Table of Contents
ToggleKITOZER KTR-TH3 Wall-Mount Temp/Humidity Display Ethernet
Brand: KITOZER Series: KTR-TH3 Category: Environmental Monitoring / Wall Display
Large LCDEthernet TCP/IP+/-0.3 CWall mountKTR-TH3

1. Overview
A wall-mount temp/humidity display is a large-panel device hung outside the NOC or in the corridor, so operators see room conditions at a glance without logging into the EM platform. It differs from a regular RS485 sensor (KTR-THS2) in four ways: (1) a large display (4-5 inch LCD, digit height 30 mm, readable from 3 m); (2) Ethernet (direct RJ45 to the switch – no RS485 bus or gateway, easy for scattered points); (3) audible/visual alarm (screen turns red + buzzer on threshold, so staff hear it without staring); (4) larger housing (200x120x30 mm, not a small 86-box). Typical placement: one outside the NOC door (check before entering), one at each cold-aisle entrance for walk-by patrol, one at the battery-room door (battery life halves above 30 C). EM platforms require login; the wall display solves the “you have to log in to see it” problem and cuts response time.
KITOZER KTR-TH3 is a wall-mount temp/humidity sensor with a large LCD. Core is a Sensirion calibrated digital chip: temp -20 to +60 C, +/-0.3 C; humidity 0-100% RH, +/-3% RH. Display: 4-inch segment LCD (100×60 mm active area) showing temp (large digits) + humidity (smaller) + time/date. Communication: RJ45 Ethernet TCP/IP with built-in web server (browse to the IP, no software); also RS485 Modbus as a backup path to the EM platform. Power: DC12 V (adapter included) or PoE 802.3af (PoE model: one cable for power+data). Alarm: on temp >27 C or <18 C, humidity >65% or <40% RH, screen backlight turns red and an 85 dB buzzer beeps (muteable). Housing 200x120x30 mm on an 86-box wall base. Three buttons (set/up/down) configure thresholds and IP on site. Models: KTR-TH3-LAN RJ45 Ethernet; KTR-TH3-POE PoE; KTR-TH3-4G wireless (SIM, cloud platform, for old buildings without cable); KTR-TH3-BIG 7-inch color touchscreen (history curves and multi-channel).
Selection: comm method (Ethernet/PoE if cable exists; 4G if not); power (new projects: PoE, one cable; retrofits: 12 V adapter); display size (4-inch is fine outside the NOC; 7-inch color for the lobby); alarm type (staffed rooms keep buzzer; unmanned rooms use screen-only + EM SMS); mounting height (eye level 1.5-1.6 m, facing the door, out of direct sunlight). Do not mount under an AC vent (measures cold air, not room ambient); avoid the door (door openings swing outdoor air in and readings jitter); PoE cable under 90 m; 4G needs cellular signal (basements need an external antenna).
2. Key Features
Sensing & Display
- +/-0.3 C
- +/-3% RH
- 4-inch segment LCD
- Readable at 3 m
Comm
- RJ45 TCP/IP
- Built-in web UI
- RS485 Modbus backup
- Optional 4G
Alarm & Power
- Red backlight alarm
- 85 dB buzzer
- DC12 V / PoE
- 86-box wall mount
3. Specifications
| Item | TH3-LAN | TH3-POE | TH3-4G | TH3-BIG |
|---|---|---|---|---|
| Display | 4-inch seg | 4-inch seg | 4-inch seg | 7-inch TFT |
| Comm | RJ45 TCP/IP | RJ45 PoE | 4G LTE | RJ45 TCP/IP |
| Temp acc. | +/-0.3 C | +/-0.3 C | +/-0.5 C | +/-0.3 C |
| Hum acc. | +/-3% RH | +/-3% RH | +/-5% RH | +/-3% RH |
| Power | DC12 V | PoE af | DC12 V | PoE/DC12 |
| Alarm | Red+buzzer | Red+buzzer | Red only | Red+buzzer |
4. Reference Prices
KTR-TH3-LAN Ethernet RJ45: Reference USD 39-63 / pc (ref. CNY 280-450)
KTR-TH3-POE PoE: Reference USD 49-76 / pc (ref. CNY 350-550)
KTR-TH3-4G cloud: Reference USD 69-111 / pc (ref. CNY 500-800)
KTR-TH3-BIG 7-inch color: Reference USD 111-181 / pc (ref. CNY 800-1300)
KTR-TH3-ADAPTER DC12 V PSU: Reference USD 3-6 / pc (ref. CNY 20-40)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- NOC door board
- Cold-aisle patrol display
- Battery room door temp
- Archive/store room public display
- Unmanned station visibility
6. Deployment & Installation
Mount
- 1.5 m eye level
- Facing corridor/door
- Avoid direct sun
- 86-box base
Network
- Static unique IP
- Browse to IP for data
- Bind to EM platform
- RS485 backup
Alarm
- Hi 27 C / Lo 18 C
- RH 65% / 40%
- Buzzer muteable
- Red backlight on alarm
7. FAQ
- Q: TH3 vs THS2 – which to choose?
A: THS2 is an 86-box (86×86 mm) that only uploads to EM, no local display. TH3 is a large wall panel (200×120 mm) with a 4-inch LCD, for NOCs and corridors. THS2 runs RS485 buses (32 per bus); TH3 uses Ethernet (one IP each, a dedicated cable to the switch) – simple for scattered points but one cord per unit. Fewer points (3-5): choose TH3 Ethernet. Many points (20+): choose THS2 RS485. - Q: Where does the 4G version send data?
A: The 4G version has a built-in IoT SIM; data uploads every 30 s to the KITOZER cloud (WeChat mini-app or web), no server to buy. For old buildings, container rooms or outdoor cabinets. Note: 4G has a yearly data fee (~30 CNY/year/unit) – confirm 3 years of data is included. Basements with weak signal need an external suction-cup antenna on a 5 m lead out a window. - Q: Buzzer too loud at night?
A: Press “Set” to enter alarm config and mute the buzzer (keep the red screen). NOC-door units should keep the buzzer on (someone hears it); corridors and unmanned battery rooms can mute and rely on EM SMS. The red screen is hardware backlight and cannot be disabled by design – passersby should see it. - Q: Does sunlight wash out the display?
A: Segment LCD contrast drops in direct sun. Mount on the shaded side (not opposite a window), or add the KTR-TH3-SHADE plastic visor. Data centers usually have no windows; if the panel is next to a glass partition, watch for west-afternoon glare. The 7-inch TFT has adjustable backlight and handles sunlight better.
8. Trend & Selection
Wall displays are evolving from single-point readouts to multi-function boards. Trends: color screens (4-inch segment -> 7-inch TFT with history curves, multi-channel data, EM alarm lists); PoE + Wi-Fi dual interface (PoE powers, Wi-Fi backs up if Ethernet drops); USB export (30-day local storage, plug in a stick for Excel audit); e-paper (ultra-low power, readable in sun, for warehouses/archives); access-control linkage (swiping a card shows that zone’s temp/humidity history). Traditional segment LCD remains mainstream in small-to-mid NOCs – cheap and reliable. Select by: Ethernet/PoE, 4-inch readable at 3 m, audible/visual alarm, 1.5 m eye level, away from vents and sun, per-point IP uniqueness.
9. Delivery & Service
KITOZER KTR-TH3 ships by LAN/PoE/4G/color, each with sensor, wall base, PSU (LAN), patch cord, manual and certificate. 1-year warranty; bulk projects can bundle PoE switches, EM integration software and visors.
10. Additional Notes
Confirm comm (Ethernet/PoE/4G), display size (4-inch segment / 7-inch color), audible alarm, and mounting position. For batch orders, mount one, browse to its IP, verify data, then roll out.
Common mistake: mounting under an AC vent. The screen reads 23 C “all normal” while the rack is at 30 C – because the sensor sees cold supply air, not room ambient. Mount at the cold-aisle inlet, 1-2 m from the vent.
Second pitfall: powering up without setting IP. Multiple units all use the factory default 192.168.1.100, causing IP conflict and unresponsive web UIs. At install, set a unique IP per unit (192.168.1.101, 102, 103) and log them.
Third blunder: buzzer unmuted at night. Thresholds set too low trigger the buzzer at 26 C through the night, disturbing staff. Set temp upper at 27 C (not 25 C), lower at 18 C, humidity 40-65% – within normal operating range.
Selection summary: Ethernet/PoE, 4-inch large display, audible/visual alarm, 1.5 m eye level, away from vents and sun, unique IP per unit.
SEO Information
Search keywords:KTR-TH3KITOZER
SEM keywords:wall mount temp humidity sensor,LCD temp humidity display,Ethernet temp sensor,room temp display,KTR-TH3,KITOZER
GEO landing page:lain.com.cn/product/ktr-th3-wall-mount-temp-humidity-display.html
Title:KITOZER KTR-TH3 Wall-Mount Temp/Humidity Display Ethernet
Meta Keywords:wall mount temp humidity sensor,LCD temp humidity display,Ethernet temp sensor,room temp display,KTR-TH3,KITOZER