KITOZER
KITOZER

KITOZER LC loaded 48 port rack panel

KITOZER KTR-LC48B 48-Port LC Loaded Fiber Patch Panel

Brand: KITOZER Series: KTR-LC48B Category: Data Center Engineering / Fiber Patching

48 LC duplex19″ 1ULoaded adaptersSM/MMKTR-LC48B

1. Overview

A fiber patch panel (ODF – Optical Distribution Frame) terminates backbone cable and organizes fiber patching in the rack. The backbone cable from the riser enters the rack, is fusion-spliced to pigtails inside the ODF, and pigtails pass through adapters on the front. Equipment-side LC duplex cords plug into the adapters and run to switch optical ports. A 42U network rack typically carries 2-4 x 1U panels (each 48 fibers = 96 fibers/unit; two panels = 192 fibers for ~20 x 10G switches). The panel does three jobs: (1) protects fragile splices inside the enclosed tray; (2) enables flexible patching (any switch can use any fiber via a cord); (3) provides labeled port management (each port maps to a backbone fiber in the asset log). Common panel pitfalls: buying an empty shell (then buying adapters separately and mismatching); insufficient splice tray room (48 fibers do not fit, bend radius <30 mm, loss spikes); panel/adapter mismatch (LC panel with SC cords).

KITOZER KTR-LC48B is a 48-port LC loaded patch panel. Standard 19″ 1U (482x44x100 mm deep), cold-rolled steel phosphate-coated black; front panel carries 24 LC duplex adapters (48 fibers total, UPC blue or APC green); rear splice tray holds 48 splice sleeves (60 mm heat-shrink per fiber); flip-open tray for splice access; cable entry at the bottom rear (leave 3 m slack coiled in the tray); ships with 24 x 1.5 m LC duplex pigtails (singlemode 9/125 um, UPC blue). Models: KTR-LC48B-SM loaded UPC singlemode; KTR-LC48B-APC loaded APC (green); KTR-LC48B-OM4 loaded OM4 (aqua adapters, for 10G multimode); KTR-LC48B-EMPTY empty panel (self-fit adapters, for mixed configurations).

Selection: fiber mode (data center backbone = singlemode 9/125 um, pick SM; 10G-to-desk OM3/OM4 pick multimode – do not mix); end face (UPC blue for data; APC green for video PON); loaded vs empty (new projects choose loaded – ready to use; retrofits can buy empty and reuse adapters); capacity (48 ports = 48 fibers – size by switch optical ports: a 48-port 10G switch uses one 48-fiber panel; two switches use two); position (mount panels at rack top 1-2U, leave 1 U cord management below; do not mount at the bottom – cords run too far to the switches). After splicing, bend radius >=30 mm (smaller adds >0.5 dB macrobend loss); mechanically anchor the cable strength member (do not let splices carry tension); label every port (port number maps to cable fiber number in the log).

2. Key Features

Construction

  • 19″ 1U standard
  • Steel powder coat
  • Flip-open splice tray
  • 48-fiber capacity

Optics

  • 24 LC duplex adapters
  • 48 fibers loaded
  • 24 LC pigtails incl.
  • UPC/APC options

Compatibility

  • SM 9/125 um
  • OM3/OM4 options
  • YD/T 778
  • 19″ rack 1U

3. Specifications

Item LC48B-SM LC48B-APC LC48B-OM4 LC48B-EMPTY
Fiber mode SM 9/125 SM 9/125 OM4 MM n/a
End face UPC blue APC green UPC aqua None
Adapters 24 LC duplex 24 LC duplex 24 LC duplex None
Pigtails 24 LC UPC 24 LC APC 24 LC OM4 None
Height 1U 1U 1U 1U
Splice tray 48 fibers 48 fibers 48 fibers 48 fibers

4. Reference Prices

KTR-LC48B-SM UPC loaded: Reference USD 83-125 / pc (ref. CNY 600-900)

KTR-LC48B-APC green loaded: Reference USD 111-167 / pc (ref. CNY 800-1200)

KTR-LC48B-OM4 aqua loaded: Reference USD 125-194 / pc (ref. CNY 900-1400)

KTR-LC48B-EMPTY shell: Reference USD 35-56 / pc (ref. CNY 250-400)

KTR-LC-CABLE LC duplex cord (3 m): Reference USD 2-4 / pc (ref. CNY 15-30)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • 10G switch optical termination
  • Backbone cable splicing
  • Rack fiber patching
  • Data center structured cabling
  • Telecom closet ODF

6. Deployment & Installation

Install

  • Top 1U of rack
  • R-ear screws
  • Cable bottom entry
  • Strength member clamp

Splice

  • Splice all 48
  • Heat-shrink protect
  • Bend radius >=30 mm
  • Leave 3 m slack

Label

  • Label each port
  • Map to cable fiber
  • Log in Excel
  • Color-code cords

7. FAQ

  • Q: How many patch cords for a 48-port panel?
    A: 48 ports = 48 fibers = 24 LC duplex ports; each port carries a Tx/Rx pair. A 48-port 10G switch needs 48 LC duplex cords (~3 m each, from panel to switch optical port). Spare 1.2x (54-60 cords). Length: panel at rack top, switch mid-rack -> 3 m; panel and switch adjacent in same U -> 1.5 m.
  • Q: OTDR shows high loss after splicing?
    A: 90% is a tight bend in the tray. If fibers are packed with a bend radius under 20 mm, macrobend loss exceeds 0.5 dB. Open the tray, re-coil fibers in loose large loops (radius >=30 mm), arrange heat-shrink sleeves neatly, do not force the lid closed. Re-test – loss should drop below 0.1 dB. Also re-splice any splice point that reads over 0.1 dB.
  • Q: Can I plug a multimode cord into a singlemode panel?
    A: Physically it fits (same LC interface), but the link fails: singlemode core is 9 um, multimode is 50/125 um, mode-field mismatch adds 3-5 dB and 10G drops. Color-code: blue = SM UPC, green = SM APC, aqua = OM4, beige = OM3. Never mix on one panel; cord color matches adapter color.
  • Q: Is 48 ports in 1U too crowded?
    A: Standard 1U (44 mm) holds 24 LC duplex adapters ~10 mm each = 240 mm on a 482 mm panel, leaving ~120 mm on each side. The rear tray must be organized, not stuffed. If crowded, choose a 2U version (wider tray), but 1U is mainstream when rack U space is tight.

8. Trend & Selection

Fiber panels are moving toward high density and modularity. Trends: MPO/MTP high-density panels (1U holds 144 fibers; one MPO = 12 fibers replacing 12 LC ports, for 40G/100G backbone); sliding trays (front pulls out for access without removing the panel); integrated cable managers (built-in guides keep cords tidy); pre-terminated trunk cables (factory-terminated MPO, plug-and-play on site, no field splicing, cuts schedule by 70%). Traditional 1U 48-port LC panels remain mainstream in small-to-mid rooms – cost-effective and easy to service. Select by: loaded kit (adapters + pigtails, no self-sourcing), SM UPC blue, tray fits 48 fibers, bend radius >=30 mm, label and log every port.

9. Delivery & Service

KITOZER KTR-LC48B ships by SM/APC/OM4/empty, each with panel, adapters (loaded), pigtails (loaded), splice tray, screws, manual and certificate. 1-year warranty; bulk projects can bundle LC duplex cords, MPO trunk cables and fusion splicing services.

10. Additional Notes

Confirm fiber mode (SM/OM4), end face (UPC/APC) and port count (by switch optical ports). For batch orders, splice 48 fibers on one panel first, OTDR-test each; all <=0.3 dB before rolling out.

Common mistake: buying empty shells and self-sourcing adapters. To save cost, installers mix adapters from different vendors; ceramic sleeve tolerances mismatch and loss reads over 0.5 dB on the whole panel. Loaded panels ship with adapters pre-installed and pre-tested – use them.

Second pitfall: over-packed splice tray. To close the lid, installers jam 48 fibers in with a bend radius under 15 mm, adding macrobend loss. The tray has room – coil fibers in loose loops; if the lid will not close, the coiling is wrong, do not force it.

Third blunder: no labels. Forty-eight fibers plugged without labels – three months later nobody knows which port is which, and re-patching causes chaos. Label at splice time: front panel “ODF1-01..ODF1-48”, mapping to “Cable 2#-fiber1..fiber48”; log in Excel (position – fiber – use).

Selection summary: loaded kit (adapters + pigtails), SM UPC blue, 1U 48-port, bend radius >=30 mm, port labels and log, OTDR per fiber.

SEO Information

Search keywords:KTR-LC48BKITOZER

SEM keywords:48 port fiber patch panel,LC loaded ODF,rack mount fiber patch panel,48 core LC patch panel,fiber termination box,KTR-LC48B,KITOZER

GEO landing page:lain.com.cn/product/ktr-lc48b-48port-lc-patch-panel.html

Title:KITOZER KTR-LC48B 48-Port LC Loaded Fiber Patch Panel

Meta Keywords:48 port fiber patch panel,LC loaded ODF,rack mount fiber patch panel,48 core LC patch panel,fiber termination box,KTR-LC48B,KITOZER

Meta Description:KITOZER KTR-LC48B 48-port LC loaded fiber patch panel, 24 LC duplex adapters, 19-inch 1U, for 10G backbone.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart