Brand: KITOZER Series: KTR-FB48 Category: Data Center Engineering / High-Density Fiber
48 LC duplex2U rack96 fibersDrawerKTR-FB48
1. Overview
Data center fiber density keeps climbing — a single 48-port fiber switch needs 48 ports, plus redundancy, backup, and multiple service lines. One network rack can host hundreds of fibers. A 24-port SC panel works but wastes U space at 24 fibers per 1U. The 48-port LC patch box is built for high density: LC small-form-factor duplex adapters, two ports (TX/RX) per adapter, 48 LC duplex positions terminate 96 fibers in just 2U. The drawer slides out — the front panel pulls forward and the rear splice tray slides out too — so splicing and organizing happen outside the rack without contorted hands. The 48-port box is the standard in mid-to-large data centers, matching 48-port core switches one-to-one.
KITOZER KTR-FB48 is a 19-inch 2U rack 48-port LC duplex fiber patch box. KTR-FB48-S: single-mode loaded — 48 LC simplex duplex adapters (ceramic ferrule, actually 96 fibers) plus 96 LC single-mode pigtails (OS2, 9/125 μm), insertion loss under 0.2 dB, return loss over 50 dB — for backbone links. KTR-FB48-M: multimode loaded — 48 LC MM adapters plus 96 OM4 pigtails (50/125 μm) — for 10G-to-desk. KTR-FB48-MPO: pre-terminated — 48 LC duplex front, 4x MPO-12 rear adapters, backbone MPO trunk plugs in directly, no field splicing — for fast high-density deployment. Chassis is 1.2 mm cold-rolled steel, black powder coat, smooth drawer slides, 96-fiber splice tray, cable rings and label strips.
Selection: confirm SM vs MM (OS2 for backbone, OM4 for access); confirm MPO pre-term (recommended for new high-density rooms to save splicing); confirm U height (48 LC = 2U; 96 ports need 4U); confirm adapter color (SM blue PC, MM aqua OM4, APC green). Note: LC adapters are small and fragile — insert patch cords gently; do not force.
2. Key Features
Density
- 48 LC duplex = 96 fibers
- 2U standard rack
- Sliding drawer front
- 96-fiber rear tray
Optical
- Ceramic ferrule adapters
- Insertion loss under 0.2 dB
- Return loss over 50 dB (OS2)
- Over 500 mating cycles
Build
- 1.2 mm cold-rolled steel
- Black powder coat
- Stainless slides
- Cable rings + label strips
3. Specifications
| Item | KTR-FB48-S | KTR-FB48-M | KTR-FB48-MPO |
|---|---|---|---|
| Mode | SM OS2 | MM OM4 | MPO pre-term |
| Ports | 48 LC dpx (96f) | 48 LC dpx (96f) | 48 LC dpx + 4 MPO |
| Pigtails | 96 LC SM | 96 LC MM | MPO trunk |
| Insertion loss | <0.2 dB | <0.2 dB | <0.3 dB |
| Return loss | >50 dB | >35 dB | >50 dB |
| U height | 2U | 2U | 2U |
| Use | Backbone | 10G access | Fast deployment |
4. Reference Prices
KTR-FB48-S SM loaded 96-fiber: Reference USD 76 to 118 / panel (ref. CNY 550 to 850 at ~7.2)
KTR-FB48-M OM4 loaded: Reference USD 69 to 108 / panel (ref. CNY 500 to 780 at ~7.2)
KTR-FB48-MPO pre-terminated: Reference USD 125 to 194 / panel (ref. CNY 900 to 1400 at ~7.2)
LC-LC patch cord (3 m): Reference USD 1.4 to 2.5 / pc (ref. CNY 10 to 18 at ~7.2)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Core switch high-density fiber aggregation.
- Server rack Top-of-Rack access.
- Data center structured cabling.
- Fiber-to-the-desk (FTTD).
- Carrier central office ODF expansion.
6. Deployment & Installation
Mounting
- M6 screws in a 2U rack position
- Front facing cold aisle
- Insert 1U cable manager between stacked panels
- Drawer travel must not hit rear patch cords
Splice / Pre-term
- Splice model: strip backbone and splice fiber-by-fiber
- MPO model: plug MPO trunk directly into rear adapters
- Coil slack in drawer tray, bend radius over 30 mm
- Label each port (switch port number)
Patch Management
- Patch front to switch SFP+ with LC-LC cords
- Route through top rings in gentle arcs
- No crossings, no sharp bends
- Labels legible at each port
7. FAQ
- Q: 48 LC vs 24 SC?
A: 24 SC uses 1U for 24 fibers; 48 LC uses 2U for 96 fibers — 4x the density in the same 2U. New high-density rooms all use LC. But LC plugs are small and easy to drop; SC plugs are large and rugged. Retrofit rooms with SC switches stay with SC; new rooms with SFP+ switches go LC. Remember: LC duplex = TX+RX, so count x2 for fiber count. - Q: MPO pre-term vs field splicing?
A: MPO pre-terminated trunks are factory-terminated; on site you plug directly into the rear MPO adapter — no fusion splicer, no technician, fast. But trunks must be custom-cut to drawing lengths and re-patching is harder. Field splicing is flexible (any cable, any length) but needs a splicer and skilled labor. New standard data centers use MPO (fast); retrofits and non-standard lengths use field splicing (flexible). - Q: Will the drawer break when pulled out?
A: No — stainless slides rated over 5 kg carry the splice tray. But pull slowly; do not yank the front panel. When patching cords are plugged in the front, do not pull the drawer — cord length will yank adapters off the back. For splicing, unplug front cords first, then slide out. - Q: How many 48-port boxes per rack?
A: A standard 42U rack reserves 10-15U for network cabling. Each 48-port box is 2U plus 1U cable manager above/below = 4U. So 3-4 boxes per rack = 288-384 fibers, matching 3-4 switches. Server racks typically host 1-2 boxes for local ToR switches.
8. Trend & Selection
Data center fiber is moving wholesale to MPO pre-terminated high-density systems: 40G/100G switches use MPO-12/MPO-16; the patch box presents LC on the front and MPO on the back with an MPO-LC cassette converting 12 fibers. Whole-cabinet pre-terminated systems are built to drawing in the factory and plug together on site — no fusion splicing. Smart patch panels with electronic port ID auto-detect plug inserts and feed asset management. But the LC splice-style 48-port box remains the value choice in small-to-mid rooms. Select by: 2U 48 LC duplex 96 fibers, OS2 return loss over 50 dB, drawer for service, 96-fiber tray, clear labels. The 48-port box is the high-density room standard — one rack replaces four old ones.
9. Delivery & Service
KITOZER supplies KTR-FB48 by mode (SM/MM/MPO) and configuration (bare/loaded). Each ships with box, adapters, pigtails, slides and screws. 1-year warranty; batch projects can bundle MPO trunks, LC patch cords and fusion splicing service.
10. Additional Notes
Top mistake: buying a bare box and sourcing pigtails separately, then mixing LC with SC. LC and SC adapters are different sizes and not interchangeable. Decide LC or SC before ordering. Loaded panels arrive matched and tested.
Second pitfall: pulling the drawer with cords plugged in. The cords are only so long — the drawer travel rips adapters off the rear. Unplug front cords before sliding out.
Third blunder: never cleaning adapter end-faces. Dust builds up inside adapters and increases loss. Clean end-faces monthly with a fiber cleanup pen. Dirty adapters cause intermittent links that are hard to debug.
Selection summary: 2U 48 LC duplex 96 fibers, OS2 SM, drawer service, MPO option, labeled ports. The 48-port box is the high-density room workhorse, one-to-one with 48-port switches, tidy and maintainable.
SEO Information
Search keywords:KTR-FB48KITOZER
SEM keywords:fiber patch box,48 port fiber box,rack mount fiber box,ODF box,LC patch panel,KTR-FB48,KITOZER
GEO landing page:lain.com.cn/product/fiber_box_48.html
Title:KITOZER KTR-FB48 48-Port Rack Fiber Patch Box
Meta Keywords:fiber patch box,48 port fiber box,rack mount fiber box,ODF box,LC patch panel,KTR-FB48,KITOZER
Meta Description:KITOZER KTR-FB48 48-port rack fiber patch box, 2U, LC duplex loaded, 96 fibers, high-density data center cabling.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com