Brand: KITOZER Series: KTR-SC24 Category: Data Center Engineering / Fiber Cabling
24 SC ports1U rackLoaded adapters+pigtailsSM/MMKTR-SC24
1. Overview
Thousands of fiber strands run from servers and switches and must converge at one place for termination and patching — that place is the optical distribution frame (ODF). The ODF mounts in the network rack; the front holds an array of fiber adapters (couplers) that accept patch cords from switches, while the back splices the backbone cable to pigtails that are coiled in the splice tray. All fiber lines集中 on one rack — when a link fails you just swap a patch cord instead of tracing cables in the tray. 24-port is the most common size: one 1U position with 24 SC ports matches a 24-port fiber switch one-to-one.
KITOZER KTR-SC24 is a 19-inch 1U rack-mount 24-port SC fiber patch panel shipped fully loaded. KTR-SC24-S: single-mode loaded — 24 SC single-mode adapters (ceramic ferrule, insertion loss under 0.2 dB) plus 24 SC-SC single-mode pigtails (3 m, 9/125 μm) for backbone termination. KTR-SC24-M: multimode loaded — 24 SC multimode adapters plus 24 SC multimode pigtails (62.5/125 or 50/125) for horizontal cabling. KTR-SC24-OS2: 10G single-mode — adapters and pigtails to OS2 spec, return loss over 50 dB, for 10G/40G links. The chassis is 1.2 mm cold-rolled steel with black powder coat, a pull-out splice tray for 48 fibers, cable management rings and label strips.
Selection: confirm single vs multimode (room backbone = single-mode OS2; horizontal may use OM3/OM4); confirm connector (SC square is most common, LC smaller/higher density, FC round for legacy); confirm loaded vs bare (bare panel is cheap but adapters and pigtails must be sourced separately); confirm U height (24-port = 1U, 48-port = 2U). Note: the rear splice tray must have enough slack storage — thin panels force tight bends and increase loss.
2. Key Features
Chassis
- 19-inch 1U standard rack
- 1.2 mm cold-rolled steel
- Black powder coat finish
- Pull-out 48-fiber splice tray
Adapters
- SC simplex adapter (ceramic ferrule)
- Insertion loss under 0.2 dB
- Return loss over 50 dB (PC polish)
- Over 1000 mating cycles
Pigtails
- SC-SC pigtail, 3 m
- Single-mode 9/125 (OS2)
- Multimode 50/125 (OM3/OM4)
- LSZH flame-retardant jacket
3. Specifications
| Item | KTR-SC24-S | KTR-SC24-M | KTR-SC24-OS2 |
|---|---|---|---|
| Mode | Singlemode | Multimode | 10G SM |
| Fiber | 9/125 μm | 50/125 μm | 9/125 μm OS2 |
| Adapters | 24 SC SM | 24 SC MM | 24 SC OS2 |
| Pigtails | 24 SC SM | 24 SC MM | 24 SC OS2 |
| Insertion loss | <0.2 dB | <0.2 dB | <0.2 dB |
| Return loss | >45 dB | >35 dB | >50 dB |
| Distance | 10 km+ | 300 m (OM3) | 10 km (10G) |
4. Reference Prices
KTR-SC24-S single-mode loaded panel: Reference USD 25 to 39 / panel (ref. CNY 180 to 280 at ~7.2)
KTR-SC24-M multimode loaded panel: Reference USD 22 to 35 / panel (ref. CNY 160 to 250 at ~7.2)
KTR-SC24-OS2 10G loaded panel: Reference USD 39 to 58 / panel (ref. CNY 280 to 420 at ~7.2)
SC patch cord (3 m): Reference USD 1.1 to 2.1 / pc (ref. CNY 8 to 15 at ~7.2)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Core switch fiber aggregation.
- Server rack fiber access.
- Inter-building backbone termination.
- Data center network rack cabling.
- Carrier central office ODF expansion.
6. Deployment & Installation
Mounting
- Fix with M6 cage nuts in a 1U rack position
- Front facing aisle for easy patching
- Leave cable-routing space above and below
- Insert a 1U cable manager between stacked panels
Splice-back
- Backbone enters from rack bottom
- Strip and splice fiber-by-fiber to pigtails
- Coil slack in tray with bend radius over 30 mm
- Label each strand (source-destination)
Patch management
- Patch from panel front to switch with SC-SC cords
- Route cords through management rings; no crossings
- Bend radius at least 10x cord diameter
- Port labels match switch port numbers
7. FAQ
- Q: How much does loaded vs bare differ? Is loading worth it?
