Brand: KITOZER Series: KTR-BAT200 Category: Power Distribution / UPS Battery
12V 200AhVRLAAGMfront terminalKTR-BAT200
1. Overview
The UPS itself stores no energy; the battery string does. When mains drops, the battery bank feeds the inverter, bridging to the diesel generator (usually 5~15 min) or riding through brief outages. Capacity determines runtime: a 10 kVA UPS at ~8 kW needs about 40~50 Ah for 30 minutes, depending on inverter efficiency and end-of-discharge voltage. 12V200Ah is the workhorse for cell sites, small/medium UPS and outdoor integrated power: 12 V nominal, 200 Ah (C20), four in series for 48 V telecom strings or sixteen/thirty-two for 192/384 V UPS buses. The KTR-BAT200 is a valve-regulated lead-acid (VRLA) battery with AGM (absorbent glass mat) starved-electrolyte design — acid held in the mat, no spilling, no watering, mountable in any orientation except long-term inversion. Float design life 12~15 years at 25°C; front terminals for dense cabinet rows.
KTR-BAT200 key data: 12 V nominal, 200 Ah (C20, 2.25 V/cell at 25°C), 522×240×218 mm (L×W×H), 224 mm over terminals, ~65 kg. M8 copper front terminals. Positive plate pasted lead-calcium alloy, negative pasted/tubular, AGM separator, ABS flame-retardant case. Float voltage 2.25~2.27 V/cell, equalize 2.30~2.35 V/cell, end-discharge 1.80 V/cell. Self-discharge ≤3%/month at 25°C, operating -15~+50°C (best 20~25°C). Order codes: KTR-BAT200-FT front terminal (battery cabinets) and KTR-BAT200-TM top terminal (traditional racks).
Selection: series count by UPS bus — 16 strings for 192 V, 32 for 384 V; capacity by runtime (10 kVA at 30 min ≈ one 200 Ah string or two 100 Ah in parallel); load the rack — ~65 kg/cell, 32 cells ≈ 2080 kg, so rack structure must be reinforced; and temperature — every 10°C above 30°C halves life, so the battery room must be air-conditioned to 25°C.
2. Key Features
Type
- VRLA sealed lead-acid
- AGM starved electrolyte, no spill
- Pb-Ca grid, low self-discharge
- ABS flame-retardant case
Electrical
- 12 V 200 Ah (C20)
- Float 2.25~2.27 V/cell
- Equalize 2.30~2.35 V/cell
- End 1.80 V/cell
Mechanical & Environment
- M8 front terminals
- 522×240×218 mm
- ~65 kg
- -15~+50°C operating
3. Specifications
| Item | KTR-BAT100 | KTR-BAT200 | KTR-BAT12-200 |
|---|---|---|---|
| Voltage | 12 V | 12 V | 12 V |
| Capacity (C20) | 100 Ah | 200 Ah | 200 Ah |
| Dimensions | 330×172×214 | 522×240×218 | 522×240×218 |
| Weight | ~30 kg | ~65 kg | ~65 kg |
| Terminal | Front M8 | Front M8 | Top M8 |
| Float V | 2.25 V/cell | 2.25 V/cell | 2.25 V/cell |
| Design life | 10~12 yr | 12~15 yr | 12~15 yr |
| Use | Small UPS | site/large UPS | traditional racks |
4. Reference Prices
KTR-BAT100 12V100Ah front terminal:Reference USD 94~128 / pc (ref. CNY 680~920 at ~7.2)
KTR-BAT200 12V200Ah front terminal:Reference USD 178~233 / pc (ref. CNY 1280~1680 at ~7.2)
KTR-BAT12-200 12V200Ah top terminal:Reference USD 174~225 / pc (ref. CNY 1250~1620 at ~7.2)
Copper link bars + bolts:Reference USD 3.5~6.3 / set (ref. CNY 25~45 at ~7.2)
Reference only; 3-year warranty. Cabinets and install not included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Small/medium UPS DC strings.
- 48 V telecom strings (4×12 V in series).
- Outdoor integrated power backup.
