KITOZER rack PDU 16A 8 outlet

KITOZER KTR-PDU2 Rack PDU 16A 8-Outlet Vertical Power Distribution

Brand: KITOZER Series: KTR-PDU2 Category: Data Center Engineering / Rack Power

16A input8x GB outletVerticalSurgeAluminumKTR-PDU2

1. Overview

A PDU (Power Distribution Unit) is the rack’s “power strip” that delivers UPS output to each server/switch. Unlike a home strip, a rack PDU mounts vertically on rack posts (saving U-space), uses an aluminum housing for heat dissipation, has a master breaker (a trip does not take down the upstream row cabinet), built-in surge protection, and outlet/connector types matched to equipment. In modular cold aisle cabinets, each rack typically gets two PDUs (A/B feeds) for N+1 redundancy; dual-power devices plug one cord into A and one into B, so a feed loss is taken over by the other.

KITOZER KTR-PDU2 is a 16A-input, 8x GB 10A-outlet vertical rack PDU. Input is a 16A GB plug (or terminal block); output has 8x 10A GB 5-hole sockets (matching domestic servers, switches and firewalls); master is a 16A breaker (overload/short-circuit); built-in surge module (10 kA with status window); aluminum extrusion housing, cool and rust-free; LED shows power status; mounts vertically (L-bracket on rack post) or horizontally (top/bottom); length about 1.5 m with 2.5 mm² copper cord. Models: KTR-PDU2-8M basic surge; KTR-PDU2-8S metered (V/A/kW display, connects to EM platform); KTR-PDU2-8M2 terminal-input (no plug, field-wired); KTR-PDU2-8I C13 output (for imported servers, UPS and switches with C14 inlets).

Selection: input type (16A GB plug for domestic; C14 for imported equipment rooms); outlet type (GB 5-hole for domestic gear; C13 for imported; mix means both); outlet count (8 for typical racks; 16 for dense server racks); monitoring need (basic for ordinary projects; metered with EM for rack-level energy reporting); dual-feed redundancy (A/B pair per rack, dual-power devices split across feeds, avoiding single points); cord gauge (16A needs 2.5 mm² – do not use 1.5 mm² thin cord, which causes voltage drop and heating). Note: never daisy-chain PDUs; total load must not exceed rating (16A x 220 V = 3520 W across all 8 outlets).

2. Key Features

Distribution

  • 16A input
  • 8x GB output
  • 16A master breaker
  • 2.5 mm² cord

Protection

  • Built-in SPD
  • Overload/short protection
  • Status window
  • Aluminum housing

Mount

  • Vertical L-bracket
  • Horizontal option
  • U-space saving
  • 1.5 m cord

3. Specifications

Item Item KTR-PDU2-8M KTR-PDU2-8S KTR-PDU2-8M2 KTR-PDU2-8I
Input 16A GB plug 16A GB plug 16A terminal 16A C14 plug
Output 8x 10A GB 8x 10A GB 8x 10A GB 8x C13
Master 16A breaker 16A breaker 16A breaker 16A breaker
Surge Yes Yes + meter Yes No
Housing Aluminum Aluminum Aluminum Cold-rolled steel
Mount Vertical/horizontal Vertical/horizontal Vertical Vertical

4. Reference Prices

KTR-PDU2-8M basic surge: Reference USD 12-18 / pc (ref. CNY 85-130)

KTR-PDU2-8S metered surge (V/A/kW): Reference USD 21-31 / pc (ref. CNY 150-220)

KTR-PDU2-8M2 terminal input: Reference USD 15-22 / pc (ref. CNY 110-160)

KTR-PDU2-8I C13 server version: Reference USD 13-19 / pc (ref. CNY 95-140)

KTR-PDU2-16M 16-outlet extended: Reference USD 21-32 / pc (ref. CNY 150-230)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Cold aisle cabinet
  • Server rack
  • Network rack
  • UPS output distribution
  • Dual A/B feed

6. Deployment & Installation

Mount

  • Vertical on rack post
  • L-bracket fixed
  • A/B feeds separated
  • Do not block airflow

Wiring

  • Input to UPS output
  • 2.5 mm² gauge
  • Phase/neutral/ground correct
  • Torque terminals

Power-up

  • Close breaker no-load
  • Measure output V
  • Plug devices one by one
  • Record load distribution

7. FAQ

  • Q: Why two PDUs per rack?
    A: Dual-feed redundancy. Servers and switches have dual power supplies (if one fails the other keeps running); feed A connects to UPS1, feed B to UPS2, from different UPS and different distribution cabinets. If one UPS fails or one PDU trips, the device’s other supply keeps the business online. One PDU is a single point – a PDU failure blacks out the whole rack.
  • Q: Can all 8 outlets run at full load?
    A: No. 16A x 220 V = 3520 W is the cap across all 8. A typical server draws 300-500 W; 8 fully loaded servers could exceed 4000 W and trip. Plan at 60-70% load (about 2000-2500 W) to leave headroom.
  • Q: What does the metered model add?
    A: The metered model shows real-time V, A and kW, and pushes data via RS485/MODBUS to the EM platform. Operators see rack-level A/B load on the dashboard and catch overload or imbalance (two feeds carrying very different loads) early. Ordinary rooms use the basic model, but new builds should spec metered to leave energy-management hooks.
  • Q: Can C13 and GB 5-hole be mixed?
    A: Some PDUs mix them, but KTR-PDU2 is designed as pure-GB or pure-C13. If a rack has both domestic servers (GB plug) and imported gear (C14 inlet), buy two PDUs – one GB, one C13 – rather than a mixed strip, which suffers poor contact.

8. Trend & Selection

Rack PDUs are evolving from simple strips toward smart, remotely-managed rack power. Trends: metered PDUs (per-outlet metering down to the socket, for fine-grained energy management and billing); switched PDUs (remote on/off per outlet, rebooting servers without walking to the rack); 4G/Modbus cloud-connected PDUs (no EM host, data straight to cloud, for small rooms); PDUs integrated into modular cold aisle cabinets (built into the rack posts, cleaner look, shorter cords). Traditional basic PDUs remain mainstream in ordinary rooms, but new builds and dense racks increasingly choose metered/switched versions. Select by: 16A input, 2.5 mm² cord, A/B dual feed, outlet type match, plan at 70% load, leave metering/remote hooks.

9. Delivery & Service

KITOZER KTR-PDU2 ships by model (basic/metered/terminal/C13), each with PDU, L-bracket, power cord and manual. 1-year warranty; bulk projects can bundle racks, UPS and row cabinets.

10. Additional Notes

Confirm input type (GB plug/C14), output type (GB 5-hole/C13), outlet count (8/16), metering need, and cord length (default 1.5 m, longer custom). For batch orders, load-test one at 70% for 2 hours – housing should not feel hot to the touch.

Common mistake: daisy-chaining PDUs. One PDU plugged into another pushes all downstream load onto the upstream unit; the upstream 16A breaker trips while downstream gear is not even at capacity. Daisy-chaining also adds contact points and failure points. PDUs must connect directly to UPS output – no chain.

Second pitfall: A/B dual feed actually fed from one UPS. The design calls for feed A on UPS1 and feed B on UPS2 (different cabinets), but construction shortcuts both feeds onto one UPS. When that UPS fails, both feeds drop – redundancy is illusory. After install, verify: which UPS is feed A, which is feed B – they must not share.

Third blunder: undersized cord. A 16A PDU with a 1.5 mm² cord (it plugs in, so it looks OK) heats up and drops voltage under sustained load. 16A needs 2.5 mm²; upgrade to 4 mm² if the run exceeds 3 m.

Selection summary: 16A input, 2.5 mm² cord, A/B on different UPS, outlet type match, plan at 70% load, no daisy chain.

SEO Information

Search keywords:KTR-PDU2KITOZER

SEM keywords:rack PDU,16A PDU,8-outlet GB PDU,vertical PDU,rack power strip,KTR-PDU2,KITOZER

GEO landing page:lain.com.cn/product/ktr-pdu2-rack-pdu-16a-8outlet.html

Title:KITOZER KTR-PDU2 Rack PDU 16A 8-Outlet Vertical Power Distribution

Meta Keywords:rack PDU,16A PDU,8-outlet GB PDU,vertical PDU,rack power strip,KTR-PDU2,KITOZER

Meta Description:KITOZER KTR-PDU2 vertical rack PDU, 16A input, 8x GB 10A outlets, master switch + surge protection, aluminum housing, for cold aisle cabinets.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart