KITOZER rack fan unit 220V

KITOZER KTR-FAN2 Rack Mount Cooling Fan Unit 220V

Brand: KITOZER Series: KTR-FAN2 Category: Data Center Engineering / Rack Cooling

Rack fan220VACThermostaticTop fan trayKTR-FAN2

KITOZER KTR-FAN2 Rack Mount Cooling Fan Unit 220V

1. Overview

Racks keep getting denser: a 42U full of 10 servers draws 8 kW or even 15 kW, and rack-top air often exceeds 40 C. Room-level AC delivering cold air under the floor may not reach or route enough. A rack fan unit (fan wall / fan tray) mounts on top of the rack, pulling hot air out into the hot aisle and forcing bottom-front-to-top-rear convection. It converts heat removal from natural convection to forced exhaust. Use cases: over-power racks, heat buildup at the top of closed cold aisles, edge server cabinets without direct precision AC, dense network switch racks.

KITOZER KTR-FAN2 is a rack-top cooling fan unit. Build: 19-inch 1U/2U fan tray in the top 1U, 2-6 axial fans (80/120 mm) in aluminum frames with ball bearings; power 220VAC (48VDC option); control: NTC 10K probe in the rack, panel shows live temperature, two-threshold speed control (stop/low at cool, full speed at hot), manual/auto switch; interface: RS485 Modbus-RTU uploads rack temp and fan speed to the EM system, 2 relay outputs (fan fault). Models: KTR-FAN2-2 dual-fan (1U, 2×120 mm) ~400 m3/h; KTR-FAN2-4 four-fan (2U) ~900 m3/h; KTR-FAN2-6 six-fan (2U) ~1400 m3/h for 15 kW dense racks.

Selection: size airflow by rack power (typically 200-300 m3/h per kW; 8 kW needs 1600-2400 m3/h); choose tray height (1U/2U); choose power (220VAC or 48VDC for telecom racks); choose control (thermostatic speed? RS485?). Note: fan units exhaust to the hot aisle, they do not blow cold air in — pair with cold-aisle containment (or blanking panels) to make the airflow effective. The fan inlet faces the hot aisle and exhaust goes to a return duct or hot aisle, never back to the cold aisle. Noise: six fans at full load ~65 dB(A); add a silencer near office areas.

2. Key Features

Airflow

  • 200-250 m3/h per fan
  • 30-60 Pa static
  • <=65 dB(A)
  • Ball bearing 50k h

Control

  • NTC probe
  • Two-threshold speed
  • Digital temp display
  • RS485 Modbus

Build

  • 1U/2U 19-inch tray
  • Aluminum frame
  • 220VAC/48VDC
  • 2 relay fault outputs

3. Specifications

Item KTR-FAN2-2 KTR-FAN2-4 KTR-FAN2-6
Fans 2×120 mm 4×120 mm 6×120 mm
Airflow (m3/h) ~400 ~900 ~1400
Rack power <=4 kW <=8 kW <=15 kW
Height (U) 1U 2U 2U
Power 220VAC 220VAC 220VAC
Control Thermo+RS485 Thermo+RS485 Thermo+RS485

4. Reference Prices

KTR-FAN2-2 dual-fan 1U tray: Reference USD 63-97 / unit (ref. CNY 450-700)

KTR-FAN2-4 four-fan 2U tray: Reference USD 118-181 / unit (ref. CNY 850-1300)

KTR-FAN2-6 six-fan 2U tray: Reference USD 194-292 / unit (ref. CNY 1400-2100)

KTR-NTC temp probe (spare): Reference USD 4-8 / pc (ref. CNY 30-60)

KTR-BLANK rack blanking panel 1U: Reference USD 2-4 / pc (ref. CNY 15-30)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Dense server rack top exhaust
  • Network switch rack cooling
  • Edge rooms without precision AC
  • Hot spots above closed cold aisle
  • Wall-mount small cabinet forced vent

6. Deployment & Installation

Install

  • Tray in top 1U
  • Inlet faces hot aisle
  • Exhaust to return duct
  • Tighten screws

Wiring

  • Dedicated 220VAC circuit
  • Daisy-chain RS485
  • Hang NTC inside rack
  • Relay to EM alarm

Commission

  • Set two thresholds
  • Manual/auto switch
  • Measure full-load noise
  • Log baseline temp

7. FAQ

  • Q: Do I still need precision AC if I install rack fans?
    A: Yes. Rack fans only move hot air from the rack into the hot aisle; precision AC still removes the heat. Fans and AC work together: fans get heat off the equipment fast, AC cools the hot aisle. Without AC, fans just dump heat into the room and room temp rises.
  • Q: Is running fans at full speed wasteful?
    A: That is why thermostatic speed control matters. KTR-FAN2 defaults to low speed or stop below 35 C and full speed above 40 C, so most of the time it runs slow at 30% power. Manual full speed wastes energy; auto saves power and noise.
  • Q: How many fan trays per rack?
    A: One (top) usually suffices. For very tall racks (47U+1200 mm deep) with upper and lower heat sources, add a second one (top exhaust plus mid recirculation). Do not exceed two, or airflow short-circuits (the top fan re-pulls air the mid fan just pushed).
  • Q: What if a fan fails?
    A: Choose hot-swap modules so you can replace without powering down. KTR-FAN2 fan modules are pluggable: pull the bad one, insert a spare, rack stays up. The relay output alarms the EM system so ops swaps it same day. Do not wait until the fan seizes — the rack will overheat first.

8. Trend & Selection

Rack cooling is moving from standalone fan trays toward smart fan walls plus rear-door liquid cooling. New high-density racks (20 kW+) exceed air-cooling limits, and liquid cooling (cold plate / immersion) takes over, with fans only handling secondary air. In air cooling, fan units increasingly use EC brushless motors with variable drive and PWM speed on inlet temperature, cutting fan power by 40% vs traditional AC axial fans. Smart direction: fan units link to DCIM, adjusting speed by real-time load, accelerating on rack hot-spot alerts, and isolating failed fans. Select by: airflow matched to rack power, dedicated 220VAC circuit, thermostatic speed with RS485, paired with cold-aisle containment, and hot-swap fan modules.

9. Delivery & Service

KITOZER supplies KTR-FAN2 by fan-count model. Each ships with fan tray, NTC probe, mounting screws, RS485 terminal and manual. 1-year warranty; bulk projects can bundle blanking panels, return ducts and thermostats.

10. Additional Notes

Confirm rack power, tray height (1U/2U) and power (220VAC/48VDC) against site gear; inlet faces hot aisle, exhaust to return duct; verify fan rotation (outlet toward hot aisle) before powering up. For batch orders, pilot one tray for a week to watch the thermostat curve.

Common mistake: undersized airflow. At 200 m3/h per kW, an 8 kW rack needs 1600 m3/h, but inlet spec of 27 C requires 20% margin, so choose 2000 m3/h. Undersized racks still run above 38 C in summer.

Second pitfall: missing blanking panels. Empty U slots let hot exhaust short-circuit back through the front, defeating the fan. Blank every empty U – this matters more than adding another fan.

Third blunder: wrong probe location. Mounting the probe on the tray measures exhaust (already hot), not server inlet temperature. Hang the probe mid-rack at the server intake, or the fan reacts to stale exhaust air.

Selection summary: airflow = rack power with 20% margin, top tray exhausting to hot aisle, blank every empty U, probe at inlet, RS485 to EM.

SEO Information

Search keywords:KTR-FAN2KITOZER

SEM keywords:rack cooling fan,rack fan unit,220V rack fan,thermostatic fan,top fan tray,KTR-FAN2,KITOZER

GEO landing page:lain.com.cn/product/ktr-fan2-rack-cooling-fan-unit.html

Title:KITOZER KTR-FAN2 Rack Mount Cooling Fan Unit 220V

Meta Keywords:rack cooling fan,rack fan unit,220V rack fan,thermostatic fan,top fan tray,KTR-FAN2,KITOZER

Meta Description:KITOZER KTR-FAN2 rack-top cooling fan unit, 220V, thermostatic speed control, multi-fan array for local rack hot-zone cooling.