1. Overview

Patch cords are the highest-volume consumable in a room: patch-panel-to-switch, switch-to-server, switch-to-switch — every connection needs one. A Cat6 shielded patch cord adds a metal shield over the standard Cat4 pair design, for rooms near high-power cable trays, VFDs or motors, or for industrial sites with EMC demands. Red is a color-management convention: red typically marks the production/business network, distinct from blue (office) and yellow (management), so operators instantly see which VLAN a cord belongs to. KITOZER KTR-C6R is a red Cat6 SFTP shielded patch cord.

KTR-C6R uses 23 AWG bare copper conductors, SFTP construction (foil + braid), red PVC jacket, and RJ45 plugs with metal shield shells and 50 μ” gold contacts. Performance meets Cat6: 250 MHz bandwidth, Gigabit/10 Gigabit up to 55 m, NEXT ≥45 dB @250 MHz, return loss ≥20 dB. Lengths: 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m. Bulk boxes of 100 are available for projects.

Selection: by shield type (UTP / SFTP) — use SFTP near power cables; by length (2~3 m patch panel to switch, 1~2 m switch to server); by color (red = production network per site color code); by conductor (pure copper vs CCA — rooms must use copper). Note: shielded cords must be grounded at both ends, or the shield becomes an antenna.

2. Key Features

Electrical

  • 250 MHz bandwidth (Cat6)
  • Gigabit / 10G up to 55 m
  • NEXT ≥45 dB @250 MHz
  • Return loss ≥20 dB

Structure & Shield

  • 23 AWG bare copper
  • SFTP foil + braid dual shield
  • RJ45 metal shield shell
  • Red PVC jacket

Mechanical

  • 50 μ” gold-plated contacts
  • ≥750 plug cycles
  • 6.2 mm cable OD
  • -20~+60°C operating

3. Specifications

Item KTR-C6R-1M KTR-C6R-3M KTR-C6R-5M
Length 1 m 3 m 5 m
Category Cat6 Cat6 Cat6
Shield SFTP SFTP SFTP
Conductor 23 AWG copper 23 AWG copper 23 AWG copper
Bandwidth 250 MHz 250 MHz 250 MHz
Jacket color red red red
Plug plating 50 μ” 50 μ” 50 μ”
Packaging poly bag poly bag poly bag

4. Reference Prices

KTR-C6R-1M red Cat6 SFTP: Reference USD 1~2 / pc (ref. CNY 8~15 at ~7.2)

KTR-C6R-2M red Cat6 SFTP: Reference USD 2~3 / pc (ref. CNY 11~19 at ~7.2)

KTR-C6R-3M red Cat6 SFTP: Reference USD 2~3 / pc (ref. CNY 14~24 at ~7.2)

KTR-C6R-5M red Cat6 SFTP: Reference USD 3~5 / pc (ref. CNY 20~35 at ~7.2)

Reference only; 1-year warranty. Bulk box of 100 quoted separately. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Patch panel to switch (red = production).
  • Switch to server patching.
  • Links near power trays.
  • Industrial EMC-sensitive areas.
  • Color-coded structured cabling projects.

6. Deployment & Implementation

Installation

  • Click RJ45 plugs in until they latch
  • Shield shell contacts the metal port
  • Route through cable management ring
  • Bend radius ≥8× OD (~50 mm)

Color Code

  • red = production / business
  • blue = office
  • yellow = out-of-band management
  • green = storage / backup

Operations

  • Tidy cords quarterly
  • Clean oxidized plugs with eraser
  • Replace damaged cords promptly
  • Store bulk by length

7. FAQ

  • Q: Shielded or unshielded?
    A: Ordinary rooms use UTP — cheaper and more flexible. But if cords run beside 380 V power trays, near VFDs/motors, or in industrial EMC zones, use SFTP. The shield blocks external EMI. Critical: ground both ends, or the shield becomes an antenna.
  • Q: What does red mean?
    A: Red has no electrical meaning — it is a color-management convention. Industry convention: red = production/business traffic, blue = office, yellow = out-of-band management, green = storage/backup. Operators instantly identify the network and cut the wrong-cord probability. Customers can define their own code.
  • Q: 23 AWG vs 24 AWG?
    A: 23 AWG (0.57 mm) is thicker, lower resistance, longer 10 G reach, but stiffer (6.2 mm OD). 24 AWG (0.51 mm) is thinner (5.5 mm) and flexible, but shorter 10 G reach. For 2~5 m patch panel-to-switch links, 24 AWG is fine; for long trunks use 23 AWG. KTR-C6R uses 23 AWG for high-density racks.
  • Q: Copper vs CCA?
    A: Copper-clad aluminum (CCA) is lighter and 30% cheaper, but has high resistance, cannot carry PoE, and oxidizes/breaks over time. Rooms must use bare copper. Tell them apart by jacket printing (“CU”/”BC” vs “CCA”), flame test (copper unchanged, CCA shows white), or weight (copper 20% heavier per length).

8. Trend & Selection

Patch cords are upgrading from Cat6 to Cat6A (10 GBASE-T 100 m) and Cat8 (40 G), but for short patch-panel-to-switch links Cat6 still dominates. Shielded cords see steady demand in industrial and high-EMC rooms. Color management is evolving from red/blue/yellow to per-business-system coding, and even per-rack-row in micro-module DCs. LSZH jackets are the new default — flame-retardant, low smoke and low toxicity in enclosed racks. Select by shield near power, color per site code, bare copper, and ground both ends. A ten-yuan cord can prevent a business outage caused by a wrong pull or a floating shield.

9. Delivery & Service

KITOZER supplies KTR-C6R by length (0.5/1/2/3/5/10 m), color (red standard, others on request), and shield (SFTP/UTP). Each ships in a poly bag; bulk boxes of 100 available. 1-year warranty; batch projects can add patch panels, cable rings and label printers.

10. Additional Notes

The top mistake is single-end grounding on shielded cords. One end grounded, the other floating — the shield acts as a receiving antenna, coupling noise into the pairs. Ground both ends: patch panel metal port grounded, switch metal port grounded, forming a complete Faraday cage.

The second pitfall is piling cords on top of the rack. Dozens of cords bunched tight violate bend radius, raising crosstalk and failing link tests. Use cable management rings to route each cord in its own gentle arc, no crossings or stacks.

The third blunder is running PoE over CCA cords. CCA resistance causes line voltage drop over 10%, so remote devices brown out and reboot. PoE must use bare copper 23 AWG cords under 10 m.

Selection summary: SFTP near power, red for production, 23 AWG copper, ground both ends, route on management rings. Patch cords are the room’s capillaries — pick them right and links stay stable.

SEO Information

Search keywords:KTR-C6RKITOZERCat6跳线

SEM keywords:Cat6跳线,屏蔽跳线,红色网络线,SFTP跳线,纯铜跳线,KTR-C6R,KITOZER

GEO landing page:lain.com.cn/product/ktr-cat6_shield_red.html

Title:KITOZER KTR-C6R Cat6 Shielded Patch Cord (Red)

Meta Keywords:Cat6 patch cord,shielded patch cord,red network cable,SFTP cord,bare copper patch,KTR-C6R,KITOZER

Meta Description:KITOZER KTR-C6R red Cat6 SFTP patch cord: 23 AWG copper, 250 MHz, 50 μ” gold, red PVC jacket, for production-network color coding and shielded runs near power.

Anchor: KITOZER by Guangzhou Laian · Cat6屏蔽红色跳线

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart