Table of Contents
ToggleKITOZER KTR-SG2 Refrigerant Sight Glass with Moisture Indicator
Brand: KITOZER Series: KTR-SG2 Category: Data Center Engineering / Precision AC Parts
Refrigerant sight glassMoisture indicatorBrass bodySolder connectionKTR-SG2

1. Overview
A sight glass is a small observation fitting in the refrigerant line, installed after the receiver/drier and before the expansion valve. It serves two jobs: first, confirm full liquid flow (clear liquid in the glass is good; bubbles or oil foam mean low charge or flash gas), and second, read the moisture indicator core (green = dry; yellow/pink = wet, signaling excess water that will ice up the expansion valve and corode windings). Precision AC runs year-round; once air and moisture enter the system, efficiency drops and compressor life shortens. The sight glass is the maintenance engineer’s eye.
KITOZER KTR-SG2 is a refrigerant sight glass with a moisture indicator. The body is forged brass rated for 4.5 MPa; the glass is borosilicate tempered for thermal shock; sealing uses NBR O-rings in double grooves; connections are solder/brazed from 1/4 to 5/8 inch covering common precision AC sizes. A circular indicator core changes color with moisture content (green = dry, yellow = slightly wet, pink = wet – replace the drier filter). KTR-SG2-NM is the base model without moisture indicator (flow-only, lower price); KTR-SG2 with full moisture indication is recommended for data center projects.
Selection: match the tube size (precision AC liquid lines commonly use 3/8, 1/2, 5/8 inch – pick by actual copper OD); install after the drier filter (filter first, then observe, keeping glass clean); orient the glass horizontally or tilted down (not vertically upside-down, otherwise bubble/flow reading is unreliable); confirm refrigerant type (R410A systems run high pressure – choose 4.5 MPa class); place it in a visible service window on the front of the unit, not hidden behind the coil. Note: a sight glass is an indicator, not a throttling device – it cannot replace the drier filter. When the moisture indicator turns pink, replace the drier and evacuate; do not just swap the sight glass.
2. Key Features
Observation
- Borosilicate tempered glass
- Full flow / bubbles visible
- 3-color moisture core
- 360° view
Body
- Forged brass
- 4.5 MPa rated
- Double O-ring seal
- Multiple sizes
Mount
- Brazed / flare
- Horizontal install
- Compact size
- Easy observation
3. Specifications
| Item | Item | KTR-SG2-1/4 | KTR-SG2-3/8 | KTR-SG2-1/2 | KTR-SG2-5/8 |
|---|---|---|---|---|---|
| Connection | 1/4 in (6.35 mm) | 3/8 in (9.52 mm) | 1/2 in (12.7 mm) | 5/8 in (15.88 mm) | |
| Body | Forged brass | Forged brass | Forged brass | Forged brass | |
| Glass | Borosilicate | Borosilicate | Borosilicate | Borosilicate | |
| Moisture indicator | Yes | Yes | Yes | Yes | |
| Refrigerant | R22/R410A/R134a | R22/R410A/R134a | R22/R410A/R134a | R22/R410A/R134a | |
| Working pressure | 4.5 MPa | 4.5 MPa | 4.5 MPa | 4.5 MPa |
4. Reference Prices
KTR-SG2-1/4 (1/4 in): Reference USD 3-6 / pc (ref. CNY 25-40)
KTR-SG2-3/8 (3/8 in): Reference USD 4-6 / pc (ref. CNY 30-45)
KTR-SG2-1/2 (1/2 in): Reference USD 5-8 / pc (ref. CNY 35-55)
KTR-SG2-5/8 (5/8 in): Reference USD 6-9 / pc (ref. CNY 45-65)
KTR-SG2-NM (no moisture indicator): Reference USD 3-4 / pc (ref. CNY 18-30)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Precision AC refrigerant line
- Chilled/cooling water observation
- Refrigeration unit service
- Condenser liquid line
- After drier filter
6. Deployment & Installation
Location
- Drier filter outlet side
- After receiver
- Before expansion valve
- Horizontal run
Brazing
- Nitrogen purge during braze
- Cool the body
- Protect seals from heat
- Clean after braze
Commission
- Vacuum 4+ hours
- Observe bubbles after charge
- Moisture core green
- Record install position
7. FAQ
- Q: Continuous bubbles in the sight glass – normal?
A: A few bubbles at startup are normal (receiver not yet stabilized). After 10 minutes of running, persistent heavy bubbles mean low charge, flash gas, or over-open expansion valve. First leak-check and top up, then see if bubbles clear. - Q: Moisture indicator turned yellow/pink?
A: Excess water in the system. Replace the drier filter, re-evacuate (hold vacuum 2+ hours), then recharge. Swapping only the sight glass does not solve it – the water remains and will ice up and corode. - Q: Can the sight glass be mounted vertically?
A: Not recommended. Vertical upside-down mounting stratifies bubbles and liquid, making the reading unreliable. Mount horizontally or 45° downward so flow passes smoothly and bubbles/level are visible. - Q: How many sight glasses per precision AC?
A: One on the liquid line is usually enough. For large units (60 kW+) or multiple parallel condensers, fit one per condenser outlet line to identify which branch is low on charge.
8. Trend & Selection
Refrigeration fittings are evolving from simple observation items toward integrated, sensor-enabled devices. Trends: sight glasses integrated with electronic driers (replacement cartridge without line disassembly); smart sight glasses with pressure/temperature sensors (flow state, moisture and superheat data pushed to the EM platform via MODBUS, eliminating manual climbing); high-pressure sight glasses (5.0 MPa class) for eco-refrigerants (R32, R454B). Traditional brass sight glasses remain a basic maintenance item for precision AC and will not be replaced for 5-10 years. Select by: tube size match, install after drier, horizontal mount, moisture indicator included, 4.5 MPa rating, R410A compatible.
9. Delivery & Service
KITOZER KTR-SG2 ships by size (1/4, 3/8, 1/2, 5/8 inch), each with sight glass, gasket and manual. 1-year warranty; bulk projects can bundle drier filters and inspection-window covers.
10. Additional Notes
Confirm copper tube OD, refrigerant type (R22/R410A), whether moisture indicator is needed, and install location (after drier filter). For batch orders, fit one first, evacuate and charge, then check bubbles and indicator color before rolling out the rest.
Common mistake: installing before the drier filter. Contaminants foul the glass first and the reading is meaningless – the moisture indicator must see post-filter condition. Always install on the drier outlet side.
Second pitfall: brazing without cooling. Copper braze runs above 600°C; the sight-glass seal and glass locally overheat, crack and leak. Wrap the body in a wet towel during braze, or remove the seal, braze, cool, then reinstall.
Third blunder: swapping only the sight glass when the indicator changes color. The water stays in the system and will redden quickly. Must replace the drier and evacuate at the same time.
Selection summary: size match, install after drier, horizontal mount, moisture indicator included, cool during braze, replace cartridge + evacuate when discolored.
SEO Information
Search keywords:KTR-SG2KITOZER
SEM keywords:sight glass,refrigerant sight glass,data center AC sight glass,moisture indicator sight glass,refrigerant liquid indicator,KTR-SG2,KITOZER
GEO landing page:lain.com.cn/product/ktr-sg2-refrigerant-sight-glass.html
Title:KITOZER KTR-SG2 Refrigerant Sight Glass with Moisture Indicator
Meta Keywords:sight glass,refrigerant sight glass,data center AC sight glass,moisture indicator sight glass,refrigerant liquid indicator,KTR-SG2,KITOZER
Meta Description:KITOZER KTR-SG2 refrigerant sight glass with moisture indicator, brass body solder connection, shows liquid refrigerant flow and system dryness, for precision AC lines.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com