- Data center 15~30 min UPS ride-through.
- EPS emergency power backup.
6. Deployment & Implementation
Installation
- Rack load ≥600 kg/shelf
- Leave terminal wiring clearance
- Series with copper bars, torque M8 ~12 N·m
- Red positive / blue negative leads
Environment
- Battery room 20~25°C
- Ventilate, no H₂ buildup
- Avoid direct sunlight
- Avoid heat and corrosive gas
Operations
- Quarterly measure per-cell float voltage
- Annually discharge-test capacity
- Coat terminals with petroleum jelly
- Plan replacement after 5 years
7. FAQ
- Q: How long will a 12V200Ah last?
A: Rough math: 10 kW load, 0.9 inverter efficiency, 192 V bus → ~58 A. A 200 Ah battery at 0.25C delivers ~160 Ah → ~2.7 h. Real UPS at 8 kW gets ~30 min; check the vendor’s discharge curve. - Q: How long do batteries last?
A: Design life 12~15 yr at 25°C float. Real rooms run 30°C+ → expect 8~10 yr. Capacity fades after 5 yr; annual capacity test below 80% means plan replacement. - Q: Is a swollen battery safe?
A: No — swelling indicates overcharge or internal shorting. Replace immediately and check the charger float voltage. Never mix one new cell into an old string; mismatched internal resistance drags down both. - Q: Why air-condition the battery room?
A: Lead-acid life is temperature-sensitive: every 10°C above 25°C halves life. A 35°C room turns a 12-year design into 6. Room AC at 25°C is the highest-return maintenance spend.
8. Trend & Selection
Data-center battery paths are diverging: VRLA remains the workhorse for small/medium rooms; LFP lithium is penetrating large cloud data centers — half the volume and weight, 3~5× cycle life, but 2~3× the unit cost and requiring a dedicated BMS cabinet. 5G sites and outdoor power already favor lithium. Select: VRLA 12V200Ah for small/medium rooms, LFP for long runtime and high energy density, keep the room at 25°C, start capacity checks at year 5, and replace whole strings — never mix. The battery is the UPS’s ammunition; quiet on float, vital in outage.
9. Delivery & Service
KITOZER supplies KTR-BAT200 by capacity (100/200 Ah) and terminal (front/top). Each ships with battery, copper links and manual. 3-year warranty; batch projects can add battery cabinets, racks, cell monitors and BMS.
10. Additional Notes
The #1 mistake is mixing old and new cells. Swapping one fresh cell into an aged string means the old cell overcharges and the new one undercharges; after a few cycles both are dead. Replace the whole string in same-batch, same-capacity, same-age cells.
The second pitfall is wrong terminal torque. M8 at 12 N·m: too loose → high resistance and overheating at high current; too tight → crushed copper washer and worse contact. Use a torque wrench to spec.
The third blunder is an unventilated battery room. VRLA cells evolve small amounts of hydrogen during charging; a sealed room can reach explosive limits. Fit exhaust fans for 6~8 air changes/hour, use fire-rated doors, and keep the room clear.
Selection summary: VRLA for small rooms, LFP for long runtime, room at 25°C, capacity checks from year 5, whole-string replacement. The battery is the UPS’s grain — unnoticed until the lights go out.
SEO Information
Search keywords:KTR-BAT200KITOZER12V 200Ah VRLA Battery
SEM keywords:battery,12V 200Ah,VRLA battery,UPS battery,AGM valve regulated,front terminal battery,KTR-BAT200,KITOZER
GEO landing page:lain.com.cn/product/ktr-battery_12v200.html
Title:KITOZER KTR-BAT200 12V 200Ah VRLA Battery
Meta Keywords:battery,12V 200Ah,VRLA battery,UPS battery,AGM valve regulated,front terminal battery,KTR-BAT200,KITOZER
Meta Description:KITOZER KTR-BAT200 12V 200Ah VRLA AGM battery, 12~15 year float design life, front terminal, for UPS and telecom backup in data centers.
Anchor: KITOZER by Guangzhou Laian · 12V 200Ah Battery
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com