 kg
Terminal F2/M5 M5 stud M6 stud
Float V 13.5~13.8V 13.5~13.8V 13.5~13.8V
Life (25°C) 5~8 yr 5~8 yr 5~8 yr
Use Access/CCTV/mini UPS Small UPS/alarm Mid UPS/fire panel

4. Reference Prices

KTR-BAT12-12 (12V12Ah) standard:Reference USD 9~13 / pc (ref. CNY 65~95 at ~7.2)

KTR-BAT12-24 (12V24Ah):Reference USD 18~26 / pc (ref. CNY 130~190 at ~7.2)

KTR-BAT12-38 (12V38Ah):Reference USD 31~44 / pc (ref. CNY 220~320 at ~7.2)

Cable + lug kit:Reference USD 1.4~3.5 / set (ref. CNY 10~25 at ~7.2)

Reference only; 1-year warranty. Batteries are hazardous waste — recycle properly. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Mini UPS backup (1~3 kVA).
  • Access control / electric lock backup.
  • NVR / switch hold-up power.
  • Fire alarm panel standby.
  • Emergency lighting, roller-door controls.

6. Deployment & Implementation

Installation

  • Upright mount; never invert or lay flat long-term
  • Series strings must be same model and batch
  • Torque terminals to reduce contact heat
  • Keep away from heat and direct sun; 25°C ideal

Operations

  • Measure terminal voltage quarterly; replace laggards
  • Top up monthly for long-idle batteries
  • Replace immediately on bulge or leak
  • Recycle spent batteries through licensed vendors

7. FAQ

  • Q: How long will a 12V12Ah last?
    A: Depends on load. 12V×12Ah=144 Wh, usable ~80% = 115 Wh. A 30 W NVR runs ~4 hours; a 100 W access controller ~1 hour. Higher wattage = shorter runtime.
  • Q: Do I charge a new battery before install?
    A: It ships at ~80% state of charge; the UPS float will top it up. If stored over 3 months, charge to 13.8 V first to avoid low first-cycle capacity.
  • Q: How do I dispose of old batteries?
    A: Lead-acid contains lead and sulfuric acid — hazardous waste. Return to the dealer or a licensed recycler. Do not put in household trash.
  • Q: Can I mix old and new batteries?
    A: No. Different internal resistances cause the old cell to over-charge/over-discharge and fail early. Strings must be same model, batch and age — replace the whole string.

8. Trend & Selection

Small backup batteries are shifting from VRLA to lithium: a 12V LiFePO4 pack is 1/3 the size, 1/4 the weight and 2000+ cycles. Despite 2~3× upfront cost, total cost of ownership is lower. In space-constrained racks and wall boxes, lithium is taking over. VRLA remains mainstream in low-frequency applications like access control and CCTV thanks to low price and mature supply. Select by load wattage and target runtime, match terminals, keep 25°C ambient, and never mix ages.

9. Delivery & Service

KITOZER supplies KTR-BAT12 by capacity (12/24/38Ah) and terminal (F2/M5/M6). Each unit ships with battery, interconnect cable, manual and test report. 1-year warranty; batch projects can add battery cabinets, chargers and monitoring modules.

10. Additional Notes

The #1 mistake is installing batteries in a hot location. Lead-acid life halves for every 10°C above 25°C. Mounting next to a UPS heatsink or in a sealed summer box at 40~50°C bulges cells in 1~2 years. Place them in a cool, ventilated spot away from heat sources.

The second pitfall is mixing batches in series. Access systems often need 24V (two 12V in series); crews grab two cells from different stock. Mismatched resistances unbalance charging and the weaker cell dies first. Series strings must be same model, same batch, bought and commissioned together.

The third blunder is never checking float voltage. Quarterly voltage checks reveal laggard cells before they drag the whole string down. Without checks, a blackout reveals a string exhausted by one bad cell while the others still have capacity unused.

Selection summary: size by load and runtime, keep it cool, match the batch, measure quarterly, and recycle. The 12V12Ah cell is the workhorse that keeps doors open and cameras recording.

SEO Information

Search keywords:KTR-BAT12KITOZER12V12Ah Small Capacity Battery

SEM keywords:battery,12V12Ah,VRLA,small UPS backup,lead acid battery,KTR-BAT12,KITOZER

GEO landing page:lain.com.cn/product/ktr-battery_12v12ah.html

Title:KITOZER KTR-BAT12 12V12Ah Small Capacity Battery

Meta Keywords:battery,12V12Ah,VRLA,small UPS backup,lead acid battery,KTR-BAT12,KITOZER

Meta Description:KITOZER KTR-BAT12 12V12Ah VRLA valve-regulated lead-acid battery, maintenance-free, for small UPS, access control and CCTV backup, 5~8 year design life.

Anchor: KITOZER by Guangzhou Laian · 12V12Ah Battery

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart