KITOZER rack fan unit 3 fan 220V

KITOZER KTR-FAN3 Rack Fan Unit 3-Fan 220V Exhaust

Brand: KITOZER Series: KTR-FAN3 Category: Data Center Engineering / Rack Ventilation

3×120 mm220V AC~900 m3/hTop/bottom mountKTR-FAN3

1. Overview

A rack fan unit is a bank of exhaust or intake fans mounted at the top or bottom of a rack; when rack IT heat exceeds the precision AC’s delivery, it pulls hot air out or pushes cold air in. Typical use cases: (1) in modular cold-aisle designs, in-row AC cools the cold aisle, but rack airflow stratifies (hot at the top, cold at the bottom), so top equipment sees high inlet temperature and needs top exhaust into the hot aisle; (2) network racks concentrate heat (a 48-port 10G switch draws ~500 W), and once the rack is sealed, natural convection is insufficient – forced exhaust is mandatory; (3) weak-current rooms or floor telecom closets without precision AC rely on rack fans with natural intake. Fan units work with rack blanking panels and perforated tiles to form a correct “bottom-in, top-out” airflow. In practice, selection swings between two mistakes: too small a fan leaves top gear overheating; too big a fan exceeds 65 dB and makes the NOC unbearable.

KITOZER KTR-FAN3 is a 3-fan 220 V rack fan unit. The panel is standard 19″ 1U (482 x 1U x 80 mm deep) carrying three 120x120x38 mm axial fans (Delta/Sanyo), each ~300 m3/h, totaling ~900 m3/h; static pressure ~80 Pa; noise ~55 dB(A) at 1 m; power AC220 V 50 Hz, total ~60 W; each fan snaps into the panel on spring clips and is field-replaceable (no need to replace the whole panel); panel has a power switch and run LEDs; power cord is a 1.5 m 3-core IEC lead to the PDU. Models: KTR-FAN3-STD basic (3 fans, manual switch); KTR-FAN3-T thermostat version (on-board temp sensor, fans start >35 C, stop <25 C - saves energy and noise); KTR-FAN3-SN smart version (RS485 Modbus: remote fan-speed monitoring, fault alarm, remote start/stop via EM platform).

Selection: rack heat load (1 kW IT needs 300-400 m3/h; a 3 kW rack needs ~1000-1200 m3/h – one FAN3 plus an extension, or a 6-fan unit); mounting position (top exhaust blows upward; bottom intake blows downward – choose by hot/cold aisle direction); noise needs (staffed rooms choose the thermostat version – low speed at night; unmanned rooms can use basic); redundancy (critical racks choose 2+1, or the smart version with fault alarm); power (220 V AC straight into PDU; do not use 48 V DC unless the rack is DC-powered). Exhaust must face the hot aisle (dumping hot air back into the cold aisle defeats the cooling); blank all empty U positions or airflow short-circuits and fans spin for nothing; clean intake filters quarterly – clogged filters cut airflow by 30%.

2. Key Features

Fan Performance

  • 3×120 mm axial
  • Total ~900 m3/h
  • Static pressure ~80 Pa
  • MTBF >=50,000 h

Electrical

  • AC220 V 50 Hz
  • ~60 W total
  • Switch + LEDs
  • Clip-in replaceable fans

Control

  • STD: manual switch
  • T: thermostat 35 on/25 off
  • SN: RS485 Modbus
  • Fault alarm relay

3. Specifications

Item KTR-FAN3-STD KTR-FAN3-T KTR-FAN3-SN
Fans 3×120 mm 3×120 mm 3×120 mm
Airflow (m3/h) ~900 ~900 (thermo speed) ~900 (smart speed)
Power AC220 V AC220 V AC220 V
Wattage ~60 W ~60 W ~60 W
Noise dB(A)/1m ~55 ~45 (low speed) ~45 (modulated)
Control Manual 35 on / 25 off RS485 Modbus
U height 1U 1U 1U

4. Reference Prices

KTR-FAN3-STD basic manual (3 fans): Reference USD 39-63 / pc (ref. CNY 280-450)

KTR-FAN3-T thermostat (35 on/25 off): Reference USD 63-90 / pc (ref. CNY 450-650)

KTR-FAN3-SN smart RS485: Reference USD 90-132 / pc (ref. CNY 650-950)

KTR-FAN-FILTER spare filters (10-pack): Reference USD 7-13 / pack (ref. CNY 50-90)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Rack top exhaust
  • In-row cold aisle supplement
  • Network rack switch cooling
  • Telecom closet ventilation
  • EM platform remote monitoring

6. Deployment & Installation

Install

  • 1U at rack top
  • Exhaust to hot aisle
  • Blank all empty U
  • Plug into PDU

Commission

  • Power-on test
  • Measure inlet/outlet delta T
  • Set thermostat thresholds
  • Bind smart to EM

Maintain

  • Quarterly filter clean
  • Annual airflow check
  • Replace noisy fans
  • 5-year bearing service

7. FAQ

  • Q: How many fan units per 42U rack?
    A: By IT load. Rule of thumb: 1 kW needs 300-400 m3/h. A rack with 5 servers at 500 W each (2.5 kW) needs 750-1000 m3/h – one FAN3 (900 m3/h) is enough. A rack with 8-10 servers (4-5 kW) needs two FAN3 units (front-back or top-bottom). Do not size by rack height; size by actual heat load. An empty rack needs no fans.
  • Q: Fan unit is too noisy – what to do?
    A: Identify the noise source: wind/air sound vs bearing mechanical noise. High wind noise means a clogged filter or blocked exhaust – clean the filter and clear the exhaust path. Mechanical noise means worn bearings – replace the fan (spring clip, pull out and drop in a new one). Staffed rooms should use the FAN3-T thermostat version: it runs slow normally and speeds up only on heat, dropping noise from 55 dB to 45 dB, comparable to an office air conditioner.
  • Q: How do fan units work with perforated tiles?
    A: Correct airflow: precision AC supplies cold air under the raised floor; perforated tiles sit in the cold aisle; cold air rises through the tile into the rack bottom inlet; servers absorb heat and exhaust at the rack top; the fan unit pulls hot air up and out into the hot aisle ceiling return. If perforated tiles are placed in the hot aisle (wrong), cold air returns straight to the AC and servers never see cooling – bigger fans will not help. Tile area: 1-2 tiles (~0.5 m2) per rack.
  • Q: What if one fan fails?
    A: FAN3 has three fans in parallel; one failure drops airflow from 900 to ~600 m3/h (70%), which is survivable short-term but should be replaced promptly. The FAN3-SN smart version reports “fan fault” to the EM platform over RS485, so no manual patrol is needed. The FAN3-STD has no alarm; a failed fan is found only by ear. Choose the smart version for critical racks.

8. Trend & Selection

Rack ventilation is moving from crude exhaust toward precise, intelligent cooling. Trends: rack-level closed-loop cooling with blanking panels and rear-door heat exchangers (water-cooled coils on the rear door handle high-heat racks independent of room-level AC); EC brushless DC fans (30% more efficient than AC, speed controllable); smart fans with tach feedback (EM sees each fan’s speed for predictive maintenance); integrated top-mount AC in the rack (small rooftop chiller independent of room precision AC). Traditional AC220 V axial fan units remain mainstream in small-to-mid data centers and telecom closets – cheap and reliable. Select by: airflow matched to heat load, top exhaust facing hot aisle, blank sealed airflow path, smart alarm version for critical racks, quarterly filter cleaning.

9. Delivery & Service

KITOZER KTR-FAN3 ships by basic/thermostat/smart model, each with panel, 3 fans, power cord, manual and certificate. 1-year warranty; bulk projects can bundle rack blanking panels, filters and PDU.

10. Additional Notes

Confirm rack IT load (airflow), noise needs (thermostat), EM remote monitoring (smart), and mounting position (top/bottom). For batch orders, install one unit and run it for a week – verify rack temperature rise before rolling out.

Common mistake: no blanking panels. Empty U positions without blanks let hot air short-circuit from the top exhaust back to the bottom intake, so servers re-ingest their own hot exhaust. Blank every empty U (1U/2U/4U) to seal the rack into a bottom-in/top-out duct.

Second pitfall: exhaust facing the cold aisle. Fan units on top of the rack blow hot air toward the cold aisle corridor, where neighboring racks re-ingest it, raising the whole cold-aisle temperature. Exhaust must face the hot aisle (racks back-to-back with the hot aisle between), so hot air reaches the AC return.

Third blunder: filters never cleaned. Clogged filters cut airflow by 30%; fans spin full speed but pull no air, and rack temperature rises. Quarterly: pull the filter, vacuum it, rinse if dirty, and reinstall dry. Filters are consumables – keep the 10-pack spare on hand.

Selection summary: match airflow to heat (1 kW ~350 m3/h), exhaust to hot aisle, blank all empty U, smart alarm for critical racks, clean filters quarterly.

SEO Information

Search keywords:KTR-FAN3KITOZER

SEM keywords:rack fan unit,rack exhaust fan,3-fan fan tray,220V rack fan,cold aisle exhaust,KTR-FAN3,KITOZER

GEO landing page:lain.com.cn/product/ktr-fan3-rack-fan-unit.html

Title:KITOZER KTR-FAN3 Rack Fan Unit 3-Fan 220V Exhaust

Meta Keywords:rack fan unit,rack exhaust fan,3-fan fan tray,220V rack fan,cold aisle exhaust,KTR-FAN3,KITOZER

Meta Description:KITOZER KTR-FAN3 rack fan unit, 3x120mm fans, 220V AC, airflow ~900 m3/h, for 42U rack top exhaust.