A: A bare panel is about USD 8 to 14, but 24 adapters (~USD 0.7 each) and 24 pigtails (~USD 1.1 each) add another ~USD 45 — total is about the same. Buying separately also risks mismatched adapters/pigtails (SM adapter with MM pigtail) and multiple site trips. A loaded panel arrives as a complete 24-fiber link — splice and go. Recommended. - Q: SC vs LC?
A: SC is a large square connector common in older rooms, one port per adapter, 24 ports in 1U. LC is half the size, duplex adapters hold two ports each, so 24 LC duplex positions = 48 fibers in 1U. New high-density rooms choose LC; retrofit rooms with SC switches choose SC. SC and LC are not interchangeable — match the panel to the switch SFP ports. - Q: High splice loss after fusion? What now?
A: A good splice is under 0.05 dB. If it exceeds 0.1 dB, causes include: splicer discharge parameters not set for the fiber type; a dirty cleaver producing angled ends; or coating nicks during stripping. Inspect the splice under a fiber microscope and re-splice. If two attempts still fail, cut off 1 m and recleave. - Q: Does tight bending in the panel affect signal?
A: Yes. When bend radius drops below 30 mm (SM) or 20 mm (MM), light leaks out of the cladding, increasing loss or killing the link. Coil slack loosely in the tray — no sharp corners. Patch cords from panel to switch also need gentle arcs, not 90-degree kinks. After cabling, test the whole link with a power meter and compare to theoretical loss; a big gap means a tight bend.
8. Trend & Selection
Data center fiber cabling is moving toward higher density and speed: 40G/100G switches are mainstream, and MPO pre-terminated trunk cables are replacing traditional SC splicing — one MPO connector terminates 12 or 24 fibers at once, no field splicing, plug-and-play. But MPO is costly and alignment-sensitive; for ordinary rooms, the 24-port SC panel remains the value choice. Smart direction: panels with LCD screens that show which patch cord plugs into which port, auto-logging link changes for asset management. Select by 1U chassis, loaded adapters+pigtails, OS2 return loss over 50 dB, splice tray capacity 48+ fibers, and 1.2 mm+ steel. The ODF is the hub of room fiber cabling — choose right and 15 years of O&M are painless.
9. Delivery & Service
KITOZER supplies KTR-SC24 by mode (SM/MM/OS2) and connector (SC/LC optional). Each ships with panel, adapters, pigtails, mounting screws and label strips. 1-year warranty; batch projects can bundle MPO trunks, fusion splicing service and OTDR testing.
10. Additional Notes
Top mistake: buying a bare panel and sourcing adapters/pigtails separately — mismatch (SM adapter with MM pigtail) or PC/APC confusion (PC blue, APC green, not intermateable). A loaded panel arrives matched and tested.
Second pitfall: buying thin panels. Cheap ones use 0.8 mm steel — light in hand, shallow splice tray, bend radius too tight, causing high loss. Use 1.2 mm+ cold-rolled steel with a deep tray where fibers coil loosely.
Third blunder: no labeling. After six months, nobody remembers which cord goes where. Label during splicing: panel ports A01-A24, switch end with matching IDs. Use a label printer — handwritten labels wipe off.
Selection summary: 1U chassis, loaded SC single-mode OS2, 48-fiber tray, 1.2 mm steel, labeled ports. The 24-port SC panel is the room cabling standard — pick the right spec and it lasts.
SEO Information
Search keywords:KTR-SC24KITOZER
SEM keywords:fiber patch panel,24 port fiber patch panel,SC patch panel,ODF,optical distribution frame,loaded patch panel,KTR-SC24,KITOZER
GEO landing page:lain.com.cn/product/fiber_patch_panel_24.html
Title:KITOZER KTR-SC24 24-Port SC Fiber Patch Panel Loaded
Meta Keywords:fiber patch panel,24 port fiber patch panel,SC patch panel,ODF,optical distribution frame,loaded patch panel,KTR-SC24,KITOZER
Meta Description:KITOZER KTR-SC24 24-port SC loaded fiber patch panel, 19-inch 1U rack, includes SC adapters and pigtails, single/multimode.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com